uniclass l325:p4142 ci/sfb 31.9 epic f631:x442 hh2 march 2017 thermally broken lintel product selector march

contents 4 technically superior products 5  thermally broken lintel solution 6 thermal performance 8  structural performance 9 2 thermally broken

build it better with catnic catnic has pioneered the steel lintel for almost 50 years and designs manufactures and supplies the construction industry with technically superior products catnic was the first • lintel manufacturer to be listed on the bre certified thermal details and products scheme • lintel manufacturer to be certified to bes 6001 maximising the potential for obtaining credits under the responsible sourcing of materials sections of breeam the code for sustainable homes and ceequal • to develop the steel lintel in the uk and the first to gain both bba approval and the coveted kitemark to bs 5977 • to provide a built-in plaster key • was the first to ce mark its lintel product range far from just leading over the years catnic have worked with the bsi to establish the standards for lintels in this country and continue to develop and invest in improving on these standards with their extensive range of products and unique features •

technically superior products catnic is committed to innovation and constant improvement to meet the changes in building regulations leaders in technical innovation our rigid adherence to quality control compliance is your guarantee of technical superiority quality catnic are committed to quality control and is a bsi registered company with quality management systems in accordance with bs en iso 9001 2015 which provide a set of processes that ensure • clarification and documentation of policies and objectives • reduce waste relating to customers’ requirements to production with a view to achieving customer satisfaction • understanding how statutory and regulatory requirements impact on catnic and our customers • clear responsibilities and authorities increasing motivation and commitment • consistency and traceability of products and services • high level of internal and external communications material specification catnic’s standard

thermally broken lintel solution catnic’s latest innovation is the biggest evolution in steel lintel design for a generation an elegant simplistic design derived from extensive research and rigorous development testing offering a sophisticated practical solution to the latest changes in building regulations catnic’s patent pending tbl range is the most thermally efficient steel lintel solution on the market utilising the strength of steel combined with the thermal insulating properties of a high-density fire retardant core it’s design provides the thermal performance of separate lintels whilst offering users the same stable installations benefits of a traditional cavity wall lintel providing • industry leading linear thermal transmittance psi values of 0.02 to 0.05 w/mk • safe working loads in line with catnic’s existing cavity wall lintels • manufactured from powder coated galvanised steel • options are available to suit cavities

thermal performance the fabric energy efficiency standard fees forms the foundations of the building regulations part l 2013 this focuses on the thermal performance for walls roof and floors of the building which have been continually improved with the revisions to the regulations improving the thermal performance of the walls emphasises the increasing proportion of heat lost through thermal bridges in the building fabric such as lintels if these details are not improved the heat lost through linear thermal bridges in called the psi value and is measured in w/mk replacing the traditional lintels with a catnic thermally broken lintel the heat loss through the window head detail can be reduced by up to 96 sap 2012 appendix r part l of the building regulations has got progressively more complicated to make it easier to comply an optional “standard recipe” based on the part l 2013 notional dwelling has been introduced a summary is shown in the table opposite full details can

thermal performance gfed 30 c a b two-dimensional temperature distribution highlighting the effectiveness of the thermal break in the lintel 10mm airspace dabs [r 0.11 ∴ λ 0.01/0.11 0.09w/mk thickness mm λ value w/m.k 1.3 materials a window frame b plasterboard adhesive 12.5 10.0 0.19 0.09 c plasterboard on dabs air space 12.5 10.0 0.19 0.09 d blockwork 100 0.11 e insulation as required 0.022 f brick 103 0.077 g residual cavity 50 0.278 lintel steel 52 insulation 0.034 c  omment continuous band of adhesive to soffit area typical detail used for thermal modelling of the tbl range

structural performance the catnic thermally broken lintel range has been developed to provide the exact same safe working loads capacity of the standard catnic range of cavity wall lintels this allows a very simple conversion from the existing catnic cavity wall range to the tbl range without having to re-assess the loads over the lintels the range has been designed to cover all building types from small domestic dwellings up to and including large apartment blocks with concrete floors the composite design means the lintel is very stable during installation allowing it to be installed in the same way as a standard steel lintel with no propping required lintel design has been completed in line with en 845-2 structural testing was carried out by the university of south wales following en 846-9 the university of south wales is a notified testing laboratory for the testing of lintels as required by the construction products directive performance gap in recent years the housebuilding

ts th tx thermally broken lintels 90-105mm cavity 100-115mm inner leaf 90 125mm cavity wall 110-125mm cavity 100-115mm inner leaf all ratios are shown inner to outer standard duty standard duty standard lengths are available in 150mm increments up to 3000mm 300mm at lengths from 3000mm to 3600mm standard lengths are available in 150mm increments up to 3000mm 300mm at lengths from 3000mm to 3600mm ts90/100 ts110/100 7501500 16501800 19502100 22502400 25502700 28503600 15 18 20 22 26 26 weight kg/m 7.9 11.8 11.8 15.7 15.7 16.7 nominal height ‘h’ mm 153 202 202 233 233 229 standard lengths mm swl 1:1/3:1 kn 7501500 16501800 19502100 22502400 25502700 28503600 15 18 20 22 26 26 weight kg/m 8.0 11.9 11.9 15.8 15.8 16.9 nominal height ‘h’ mm 153 202 202 233 233 229 standard lengths mm swl 1:1/3:1 kn channel to inner leaf channel to inner leaf heavy duty heavy duty standard lengths are available in 150mm increments standard lengths are available in 150mm

ts th tx 130 165mm cavity wall thermally broken lintels 130-145mm cavity 100-115mm inner leaf 150-165mm cavity 100-115mm inner leaf all ratios are shown inner to outer all ratios are shown inner to outer standard duty standard duty standard lengths are available in 150mm increments up to 3000mm 300mm at lengths from 3000mm to 3600mm standard lengths are available in 150mm increments up to 3000mm 300mm at lengths from 3000mm to 3600mm ts130/100 ts150/100 7501500 16501800 19502100 22502400 25502700 28503600 15 18 20 22 26 26 weight kg/m 8.1 12.0 12.0 16.0 16.0 17.0 nominal height ‘h’ mm 153 202 202 233 233 229 standard lengths mm swl 1:1/3:1 kn 7501500 16501800 19502100 22502400 25502700 28503600 15 18 20 22 26 26 weight kg/m 8.2 12.2 12.2 16.1 16.1 17.1 nominal height ‘h’ mm 153 202 202 233 233 229 standard lengths mm swl 1:1/3:1 kn channel to inner leaf heavy duty heavy duty standard lengths are available in 150mm increments standard lengths are available

www.catnic.com care has been taken to ensure that the contents of this publication are accurate but tata steel europe limited and its subsidiaries which includes tata steel uk limited do not accept responsibility or liability for errors or information that is found to be misleading suggestions for or descriptions of the end use or application of products or methods of working are for information only and tata steel europe limited and its subsidiaries accept no liability in respect thereof before using products or services supplied or manufactured by tata steel europe limited and its subsidiaries customers should satisfy themselves as to their suitability catnic reserves the right to change information contained within this brochure at any time © copyright 2016 tata steel uk limited catnic pontypandy industrial estate caerphilly cf83 3gl t 029 2033 7900 f 029 2086 7796 www.catnic.com english version en 845-2 en 1090-1 bs en iso 9001 2015 fm 14913 bs en iso 14001 2015 ems 555046 bs