addison pvc insulated jumper wires to cw 1109 cw 1257 cw 1423 096 indoor switchboard telephone cables to cw 1293 099 indoor central office cables to cw 1308 104 pe insulated lszh sheathed cables to cw 1600 108 pvc/lszh insulated pvc/lszh sheathed switchboard cables to din vde 0815 111 pe insulated pvc/lszh sheathed installation cables to din vde 0816/0815 114 pvc insulated pvc sheathed installation cables to din vde 0815/din 57815 117 sr insulated lszh sheathed fire resistant cables to din vde 0815 119 mica/lszh insulated lszh sheathed fire resistant cables to din vde 0815 122 indoor/outdoor telephone cables pe insulated category 3 utp/ftp cables 126 special telephone cables adsl connecting cables 130 xdsl connecting cables 132 pe insulated isdn primary access air core cables 134 pe insulated isdn basic access air core cables 136 pe insulated air core/jelly filled paired railway signalling cables rf 0.3 138 pe insulated air core/jelly filled star qu
|
caledonian www.caledonian-cables.co.uk continued from previous page cable code tp816a-2yfl2y-stiii-bd-120p04 tp816a-2yfl2y-stiii-bd-150p04 tp816a-2yfl2y-stiii-bd-200p04 tp816a-2yfl2y-stiii-bd-250p04 tp816a-2yfl2y-stiii-bd-300p04 tp816a-2yfl2y-stiii-bd-350p04 tp816a-2yfl2y-stiii-bd-400p04 tp816a-2yfl2y-stiii-bd-500p04 tp816a-2yfl2y-stiii-bd-600p04 tp816a-2yfl2y-stiii-bd-700p04 tp816a-2yfl2y-stiii-bd-800p04 tp816a-2yfl2y-stiii-bd-1000p04 tp816a-2yfl2y-stiii-bd-1200p04 tp816a-2yfl2y-stiii-bd-1500p04 tp816a-2yfl2y-stiii-bd-2000p04 tp816a-2yfl2y-stiii-bd-6p06 tp816a-2yfl2y-stiii-bd-10p06 tp816a-2yfl2y-stiii-bd-20p06 tp816a-2yfl2y-stiii-bd-30p06 tp816a-2yfl2y-stiii-bd-40p06 tp816a-2yfl2y-stiii-bd-50p06 tp816a-2yfl2y-stiii-bd-70p06 tp816a-2yfl2y-stiii-bd-100p06 tp816a-2yfl2y-stiii-bd-120p06 tp816a-2yfl2y-stiii-bd-150p06 tp816a-2yfl2y-stiii-bd-200p06 tp816a-2yfl2y-stiii-bd-250p06 tp816a-2yfl2y-stiii-bd-300p06 tp816a-2yfl2y-stiii-bd-350p06 tp816a-2yfl2y-stiii-bd-400p06 tp816a-2yfl2y-stiii-bd-50
|
caledonian www.caledonian-cables.co.uk outdoor telephone cables www.addison-cables.com solid pe insulated lap sheathed air core cables to icea s-85625 application the cables are designed for use as subscriber distribution cables and as connection between central offices the cables are suitable for installation in ducts and aerial installation with integral suspension strand a figure-8 self support option is offered for aerial installation standards · icea s-85-625 formerly rus rea pe-22 rus rea pe-38 construction · conductors solid annealed bare copper 0.4/0.5/0.63/0.9mm as per astm b-3/class 1 of iec 60228 · insulation solid polyethylene as per astm d 1248/iec 60708 · twisted pairs insulated conductors are twisted into pairs with varying lay length to minimize crosstalk · cabling element twisted pairs · cable core assembly cables of 25 pairs or less are assembled into cylindrical core cables larger than 25 pairs are assembled into units which are then used to form the core units are
|
addison cabling element no 1 2 3 4 5 6 7 8 9 10 a-wire white white white white white red red red red red b-wire blue orange green brown grey blue orange green brown grey unit number 1 2 3 4 5 6 7 8 9 10 binder colour blue orange green brown grey white red black yellow violet cable size 2 pairs 5 pairs 10 pairs 20 pairs 50 pairs 100 pairs no and pair size of units in centre and 1st layer centre 1st layer 1x2 1x5 1 x 10 4x5 2 x 10 5 x 10 1 x 10 4 x 10 2 x 10 8 x 10 3 x 10 7 x 10 4x5 8 x 10 note the two pair cable is manufactured as a quad coloured orange green white and black in order of rotation dimensions and weight cellular pe insulated and lap sheathed jelly filled cable to cw 1128 cw 1128/1179 cable code number minimum sheath of thickness pairs mm maximum overall diameter mm unscreened nominal weight kg/km unscreened maximum overall diameter mm screened 9.0 10.0 11.5 15.5 20.0 9.0 9.5 11.0 13.5 18.0 23.5 10.0 12.5 14.5 17.5 25.5 33.5 nominal weight kg/km screened 60 85 130 260 470
|
addison continued from previous page number of pairs 30 50 70 100 150 200 10 20 30 50 70 100 150 200 10 20 30 50 70 100 150 200 10 20 30 50 70 100 150 support wire no x diameter mm 7x1.2 7x1.2 7x1.2 7x1.2 7x1.6 7x1.6 7x0.9 7x0.9 7x1.2 7x1.2 7x1.2 7x1.2 7x1.6 7x1.6 7x1.2 7x1.2 7x1.2 7x1.2 7x1.6 7x1.6 7x1.6 7x1.6 7x1.2 7x1.2 7x1.2 7x1.6 7x1.6 7x1.6 7x2.0 nominal inner outer sheath thickness mm 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.8 1.8/1.8 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.8 1.5/1.8 1.8/1.8 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.8 1.8/1.8 1.8/1.9 1.8/1.9 1.5/1.5 1.5/1.5 1.5/1.5 1.5/1.8 1.8/1.8 1.8/1.9 1.9/1.9 nominal cable dimensions height x diameter mm 24x14.8 26x17.0 28x18.6 30x21 35x25 28x28 21x12.7 23x14.3 25x15.8 27x18.2 29x21 33x24 37x27 41x30 23x13.9 25x16.0 27x17.8 30x21 35x24 39x28 43x32 47x36 25x16.1 18x19.1 31x22 37x27 41x31 46x35 53x41 nominal weight kg/km 389 489 575 695 975 1190 267 347 448 575 695 890 1220 1510 359 465 565 765 1030 1330 1770 2180 463 650 830
|
addison continued from previous page @150khz @772khz @1.6mhz @3.15mhz @6.3mhz minimum far-end cross-talk-worst pair power sum @150khz @772khz @1.6mhz @3.15mhz @6.3mhz minimum near-end cross-talk-mean power sum @150khz @772khz @1.6mhz @3.15mhz @6.3mhz minimum near-end cross-talk-worst pair power sum @150khz @772khz @1.6mhz @3.15mhz @6.3mhz nominal insulation thickness nominal insulated conductor diameter db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft mm mm 53 42 38 33 29 0.175 0.75 53 42 38 33 29 0.2 0.9 53 42 38 33 29 0.26 1.15 53 42 38 33 29 0.3 1.5 db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft 58 47 43 38 34 58 47 43 38 34 58 47 43 38 34 58 47 43 38 34 db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft 57 43 37 31 25 57 43 37 31 25 57 43 37 31 25 59 45 39 33 27 db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft db/305m db/kft 61 47 41 35 29 63 49 42 37 31 63 49 43 37 31 65 57
|
caledonian www.caledonian-cables.co.uk indoor telephone cables www.addison-cables.com indoor switchboard telephone cables to cw 1293 application the cables are designed to handle low frequency signals for short range applications suitable for cross connecting individual items of switchboard equipment and to connect exchanges with internal distribution points the cables are intended to be terminated in insulation/displacement connectors idc standards · cw 1293 · iec 60189-2 · iec 60332-1 · ul1581 vw-1 ul1666 · ieee 383ci.ie construction · conductors solid annealed bare copper 0.4/0.5/0.6/0.9mm as per class 1 of bs 6360 and iec 60228 · insulation colour coded pvc t154 to bs 7878 or equivalent lszh option can be offered upon request · twisted pairs insulated conductors are twisted into pairs with varying lay length to minimize crosstalk · cabling element twisted pairs/triples/quads · cable core assembly there are two modes of construction layer construction and unit construction for lay
|
caledonian www.caledonian-cables.co.uk indoor telephone cables www.addison-cables.com electrical properties nominal conductor diameter vde code conductor size maximum conductor resistance @20°c maximum loop resistance @20°c minimum insulation resistance @500v dc mutual capacitance @0.8khz 100 of all values max 95 of all values max capacitance unbalance @0.8khz k1 100 of values max 98 of values max k9-12 100 of values max 98 of values max maximum loop resistance @20°c impedance 4 -16 mhz maximum average attenuation @1mhz maximum average attenuation @4mhz maximum average attenuation @10mhz maximum average attenuation @16mhz maximum average attenuation @20mhz maximum working voltage peak value insulation material sheath material nominal insulation thickness nominal insulated conductor diameter mm mm pf/300m pf/300m pf/300m pf/300m pf/300m /km db/km db/km db/km db/km db/km v 800 400 300 100 130 100 15 35 55 73 86 95 225 pe pvc 0.25 1.1 800 400 300 100 130 100 15 35 55 73 86 95 225 pe lszh
|
addison xdsl connecting cables application the cables are designed for xdsl transmission system the cables are characterized by guaranteed data speeds up to 40mhz standards · er.f5.113 construction · conductors solid annealed bare copper sized 0.5mm as per astm b-3/iec 60228 class1 · insulation solid polyethylene as per astm d 1248/iec 60708 · twisted pairs insulated conductors are twisted into pairs with varying lays to minimize crosstalk · cable core assembly the pairs are cabled together in layers of 12 13 25 pair unit to form the cable core units are identified by colour coded binders · core wrapping one or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap · screen an aluminium polyster foil is applied longitudinally with an overlap · sheath black low density polyethylene as per bs 6234/iec 60708 · ripcord nylon ripcord may be placed parallel to the cores to facilitate sheath removal electrical properties conductor diameter maximum conductor
|
addison vde order code a-bcdefg hxi jklmn a basic types a outdoor telephone cables s switchboard cables j installation cables je fire alarm cables aj outdoor cable with protection against inductive influences t terminating cable b insulation types 02y cellular pe 2y solid pe 02ys foam skin insulating cover of cellular pe with additional skin of solid polyolefine y pvc h lszh c filling f petroleum jelly filling blank unfilled d screening material st static shield of plastic-backed aluminum tape for indoor cables d shield of copper wire whipping over one stranding element e.g pair lr corrugated alumnium tape blank no screen e bedding material 2y pe y pvc h lszh m lead sheath mz special alloyed lead sheath blank no bedding f armouring material b armouring sr corrugated steel tape t messenger of galvanized steel wires blank no armour g sheath material 2y pe y pvc h lszh l2y laminated sheath shield of pe coated aluminium tape bonded with pe sheath m lead she
|
|