Catalog: HVAC & Refrigeration Product Catalog
Company/Brand: Bacharach
vac 50 in HVAC & Refrigeration Product Catalog by Bacharach
r-407a r-407c r-408a r-409a r-410a r-500 r-502 r-503 r-507 r-508b h-1211 h-1301 ... range weight 4 to 122°f 20 to 50°c 18 lbs 8.2 kg 5 to 90 rh non condensing ... 32 to 122°f 0 to 50°c 3015-4417 3015-1486 3015-1018 100 to ... 240 vac 50/60 hz 15 watts 4 h x 10.75 w x 15 d 10. ...
refrigerants power source compressor vacuum rating high pressure limit recovery ... except r-11 r-113 and r-123 115 vac 50/60 hz 230 vac 50/60 hz 100 vac 50/60 hz ... oil-less 13 hg 450 psi 31.0 bar .50 4.0 lbs min vapor 8.0 lbs min liquid 0 ... refrigerants power source compressor vacuum rating high pressure limit recovery ... except r-11 r-113 and r-123 115 vac 50/60 hz 230 vac 50/60 hz 100 vac 50/60 hz ... refrigerants power source compressor vacuum rating high pressure limit recovery ... except r-11 r-113 and r-123 115 vac 50/60 hz 230 vac 50/60 hz 100 vac 50/60 hz ...

stinger is capable of pulling a vacuum for an extended period of time without ... r-409a r-410a r-411a r-411b r-412a r-500a r-502b r-507 r-509 power source also ... available compressor type vacuum rating high pressure limit r-22 ... approvals certifications 110/120 vac 1 phase 50/60 hz 8 amps 220 vac 1 phase ... 50/60 hz 4 amps 0.8 hp high performance ... -0091 2007-0080 description stinger 115 vac stinger 115 vac w 80 shut-off stinger ... 230 vac 50/60 hz 80 shut-off kit carrying strap 38 ...

model cfc hfc r-11 r-12 r-113 r-114 r-502 r-404a hp62 r-407a r-407c ac9000 r- ... 134a r-410a az20 r-507 az50 r-508b suva95 code b -11 -12 -13 -14 code c -1 ... type 120vac 60 hz standard 240vac 50 hz export applications only 240vac 60 ... refrigeration hcfc r-22 r-123 r-124 r-500 r-503 r-401a mp39 r-402a hp80 r-40b ... in 4 point increments 3 spdt 5 amp 240 vac rated alarm relays and 1 spdt 5 amp 240 ... vac rated system fault relay plus a digital ... tube length and gas concentration up to 500 feet from measuring point to monitor ... 120 vac 60 hz standard 240 vac 50 hz export 240 vac 60 hz domestic 17 l ... rdm800 120vac 60 hz rdm800 240vac 50/60 hz adm800 120vac 60 hz adm800 ... 240vac 50/60 hz detector type sensitivity hgm300 ...

monitor includes termination filter and 50ft of 3042743 sample /exhaust purge line ... line tubing termination filter 120 vac surge protector 220 vac surge protector ... 4-20ma surge protector 120 vac external visual alarm 120 vac external ... audible alarm 120 vac external audible visual alarm hgmsz ... r-407a r-407c r-408a r-409a r-410a r-500 r-502 r-503 r-507 r-508b h-1211 h-1301 ... dedicated single zone 3 spdt 5 amp 240 vac rated alarm relays and 1spdt 5 amp 240 ... vac rated system fault relay plus a digital ... on sample tube length 120 to 240 vac 50/60 hz 14 w x 18 l x 4.5 d 7lbs 35. ... 4cm/3.2kg max monitoring distance up to 50 feet from measuring point to monitor 42 ...

monitor includes 1 termination filter 50ft of 304-2742 sample line tubing and 50ft ... is required for agmsz sample line 120 vac surge protector 220 vac surge protector ... 4-20ma surge protector 120 vac external audible alarm 120 vac external ... visual alarm 120 vac external audible visual alarm ag m s z ... dedicated single zone 3 spdt 5 amp 240 vac rated alarm relays and 1spdt 5 amp 240 ... vac rated system fault relay plus a digital ... on sample tube length 120 to 240 vac 50/60 hz 14 x 18 x 4.5 7 lbs 35.6cm x ... 3.2kg max monitoring distance up to 50 feet from measuring point to monitor ...