Bus Terminal 2017 by Beckhoff Automation

More catalogs by Beckhoff Automation | Bus Terminal 2017 | 144 pages | 2017-09-16

Ads

Contacts for Beckhoff Automation

Beckhoff Automation GmbH
Eiserstraße 5
33415 Verl
Germany

Telefon: + 49 (0) 52 46 / 9 63 - 0
Fax: + 49 (0) 52 46 / 9 63 - 1 98
info@beckhoff.de
http://www.beckhoff.com/

Catalog Bus Terminal 2017

electronic terminal blocks spring loaded terminal strips terminal blocks with resisters 28 awg stranded wire flat ribbon cable flat ribbon cable 1 pulse width module pulse width modulator pulse width modulation 14 stranded wire 9 pin d sub connector motor protection relay flat ribbon cable 6 pin flat ribbon cable 3 pin 9 pin flat ribbon cable flat ribbon cable 4 pin flat ribbon cable 5 pin flat ribbon cable 9 pin flat ribbon cable 7 pin motor protection relays 6 pin flat ribbon cable flat ribbon cable connectors flat ribbon cable connector 28 awg flat ribbon cable stepper motor speed controller flat ribbon cable 15 18 awg flat ribbon cable flat ribbon cable 9 pin connector flat ribbon cable 4 pin connector flat ribbon cable 6 pin connector flat ribbon cable 8 pin connector flat ribbon cable 5 pin connector flat ribbon cable 24 pin 100 pin d sub connector bnc female connector flat ribbon cable 14 16 awg flat ribbon cable flat ribbon cable 100 pin flat ribbon cable 15 pin flat ribbon cable 60 pin flat ribbon cable 50 pin 15 pin flat ribbon cable flat ribbon cable 18 pin flat ribbon cable 12 pin flat ribbon cable 14 pin flat ribbon cable 30 pin flat ribbon cable 25 pin flat ribbon cable 15 pin connector flat ribbon cable 16 pin connector flat ribbon cable 13 pin 14 pin flat ribbon cable flat ribbon cable 12 connector flat ribbon cable 60 pin connector flat ribbon cable 11 pin 24 dc motor speed controller

Bus Terminal 2017 is listed under these categories

Industrial Supply > Industrial Automation

Featured catalog pages of Bus Terminal 2017

bcxx20 bxxx00 cx80xx cx9xxx cx9020 cx50xx fieldbus slave fieldbus slave embedded pc embedded pc embedded pc embedded pc with integrated with integrated fieldbus slave fieldbus slave fieldbus slave fieldbus slave iec 61131-3 plc iec 61131-3 plc with integrated with integrated with integrated with integrated iec 61131-3 plc iec 61131-3 plc iec 61131-3 plc iec 61131-3 plc motion control motion control motion control visualisation visualisation visualisation – – – 128 kbyte 256 kbyte – bus terminal embedded pc 573 – – 64 mbyte ddr2 64…128 mbyte sdram 1 gbyte ddr3 ram 512 mbyte ddr2 1750 ma 1450 ma 2000 ma 2000 ma 2000 ma 2000 ma plug design plug design plug design – optional plug optional plug depends on depends on depends on design depends design depends the fieldbus the fieldbus the fieldbus on the fieldbus on the fi eldbus all all all all all all 64 255 with 64 255 with 64 255 with 64 255 with 64 255 with 64 255 with terminal bus

bus coupler housing technical data – bus coupler housing 46 mm 18 mm 100 mm 100 mm 100 mm 47 mm 42 mm 49 mm 44 mm bkxxxx bcxxxx bkxx50 bcxx50 21 mm 81 mm bxxxxx lcxxxx mechanical data bkxxxx bcxxxx bkxx50 bcxx50 bxxxxx lcxxxx bc9191 design form compact terminal compact terminal compact terminal compact terminal compact controller housing with signal housing with signal housing with signal housing with signal led led led led material polycarbonate polycarbonate polycarbonate polycarbonate pc/abs dimensions w xhxd 49 mm x 100 mm x 44 mm x 100 mm x 81 mm x 100 mm x 21 mm x 100 mm x 118 mm 127 mm 68 mm 68 mm 89 mm 68 mm with end cap and bx8000 61 mm x din rail mounting x 100 mm x 89 mm 100 mm x 70 mm installation on 35 mm din rail conforming to en 60715 with lock side by side mounting double slot and key connection by means of marking standard terminal standard terminal standard terminal standard terminal connection points block marking block marking block marking block marking on

bk7300 bk7350 standard modbus bus coupler modbus “compact” bus coupler for up to 64 bus terminals for up to 64 bus terminals modbus 255 with k-bus extension bk7300 bk7350 64 64 255 with k-bus extension 512 byte input and 512 byte output 1750 ma 1000 ma +60 °c the bk7300 bus coupler connects the modbus bus system to the modular extendable electronic terminal blocks one unit consists of one bus coupler any number from 1 to 64 terminals and one end terminal the “compact” bk7350 bus coupler is a cost-optimised version with compact housing with the k-bus extension up to 255 bus terminals can be connected d-sub 9-pin rs485 d-sub 9-pin rs485 150 baud…38,400 baud 150 baud…38,400 baud approx 170 g approx 100 g 0…+55 °c -25…+60 °c ce ul ex gl ce ul ex www.beckhoff.com/bk7300 www.beckhoff.com/bk7350 see page – we reserve the right to make technical changes 800 see page – 800 bus terminal -25 °c

bx9000 bc9191 ethernet ethernet room controller ethernet bus terminal controller building automation room controller building automation room controller for up to 64 bus terminals 48 kbyte sub bus for kl6583 enocean 128 kbyte rs485 interface bx9000 bc9191 bc9191-0100 64 255 with k-bus extension 64 255 with k-bus extension 512 byte input and 512 byte output 200 ma digital inputs 3 contacts e.g window contact dew point occupancy sensor analog inputs 1 x pt/ni1000 1 x resistance measurement for set point 3 x 0…10 v digital outputs 1 x led 10 ma 1 x 230 v ac 10 a relay 3 x 230 v ac 1 a relay 2 x 230 v ac 1 a triac analog outputs 2 x 0…10 v the bx9000 bus terminal controller has an ethernet slave/master interface the controller has automatic baud rate detection up to 100 mbaud the address can optionally be entered via dhcp bootp arp or with the joystick switch the bc9191 and bc9191-0100 ethernet room controllers cover the standard functionalities for room control in a compact

kl13xx digital input 2-channel digital input 2-channel digital input 2-channel digital input terminal 24 v dc terminal 24 v dc terminal 24 v dc for break-in alarm thermistor for namur sensors kl1362 ks1362 kl1382 ks1382 kl1352 ks1352 thermistor ptc namur 2-wire break-in alarm 3.0 ms 30 ms 3.0 ms 2 2 2 +60 °c -25 °c 1 5 1 5 1 +5 v 2 4.7 k 6 2 5 +8.2 v 6 2 6 7 3 7 8 4 10 k υ υ 1k 4.7 k 7 3 8 4 4 alarm sensor equivalent circuit alarm sensor the digital kl1362 input terminal analyses the input signals of break-in sensors with the aid of a current loop it enables safe monitoring of alarm contacts with fixed resistance ratio in the process image the state of the sensor is indicated by one bit each a further bit reports short circuits or line interruptions – – – line interruption 0.1 ma short circuit 3 ma cable resistance ≤ 200 Ω ptc sensor equivalent circuit ptc sensor the digital kl1382 input terminal analyses the input signal of

km2642 km2652 2-channel relay module 2-channel relay module 230 v ac manual/automatic 230 v ac manual/automatic operation operation km2642 km2652 digital output 2 x change-over 2 x change-over the digital km2642 output terminal has two independent relay change-over contacts which can be used for switching mains current consumers for each channel a switch enables selection between automatic manual on manual off in automatic mode the logical state of an output bit switches the relay for manual mode a 24 v supply is required for the bus coupler the output state can be read by the controller the digital km2652 output terminal has two independent relay change-over contacts which can be used for switching mains current consumers for each channel a switch enables selection between automatic manual on manual off in automatic mode the logical state of an output bit switches the relay for manual mode a 24 v supply is required for the bus coupler the state of the output and the switch can be

kl340x kl31xx analog input 4-channel analog 8-channel analog 2-channel analog 2-channel analog input terminal input terminal input terminal input terminal -10…+10 v 12 bit -10…+10 v 12 bit -10…+10 v 16 bit -10…+10 v 16 bit single-ended single-ended differential input differential input kl3404 ks3404 kl3408 ks3408 kl3102 ks3102 kl3132 ks3132 16 bit for 0…10 v range resolution 15 bit single-ended single-ended differential input differential input 2 ms 4 ms 140 ms configurable to 2 ms 140 ms configurable 4 8 2 2 +60 °c 1 5 2 6 3 7 4 8 1 5 1 5 1 5 +24 v 2 6 2 6 2 6 0v 3 7 3 7 3 7 4 8 4 8 4 8 the kl3404 analog input terminal has four inputs which are implemented in 2-wire technique the common reference ground of the inputs is the internal ground the kl3408 analog input terminal combines eight inputs in one housing the use of single conductor connection technology enables the connection of multi-channel sensor technology with minimum space

kl3681 analog input analog input digital multimeter digital multimeter terminal technical data kl3681 ks3681 measuring voltage 300 mv 3 v 30 v 300 v resolution 18 bit sign in each measurement range technology digital multimeter with automatic range selection update time 0.5 s 1 s for measuring range selection number of inputs 1 voltage or 1 current 10 a/1 a 5 12.5 m 1 6 3 7 4 8 bus terminal 0.2 2 3m the kl3681 bus terminal enables measurement of currents and voltages in a wide input range the measuring ranges are switched automatically as usual in advanced digital multimeters there are two current paths available for current measurement one of them is a high current path for up to 10 a the current and the voltage measurement facility can be used for dc and ac the alternating parameters are output as true rms values the measurement readings can be read and processed with commercially available fieldbuses at the same time the kl3681 enables the measuring type and range to be set via

kl5111 kl515x position measurement 1-channel incremental encoder interface 1-channel incremental encoder interface 2-channel incremental encoder interface 16 bit single-ended 24 v dc 32 bit single-ended 24 v dc 32 bit single-ended 24 v dc kl5111 ks5111 kl5151 ks5151 kl5152 ks5152 incremental encoder interface 24 v dc en 61131-2 type 1 “0” 5 v dc ”1” 15 v dc typ 5 ma 1 incremental encoder 2 incremental encoders a b c 24 v low 3 v high 18 v a b c gate/latch 24 v a1 b1 a2 b2 24 v +60 °c 1 5 1 5 1 5 2 6 2 6 2 6 3 7 3 7 3 7 4 8 4 8 4 8 the kl5111 bus terminal is an interface for the direct connection of 24 v incremental encoders a 16 bit counter with a quadrature decoder and a 16 bit latch for the zero pulse can be read set or enabled the state of the counter is transmitted quickly and securely to the pc plc or cnc over the fieldbus interval measurement with a resolution of 200 ns is possible the kl5151 bus terminal is an interface with 24 v inputs for the

kl90xx kl9195 system terminals system terminals function terminals shield shield separation terminal terminal terminal technical data kl9070 kl9195 ks9195 kl9080 technology shield terminal diagnostics in the – separation terminal process image +60 °c -25 °c 1 5 1 5 2 6 2 6 3 7 3 7 4 8 4 8 bus terminal the kl9195 bus terminal can be used for the connection of screens the kl9195 connects the spring force contacts directly to the din rail and can optimally ground incoming electromagnetic radiation the two power contacts are looped through by the kl9195 allowing two wires to be connected to each power contact the kl9010 bus end terminal is necessary for data exchange between the bus coupler and the bus terminals each assembly must be terminated at the right hand end with a kl9010 bus end terminal the bus end terminal does not have any other function or connection facility the kl9080 is used to identify potential groups e.g 230 v ac/24 v dc it is inserted between two

special terminals kl3312-0022 type s kl3312-0023 type s in siemens s5 format kl3312-0024 type t kl3312-0025 type t in siemens s5 format kl3312-0026 type u kl3312-0027 type u in siemens s5 format kl3312-0028 0…120 mv measurement kl3312-0029 type k in siemens s5 format kl3312-0040 expanded temperature range for type s and l type s -50…+1700 °c as supplied type l -100…+900 °c kl3312-0110 type j fahrenheit scaling kl3312-2000 setting of reference junction temperature via process image unit 1/256° c in a 16 bit word kl3312-2100 external reference point temperature specification via process image is possible the unit is 1/256 °c in 16-bit format fast conversion time 65 ms kl3351-0001 1-channel resistor bridge terminal strain gauge with faster measurement time approx 10 ms kl3403-0010 3-phase power measurement terminal current path designed for 5 a transducer 1 measuring accuracy i kl3403-0020 3-phase power measurement terminal current path designed for 20 ma