Catalog: Concrete Fasteners Catalog
Company/Brand: Concrete Fastening Systems
clean out in Concrete Fasteners Catalog by Concrete Fastening Systems
distance, at the end of which it tapers outwardly to the full diameter of the rod. A ... universal wedge clip on the stud. (2) Clean hole, place the ThunderStud wedge ... cutting which may not be able to be cleaned out of hole Anchor Spacing: The forces ...
consists of a threaded stud with an outwardly flared cone-shaped end. A tubular ... into the expander sleeve, wedging it outward and locking the anchor into the base ... same size bit as anchor diameter. (2) Clean hole with wire brush. (3) Make sure nut ... cuttings which may not be able to be cleaned out of hole. Anchor Spacing: The ... . HOLE SIZE HEAD STYLE MIN. EMBED PULL-OUT SHEAR Values shown are average ...
DRILL BIT THRD. LENGTH BOLT DIA. PULL-OUT Values shown are average ultimate ... , 12-77, matching the bit size with the outside diameter of the drop-in anchor being ... depth exceeds minimum embedment. (2) Clean out concrete dust from hole using a ... wire brush, compressed air or a blow out bulb. (3) Drive anchor into hole flush ...
. The top end of the anchor tapers outward from the anchor diameter into a tubular ... cone. The tapered diameter at the outer end of the anchor, in combination with ... one-quarter inch (1/4") or more. (2) Clean out hole of all dust and cuttings. (3) ... SIZE HOLE SIZE SCREW SIZE PULL-OUT 3000 PSI CONCRETE Values shown are ...
the length of the expansion shield. Clean out the hole of all dust and cuttings ... LENGTH HOLE SIZE BOLT DIA. PULL-OUT 6000 PSI CONCRETE Values shown are ...
the length of the expansion anchor. Clean out the hole of all dust and cuttings ... LENGTH HOLE SIZE BOLT DIA. PULL-OUT 5000 PSI CONCRETE Values shown are ...
for a portion of its length. The outside of the anchor has a series of ... plus one half inch (1/2") or more. (2) Clean the hole of all dust and cuttings. (3) ... SIZE HOLE SIZE ANCHOR LENGTH PULL-OUT 6000 PSI CONCRETE TECHNICAL DATA 1/4" ...
/4" deeper than expected embedment. (2) Clean out the hole of all dust and cuttings ...
" deeper than the anchor embedment. (2) Clean out hole of all dust and shavings. (3) ... DRILL BIT MINIMUM EMBEDMENT PULL-OUT Values shown are average ultimate ...
embedment or deeper, plus 1/4" (2) Clean dust out of hole. (3) Insert anchor ... SIZE MIN. EMB. DRILL BIT 3000 PSI PULL-OUT 3000 PSI SHEAR Values shown are ...
anchor has a single point that drills a clean hole and prevents paper damage. The ... strong engagement and resists stripping out. The tapered, oversized head seals the ... to 5/8" 25 lbs. 40 lb. 85 lb. PULL-OUT TEST IN WALLBOARD ...
Base Material (1) Drill 5/16" hole. (2) Clean out hole. (3) Fold anchor, insert ... spacing should be increased. SIZE PULL-OUT LBS. 1/4" PLYWOOD PULL-OUT LBS. 3/8" ... DRYWALL PULL-OUT LBS. 1/2" DRYWALL PULL-OUT LBS. 5/8" ...