Catalog: Concrete Fasteners Catalog
Company/Brand: Concrete Fastening Systems
pull out in Concrete Fasteners Catalog by Concrete Fastening Systems
consists of a threaded stud with an outwardly flared cone-shaped end. A tubular ... principle: Tightening of the nut pulls the coneshaped stud end into the ... expander sleeve, wedging it outward and locking the anchor into the base ... which may not be able to be cleaned out of hole. Anchor Spacing: The forces on ... DIA. HOLE SIZE HEAD STYLE MIN. EMBED PULL-OUT SHEAR Values shown are average ...
DRILL BIT THRD. LENGTH BOLT DIA. PULL-OUT Values shown are average ultimate ... , 12-77, matching the bit size with the outside diameter of the drop-in anchor being ... exceeds minimum embedment. (2) Clean out concrete dust from hole using a wire ... brush, compressed air or a blow out bulb. (3) Drive anchor into hole flush ...
ANCHOR SIZE ANCHOR LENGTH HOLE SIZE PULL-OUT 6000 PSI CONCRETE Values shown are ...
. The top end of the anchor tapers outward from the anchor diameter into a tubular ... cone. The tapered diameter at the outer end of the anchor, in combination with ... -quarter inch (1/4") or more. (2) Clean out hole of all dust and cuttings. (3) ... . ANCHOR SIZE HOLE SIZE SCREW SIZE PULL-OUT 3000 PSI CONCRETE Values shown are ...
length of the expansion shield. Clean out the hole of all dust and cuttings. (2) ... ANCHOR LENGTH HOLE SIZE BOLT DIA. PULL-OUT 6000 PSI CONCRETE Values shown are ...
length of the expansion anchor. Clean out the hole of all dust and cuttings. (2) ... ANCHOR LENGTH HOLE SIZE BOLT DIA. PULL-OUT 5000 PSI CONCRETE Values shown are ...
for a portion of its length. The outside of the anchor has a series of ... ANCHOR SIZE HOLE SIZE ANCHOR LENGTH PULL-OUT 6000 PSI CONCRETE TECHNICAL DATA 1/4" ...
and the depth of embedment affect pullout strengths. A carbidetipped drill bit is ... CONCRETE 3725 PSI HOLLOW BLOCK All pullout values are based on close-tolerance ... Textron. The figures indicate average pullout and shear failure values. A. safety ... factor of 4:1. or 25% of ultimate pullout value, is generally accepted as a safe ... safe working ration. TECHNICAL DATA PULL-OUT VALUES 3/16" 1" 380 lb. 229 lb. 3/ ...
than the anchor embedment. (2) Clean out hole of all dust and shavings. (3) ... . SIZE DRILL BIT MINIMUM EMBEDMENT PULL-OUT Values shown are average ultimate ...
or deeper, plus 1/4" (2) Clean dust out of hole. (3) Insert anchor through ... . SIZE MIN. EMB. DRILL BIT 3000 PSI PULL-OUT 3000 PSI SHEAR Values shown are ...
BIT SIZE SPACE BETWEEN EDGE DISTANCE PULL-OUT 2000 PSI SHEAR 2000 PSI Values shown ...
strong engagement and resists stripping out. The tapered, oversized head seals the ... 3/8" to 5/8" 25 lbs. 40 lb. 85 lb. PULL-OUT TEST IN WALLBOARD ...
through hole. (2) With one hand, pull ring so metal channel rests flush ... 3/8" to 2-1/2" N/A 2038 lb. 2392 lb. PULL-OUT VALUES 2 ...
(1) Drill 5/16" hole. (2) Clean out hole. (3) Fold anchor, insert anchor in ... the spacing should be increased. SIZE PULL-OUT LBS. 1/4" PLYWOOD PULL-OUT LBS. 3/8" ... DRYWALL PULL-OUT LBS. 1/2" DRYWALL PULL-OUT LBS. 5/8" DRYWALL Values shown are ...