Page 12 of Concrete Fasteners Catalog by Concrete Fastening Systems
10
p 888.498.5747
f 216.391.5352
www.confast.com
TAPCON CONCRETE
SCREWS
The TapCon brand concrete screw cuts
threads in a predrilled hole in concrete,
brick or block. The screw has alternating
raised and lowered threads with diamond cut notches which provide exceptional holding power and stability. The
TapCon brand concrete screw is available in both 3/16" or 1/4" diameters with
either a flat phillips #3 countersunk or a
5/16" hex washer head. All screws are
plated using the Stalgard coating which
provides extended life and additional
lubricity for ease of installation. TapCon
screws are also available in 410 stainless steel finished with a silver Stalgard.
The stainless steel screws have shown
no red rust in salt spray test performed
at a certified A2LA laboratory per ASTM
B117 specifications.
TECHNICAL INFO
Applications: Light to medium duty in concrete, brick and block.
Installation: (1) Drill hole into base material using the drill bit provided with the screws. The depth of the
hole must be at least 1/4" deeper than the TapCon embedment. (2) Place object to be fastened over
hole. (3) Insert point of Tapcon into hole and drive screw in using a nut drive or #3 bit tip. Do not over
torque the screw.
Screw Length: The length of the TapCon fastener to be used is determined by combining the thickness
of the material to be attached with the desired depth of embedment in the base material. It is recommended that a minimum of 1" and a maximum of 1-3/4" embedment be used in determining fastener
length. The diameter of the fastener and the depth of embedment affect pullout strengths. A carbidetipped drill bit is supplied with each box of TapCon fasteners. The correct hole must be drilled for the
screw to obtain holding values. In all cases the hole must be at least 1/4" deeper than the depth of the
fastener embedment.
SIZE
EMBEDMENT
CONCRETE 3725 PSI
HOLLOW BLOCK
All pullout values are based on close-tolerance holes drilled with Elco carbide tipped drill bits. Designated holding
power depends on the quality of the masonry material, depth of embedment, and proper hole size. These figures are
offered only as a guide and are not guaranteed by Elco Textron. The figures indicate average pullout and shear failure
values. A. safety factor of 4:1. or 25% of ultimate pullout value, is generally accepted as a safe working load, however,
reference should always be made to applicable codes for the specific safe working ration.
TECHNICAL DATA
PULL-OUT VALUES
3/16"
1"
380 lb.
229 lb.
3/16"
1-3/4"
1090 lb.
521 lb.
1/4"
1"
800 lb.
490 lb.
1/4"
1-3/4"
2100 lb.
801 lb.
SIZE
EMBEDMENT
CONCRETE 3725 PSI
HOLLOW BLOCK
SHEAR VALUES
3/16"
1-3/8"
875 lb.
690 lb.
1/4"
1-3/4"
1924 lb.
1059 lb.
[close]