Rigid Nonmetallic Conduit Switch Boxes
Type FSE
Single Gang FS Boxes
Part No.
Size
Vol. Cu. In.
Std. Ctn. Qty.
E980DFN
1/2
19
10
E980EFN
3/4
19
10
E980FFN
1
19
18
E980FFN-CAR
1
19
10
All sizes take standard covers
and accessories or devices.
Integral mounting feet
provide easy mounting.
For dead-end terminations.
Type FSC
All sizes take standard covers
and accessories or devices.
Detachable mounting feet
provide easy mounting.
For through terminations.
Part
Vol.
Std.
No.
Size
Cu. In. Ctn. Qty.
E981DFN
1/2
19
15
E981EFN
3/4
19
15
E981FFN
1
19
18
E981FFN-CAR
1
19
10
E42728
Type FSS
All sizes take standard covers
and accessories or devices.
Detachable mounting feet
provide easy mounting.
For multiple
dead-end circuit
terminations or
where additional
support is required
in stub-up
applications.
Type FSCC
All sizes take standard covers
and accessories or devices.
Det
|
w w w . c a r l o n . c o m
182
Rigid Nonmetallic Conduit Switch Boxes
Single Gang FD Deep Device Boxes
Type FD
All sizes take standard
covers and accessories or
devices. Integral mounting feet
provide easy mounting.
For terminations
where hub
requirements
vary according to
application hubs easily made
with flared wood
bit or hole saw.
Part
Vol.
Std.
No.
Size
Cu. In. Ctn.Qty.
E9801
N/A
25
10
For dead-end
terminations where
large devices or
additional wiring
capacity is required.
Type FDE
All sizes take standard covers
and accessories or devices.
Integral mounting feet
provide easy mounting.
Part
Vol.
Std.
No.
Size
Cu. In. Ctn. Qty.
E9801DN
1/2
25
10
E9801EN
3/4
25
10
E9801FN
1
25
10
Part
Vol.
Std.
No.
Size
Cu. In.
Ctn. Qty.
E9811DN
1/2
25
10
E9811EN
3/4
25
10
E9811FN
1
25
10
Type FDC
All sizes take standard covers
and accessories or devices.
Integral mounting feet
provide easy mounting.
F
|
w w w . c a r l o n . c o m
183
Rigid Nonmetallic Conduit Switch Boxes Covers
Two Gang FS Boxes
Type 2FSC
Part
Vol.
Std.
No.
Size
Cu. In. Ctn. Qty.
E9812D
1/2
32
10
E9812E
3/4
32
10
E9812F
1
32
10
All sizes take standard covers
and accessories or devices.
Integral mounting feet
provide easy mounting.
For through terminations
where two devices or
additional wiring capacity
is required.
Type FS
Part
Vol.
Std.
No.
Size
Cu. In.
Ctn. Qty.
E9802
N/A
32
10
All sizes take standard covers
and accessories or devices.
Integral mounting feet
provide easy mounting.
For terminations where hub
requirements vary according
to application hubs easily
made with flared wood bit
or hole saw.
Type 2FSE
Part
Vol.
Std.
No.
Size
Cu. In. Ctn. Qty.
E9802D
1/2
32
10
E9802E
3/4
32
10
E9802F
1
32
10
All sizes take standard covers
and accessories or devices.
Integral mounting feet
provide easy mounting.
For dead-end
ter
|
w w w . c a r l o n . c o m
188
Rigid Nonmetallic Conduit Technical Information
Corrosion Resistance of Carlon Schedule 40
and Schedule 80 PVC Conduit and Fittings
Carlon Schedule 40 and Schedule 80 are generally
acceptable for use in environments containing the chemicals
below. These environmental resistance ratings are based
upon tests where the specimens were placed in complete
submergence in the reagent listed. Schedule 40 and
Schedule 80 can be used in many process areas where
chemicals not on this list are manufactured or used because
worker safety requirements dictate that any air presence or
splashing be at a very low level.
If there are any questions for specific suitability in a
given environment, prototype samples should be
tested under actual conditions.
Acetic Acid O-20%
Acetic Acid 20-30%
Acetic Acid 3O-60%
Acetic Acid 80%
Acetic Acid Glacial
Acetic Acid Vapors
Acetylene
Adipic Acid
Alum
Aluminum Chloride
Aluminum Fluoride
Aluminum Hydroxide
|
w w w . c a r l o n . c o m
189
Rigid Nonmetallic Conduit Specification Format
A. The Carlon rigid nonmetallic conduit system shall be installed
as indicated on the drawings and as specified herein.
B. All wiring shall be installed in Carlon rigid nonmetallic conduit.
All conduit shall be secured by means of proper fittings. All
fittings shall be Carlon.
C. Carlon outlet boxes, fittings and junction boxes shall be used
for all outlets, pull boxes and junction points. (Lighting fixtures
shall not be supported or hung from PVC junction boxes but be
supported in position by other means.)
D. Exposed conduits shall be mounted securely by suitable
hangers or straps with the maximum spacing of points of
supports not greater than indicated by Section 352.30 of the
NEC.
E. Except where embedded in concrete or direct buried, Carlon
conduit shall be supported to permit adequate lineal
movement to allow for expansion and contraction of conduit
due to temperature change.
F.
|