Catalog: Cooper B-Line Spring Steel Fasteners
Company/Brand: Cooper Industries


 

Materials 8 Steel Specification High Carbon Cold Rolled ASTM A684, AISI 1055 ... Electrolytic Zinc Coated ASTM A591 Pre-Galvanized ASTM A653 Load Data The design load ... ratings for Cooper B-Line fasteners are specified in this catalog ... as static load capacity or ultimate static load capacity. By ... definition, the listed static load capacity has a safety factor of three (3.0), the ... listed ultimate static load capacity has no safety factor. In either case, ... these stated loads are not to be exceeded, and loads should be applied ... only as depicted in the catalog and/or instruction sheets. The load ... capacity of a fastener having more than one ... component is equal to the load capacity of the lowest rated component. ...


 

Technical Data Finishes Pre-Galvanized Zinc P re-galvanized steel is produced ... by coating coils of sheet steel with zinc by ... continuously rolling the material through molten ... or hot-dip mill galvanized. These coils are then slit to size and fabricated ... into Cooper B-Line pro d u c t s . The G90 specification calls for a ... coating of .90 ounces of zinc per square foot on each side of the sheet. ... During fabrication, cut edges and welded areas are not normally ... zinc coated; however, the zinc near the uncoated ... metal becomes a sacrificial anode to protect the bare areas after a short period of ... time. P re-galvanized steel is recommended for ...


 

/installation instruction sheets in packages before use. These products are designed ... for positioning only. No load rating. 17 Double Side ... Box Support Designed for pre f a b . Can be installed on either side of stud ... without re p o s i t i o n i n g box or devices. Adjustable far- s i d e s ... u p p o rts designed to reduce labor. Av a i ... l a b l e in three standard sizes. Double ... far-side supports prevent box movement in wall cavity. Finish: Pre- ... Galvanized BB73 BB74 BB76 782051 38645 BB73 3 1/2 , 2 1/2 50 782051 38717 BB74 4 ... , 3 1/2 , 2 1/2 50 782051 38759 BB76 6 50 Patent Pending UPC/Part Number ...


 

Wall Studs Cover Plate Mounting Bracket P rovides attachment base for low ... o u t l e t s . Replaces electrical box in Class 2 low voltage i n s t a l l a ... t i o n s . Can be piggy-backed. For 1/2 and 5/8 d rywall applications ... . Finish: Pre g a l v a n i z e d 781011 19873 BB15 ... Single Gang 50 Stud Bracket UPC/Part Number Description Catalog Number Box ... /installation instruction sheets in packages before use. These products are designed ... for positioning only. No load rating. 19 Switch Box ... Bracket Supports all 2" x 3" switch boxes with 1 or 2 screw plaster ears. ... for 2 1/2" 3 1/2" metal studs. Brackets may be piggy-backed in series on same ...


 

Wall Studs Box Mounting Bracket See BB216T Series for a better solution. S u p p ... o rts boxes located between studs 16" or 24" on center. Adjustable ... , fits both 1 1/2" and 2 1/8" deep b o x e s . Boxes attach easily with ... sheet metal s c rews thro u g h p re-punched holes. Bar is marked in 1/2" i n c re ... m e n t s . Finish: Pre g a l v a n i z e d 781011 18160 BB2-16 ... 16 1 1/2 50 781011 18165 BB2-24 24 1 1/2 50 781011 18161 BB2-16D* 16 ... 2 1/8 50 781011 18166 BB2-24D* 24 2 1/8 50 * Pre-formed brackets for ... 2 1/8" deep boxes Patent #5209444 #4967990 UPC/Part Number Stud ... Spacing Catalog Number Box Qty. 781011 01145 BB2-AC Bracket ...


 

Wall Studs Conduit/Cable Supports Allows conduit, MC, AC, or ... BX to be pulled through metal studs. Provides support for horizontal runs of conduit ... or cable through metal stud. Prevents conduit/cable rattling. Finish: Pre- ... galvanized 781011 01657 BX82 Up to 1 100 UPC/Part Number Conduit/ ... Cable Size Catalog Number Box Qty. 30 Read safety/installation ... instruction sheets in packages before use. These products are designed for ... positioning only. No load rating. Cable Fasteners Attaches Type NM cables to ... wood studs. Can be used to s u p p o rt computer, C AT V, telephone, ...


 

S u p p o rts 3/8" to 2" c o n d u i t . Unique G u i d e R i t e ... Fastener provides for fast and easy installation with ... pliers. Available with clearance hole for 1/4" bolt or 1/4" -20 thre a d ... i m p re s s i o n . Static Load Capacity: 100 Lbs. Ve rt i c a l 25 Lbs. ... Horizontal Conduit Cable Guide-Rite Conduit Fasteners Read safety/installation ... instruction sheets in packages before use. 35 781011 18350 BG-6* 3/8 100 ... 781011 18355 BG-8-12 1/2 , 3/4 100 781011 18360 BG-16 1 ... 100 781011 18365 BG-20 1 1/4 100 781011 18370 BG-24 1 1/2 ... 100 781011 18375 BG-32 2 100 Patent #4958792 781011 18380 BG-6-4T* 3/8 ... 100 781011 18385 BG-8-12-4T 1/2 , 3/4 100 781011 18390 BG-16-4T 1 ...


 

Conduit Cable Push-Type Conduit Fasteners Conduit easily snaps into ... push type fastener for s e c u re support . Available with ... clearance hole for 1/4" bolt or 1/4"-20 thre a d i m p re s s i o n ... . Ultimate Static L o a d C a p a c i t y : 25 Lbs. Ve rt i c a l 15 Lbs. ... /installation instruction sheets in packages before use. 15 Lbs. 25 Lbs. Ultimate ... Static Load Capacity Clearance Hole For 1/4" Bolt 781011 19200 BP-8 1 ... /2 EMT 100 781011 19205 BP-12 3/4 EMT 100 1/2 IMC, Rigid 781011 ... 19210 BP-16 1 EMT 100 3/4 IMC, Rigid 1/4"-20 ... Thread Impression 781011 19215 BP-8-4T 1/2 EMT 100 781011 19220 BP-12-4T 3/4 ...


 

For use with 3/8" to 2" conduit. G u i d e R i t e Fastener provides ... for fast and easy installation with pliers. Note: Total load of trapeze must not ... exceed 100 Lbs. Conduit Cable Guide-Rite Conduit Trapeze Fasteners ... /installation instruction sheets in packages before use. 37 781011 18615 BG-16-G-6 ... 3/8 100 781011 18620 BG-16-G-8-12 1/2 or 3/4 100 781011 18595 BG-16-G- ... 16 1 100 781011 18600 BG-16-G-20 1 1/4 50 781011 18605 BG-16-G-24 1 1/2 ... 50 781011 18610 BG-16-G-32 2 50 Patent #4958792 UPC/Part Number Conduit To 1 ... Trapeze Catalog Number Box Qty. An ideal spacer between conduits ... tools required. Ultimate Static Load Capacity: 25 Lbs. Push-Type Conduit To Conduit ...


 

Conduit Cable Rod Wire Fasteners BW2 and BW6 support #10-24 or 1/4 -20 ... threaded bridle rings and provide attachment for electrical boxes. BW4 ... supports cables from #12 thru #8 wire. 44 Read safety/ ... installation instruction sheets in packages before use. 25 Lbs. 50 Lbs. Static Load ... Capacity 781011 19705 BW4 Multi-size 100 Wire Fastener UPC/Part ... Number D e s c r i p t i o n Catalog Number Box Qty. MC/AC #12 #10 #8 #9 ... Cable Size Wire Wire Wire 14-2 Cable BW4 BW4 BW4 14-3 Cable BW4 BW4 BW4 12-2 ... Cable BW4 BW4 BW4 12-3 Cable BW4 BW-8 BW-8 BW4 is designed for positioning only. ...


 

781011 01402 BX-8 .375 to .706 O.D. 100 781011 02943 BX- ... 18 .706 to 1.380 O.D. 100 781011 01685 BX-8B Bulk Packed in 4000 Fiber Barrels UPC/ ... Part Number Cable/Conduit S i z e Catalog Number Box Qty. Conduit Cable Can be ... used in place of batwings. Will not bend or deform hanger wire. Attaches to #12 ... #8 wire and 1/4" plain rod. Accommodates MC, AC, 3/8" BX or ... 1/2" EMT. Cable can be installed before or after attachment to wire. Static ... Load Capacity: BX-8 20 Lbs. BX-18 30 Lbs. 48 Read safety/installation ... instruction sheets in packages before use. 781011 01219 BX4-W2 Single Runs ...


 

782051 04934 BX2 Usable Area = 100 2 sq. in. 781011 ... 19765 BX6 Usable Area = 100 4 sq. in. 781011 ... 19766 BX24 Usable Area = 100 13 sq. in. UPC/Part ... Number D e s c r i p t i o n Catalog Number Box Qty. Conduit Cable Flexible ... Cable S u p p o rt Designed to support multiple runs ... of MC, AC, BX or communication cable. Static Load Capacity: BX2 50 lbs. BX6 ... BX24 75 Lbs. Finish: Zinc Plated 50 Read safety/installation instruction ... sheets in packages before use. 781011 19770 BX9 Flexible Conduit ... 100 Fastener UPC/Part Number D e s c r i p t i o n Catalog Number Box Qty. ...


 

Secures conduit and electrical boxes to most structures. Provides support ... for conduit on either side of electrical box. ... Static load capacity: 25 lbs. Conduit Cable Guide-Rite Conduit Box Support ... /installation instruction sheets in packages before use. 53 781011 03575 BG-6-S18 3 ... /8 25 781011 03573 BG-8-12-S18 1/2 , 3/4 25 781011 03574 BG-16-S18 1 ... 25 781011 04979 BG-8-12-S18-S 1/2 , 3/4 25 Patent #4958792 UPC/Part ... Number Conduit Size EMT Rigid Catalog Number Box Qty. S18-S With 1/4 -20 x 5 ... /8 stud S18 Secures conduit and electrical boxes to most structures ... . Provides support for conduit on either side of electrical box. ...


 

Provides support for conduit on either side of electrical box. W2 ... series attaches to #12 wire thru 1/4 plain or threaded rod. W6 series attaches to ... 3/8 plain or threaded rod. Conduit Cable Push-Type Conduit Box Support Fasteners ... /installation instruction sheets in packages before use. 55 782051 23615 B P 8 S 1 8 ... W 2 1/2 EMT 2 5 782051 23619 B P 1 2 S 1 8 W 2 3/4 EMT, 1/2 IMC, Rigid ... 2 5 782051 23627 B P 1 6 S 1 8 W 2 1 EMT, 3/4 IMC, Rigid 2 5 ... 782051 23628 B P 8 S 1 8 W 6 1/2 EMT 2 5 782051 23629 B ... P 1 2 S 1 8 W 6 3/4 EMT, 1/2 IMC, Rigid ... 2 5 782051 23630 B P 1 6 S 1 8 W 6 1 EMT, 3/4 IMC, Rigid 2 5 ... UPC/Part Number Conduit Size Catalog Number Box Qty. 25 Lbs. Static Load ...


 

781011 18120 BA5-4T With 1/4 -20 100 Thread Impression ... 781011 03548 BRC3-A5 Supports Romex 100 Sizes #14-2 w/g and ... #12-2 w/g to T-Bar Romex is a trademark used by General ... Cable Corp. UPC/Part Number D e s c r i p t i o n Catalog Number Box Qty. ... Acoustical Tee Side Mount T-Bar Fasteners A positive method for ... supporting vertical boxes, conduit or cable above T-Bar. Allows conduit to clear ... /installation instruction sheets in packages before use. These products are designed ... for positioning only. No load rating. BA5-4T 781011 18410 BG-6-A5 3/8 100 781011 ... 18465 BG-8-12-A5 1/2 , 3/4 100 781011 18545 BG-16-A5 1 ...


 

781011 01220 BX4-A6 Single Runs 100 781011 01216 BX4M-A6 ... Note: Fasteners will rotate 360 . UPC/Part Number D e s c r i p t i o n Catalog ... Number Box Qty. 781011 01187 BX4-A5 Single Runs 100 781011 01212 BX4M-A5 ... Note: Fasteners will rotate 360 . UPC/Part Number D e s c r i p t i o n Catalog ... Number Box Qty. Acoustical Tee Top Mount T-Bar ... Fasteners A positive method for supporting cable or flexible ... conduit above T-Bar. Assemblies support MC, AC, sizes #14-2 ... through #10-3 or 3/8" BX. 60 Read safety/installation instruction ... sheets in packages before use. These products are designed for positioning only. No ...


 

781011 18080 BA12 Box Hanger 50 24 Span 781011 18082 BA12-12 ... Box Hanger 50 12 Span 781011 18085 BA12-20 Box Hanger 50 20 Span 781011 18087 BA12 ... -30 Box Hanger 50 30 Span UPC/Part Number D e s c r i p t i o n Catalog ... Number Box Qty. Acoustical Tee Electrical Box T- ... Bar Fasteners See BA50 for a better s o l u t i o n . S u p p o rts ... octagonal or square boxes. Allows for flush mounting or 3/4" off ... s e t for plaster ring. One BB27 box mounting clip with screw included with ... . For additional support , attach dro p w i re to BB27 Box Mounting Clip. Wa ... /installation instruction sheets in packages before use. 781011 18170 BB27 Box ...


 

782051 18460 BA50A Adjustable Box 10 Hanger for T-Bar UPC/Part Number D e ... s c r i p t i o n Catalog Number Box Qty. Acoustical Tee Adjustable Box S u ... p p o rt Heavy-duty adjustable box support for suspended ceilings. ... adjustments without measuring. Self-centering feature on bar positions box on center ... . Ideal for installation of speaker cases, emergency light fixture s , etc. in ... suspended ceilings. Static Load Capacity: 25 Lbs. without dedicated dro p w i re ... 70 Lbs. with dedicated dro p w i re 35 Lbs. (Canada) with dedicated ... d ro p w i re 64 Read safety/installation ...


 

782051 99873 BA40 Fixture Bar 20 pair UPC/Part Number D e s c r i p t i o n ... Catalog Number Box Qty. Acoustical Tee QuikFix Fastening ... grade downlights 50% faster than wire bound installation methods. QuikFix System ... is p re-sized for 24" spacing. No tools re ... /installation instruction sheets in packages before use. Patent 6286265 Innovative ... design features off s e t bar hangers with integral locking tabs that ... secure downlights to T-Bar and prevent lifting or sliding. C US UL ...


 

Acoustical Tee Light Fixture T-Bar Fasteners Read safety/installation ... instruction sheets in packages before use. 67 781011 18100 BA17 C A P R I 1 R ... -9X, R-10C 10 (Wide Bar) C A P R 1 R 1 0 X sets C A P R 1 P R 7 5 1 C ... X H A L O 2 H7, HALO 2 H17 J U N O 3 A P, APT J U N O 3 IC, ICT, J, SC, TC T H O ... M A S 4 R I I C 781011 18105 BA18 C A P R I 1 H S G 10 (Narrow Bar) L I G H T O ... L I E R 5 7 1 1 sets UPC/Part Number High Hat Fixtures Catalog ... Number Box Qty. UPC/Part Number High Hat Fixtures Catalog ... Number Box Qty. BA17 1/4" 5/8" BA18 1/8" 1/2" Adjustable span from 20" ...


 

781011 18020 BA-4-16 Black 5/8 100 781011 18055 BA-4-16-W White ... 5/8 100 781011 18025 BA-4-16-24 White 1 1/2 100 781011 18030 BA-4-16- ... 32 White 2 100 781011 18035 BA-4-16-48 White 3 100 781011 18060 BA-4-WN Black ... 100 UPC/Part Number S t u d L e n g t h Catalog ... Number Finish Box Qty. Acoustical Tee 15/16 Twist ... electrical fixtures from 15/16" T-Bar. 1/4"-20 stud available in varying ... lengths. Includes BA-4-WN wing nut with impression. Static Load ... Capacity: BA4-16 Series 50 lbs. BA4-WN Series 100 lbs. 70 Read safety/ ... installation instruction sheets in packages before use. BA-4-WN 781011 95575 BA-21 ... 1/4 Spacer 100 781011 99567 BA-21D 3/8 Spacer 100 UPC/Part Number D e s c ...


 

Secures conduit and electrical boxes to beam flanges 1/8 to 3/4 thick. Provides ... support for conduit on either side of electrical box. ... Static Load Capacity: 25 Lbs. Beams Guide-Rite Conduit Box Support ... /installation instruction sheets in packages before use. 91 781011 03583 B G 6 S 1 8 ... U 2 4 3/8 1/8 to 1/4 2 5 781011 03584 B G 6 S 1 8 U 5 8 3/8 5/1 6 to 1/2 2 5 ... 781011 03579 B G 8 1 2 S 1 8 U 2 4 1/2 , 3/4 1/8 to 1 ... /4 2 5 781011 03580 B G 8 1 2 S 1 8 U 5 8 1/2 , 3/4 5/1 6 to ... 1/2 2 5 781011 03581 B G 1 6 S 1 8 U 2 4 1 1/8 to 1/4 2 5 ... 781011 03582 B G 1 6 S 1 8 U 5 8 1 5/1 6 to 1/2 2 5 ... Patent #4958792 UPC/Part Number F l a n g e T h i c k n e s s ...


 

Hangers Suspend wire or plain and threaded rod from beam flanges 1/8 ... installed with a hammer. Static Load Capacity: 160 Lbs. 94 Read safety/installation ... instruction sheets in packages before use. 781011 18900 B H 1 E 2 4 1/8 1/4 ... #8 Wi re or 1 0 0 1/4 Plain Rod 781011 18905 B H 1 E 5 8 5/1 6 1/2 ... #8 Wi re or 1 0 0 1/4 Plain Rod 781011 18910 B H 1 E 9 1 2 9/1 6 3 ... /4 #8 Wi re or 1 0 0 1/4 Plain Rod UPC/Part Number D e s c r i p t i o ... n Catalog Number Flange Thickness Box Qty. 781011 18940 B H 2 E 2 4 1/8 1/4 ... 3/8 1 0 0 781011 18945 B H 2 E 5 8 5/1 6 1/2 3/8 1 0 0 781011 ... 18950 B H 2 E 9 1 2 9/1 6 3/4 3/8 1 0 0 UPC/ ... Part Number Plain Rod S i z e Catalog Number Flange Thickness Box Qty. Rod To ...


 

Hangers Compensates for angle of purlin lip. Allows for parallel conduit runs ... fasteners will rotate 360 . Maximum Purlin thickness of 3/32". 96 Read safety/ ... installation instruction sheets in packages before use. 781011 18345 B F 1 3 With 1 ... /4 Hole 100 100 781011 18340 B F 1 2 For S Hooks 100 100 UPC/Part ... Number S t a t i c Load Cap. L b s . Catalog Number Description Box Qty. Z Purlin ... Hangers 781011 18445 B G 6 F 1 3 3/8 1 0 0 1 0 0 781011 ... 18520 B G 8 1 2 F 1 3 1/2 , 3/4 1 0 0 1 0 0 ... 781011 18590 B G 1 6 F 1 3 1 1 0 0 1 0 0 781011 18675 ... B G 2 0 F 1 3 1 1/4 1 0 0 5 0 781011 ... 19290 B P 8 F 1 3 1/2 EMT 2 5 1 0 0 781011 19390 ... B P 1 2 F 1 3 3/4 EMT 2 5 1 0 0 1/2 IMC, ...


 

Hangers Suspend wire, or plain or threaded rod from vertical flanges ... 1/16" to 1/4" thick. Static Load Capacity: 160 Lbs. 102 Read safety/installation ... instruction sheets in packages before use. 781011 18310 B F 1 1/1 6 5/3 2 ... For S Hooks, 1 0 0 Bolting Straps and Wrap Wi re 781011 18315 B F ... 2 5/3 2 1/4 For S Hooks, 1 0 0 Bolting Straps and Wrap Wi re UPC/Part Number D ... e s c r i p t i o n Catalog Number Flange Thickness Box Qty. ... Vertical Flange Hangers 781011 18915 B H 1 F 1 1/1 6 5/3 2 #8 Wi re or 1 0 0 ... 1/4 Plain Rod 781011 18925 B H 1 F 2 5/3 2 1/4 #8 Wi re or 1 0 0 ... 1/4 Plain Rod UPC/Part Number D e s c r i p t i o n Catalog Number Flange ...


 

/installation instruction sheets in packages before use. 103 781011 18955 BH2-F1 1/ ... 16 to 5/32 3/8 100 781011 18965 BH2-F2 5/32 to 1/4 3/8 100 UPC/Part Number P ... l a i n Rod Size Catalog Number F l a n g e T h i c k n e s s ... Box Qty. 781011 18995 BH4-F1 1/16 to 5/32 1/4 100 781011 19075 BH6 ... -F1 1/16 to 5/32 3/8 100 781011 19005 BH4-F2 5/32 to 1/4 1/4 100 781011 19085 BH6- ... F2 5/32 to 1/4 3/8 100 UPC/Part Number T h re a d e d Rod Size Catalog ... Number F l a n g e T h i c k n e s s Box Qty. 781011 19035 BH5-F1* 1/16 to 5/32 ... 1/4 , 3/8 100 781011 19045 BH5-F2* 5/32 to 1/4 1/4 , 3/8 100 * Nuts ... required. UPC/Part Number P l a i n Rod Size Catalog Number F l a n ...


 

Replaces electrical box in Class 2 low voltage installations. Provides ... attachment base for low voltage outlets. Maximum 1 1/4 ... drywall thickness. Finish: Pre-galvanized Communication Low Vo l t a g e Cover ... Plate Mounting Bracket Read safety/installation instruction ... sheets in packages before use. These products are designed for positioning only. No ... load rating. 119 781011 90895 BB10L Single Gang 50 Bracket 781011 90896 ... BB20L Double Gang 50 Bracket UPC/Part Number Description Catalog Number Box ... Qty. P rovides attachment base for low voltage o u t l e t s . ... Replaces electrical box in Class 2 low voltage i n s t a l l a t i o n s ...


 

X y l a n c o a t i n g p rovides smooth frictionless surface for ... cable pulling. G reat for use in corn e r s , d rop-outs or dire c t i o n c ... h a n g e. X-Hook has lower c o e fficient of friction than Te f l o ... n . Qwik-Latch cable retainer included with each hook. ... Static Load Capacity: 30 Lbs. Communication Low Vo l t a g e Low Friction Cable ... /installation instruction sheets in packages before use. 123 782051 29940 B C H 2 1 ... X 1 5/16 50 4-Pair UTP 50 782051 29941 B C H 3 2 X 2 80 4-Pair UTP 50 782051 ... 29942 B C H 6 4 X 4 300 4-Pair UTP 25 UPC/Part Number Capacity Hook ...


 

S u p p o rts cable fro m #12 wire thru 3/8 t h readed ro ... d. Qwik-Latch cable retainer included with each hook. W2 ... series attaches to #12 wire thru 1/4 plain or threaded ro d. W6 series attaches ... to 3/8 plain or threaded ro d . Static Load ... Capacity: 25 Lbs. Finish: Pre-galvanized Communication Low Vo l t a g e Cable To ... /installation instruction sheets in packages before use. 127 782051 28081 BCH12-W2 ... 3/4 50 781011 04819 BCH21-W2 1 5/16 50 781011 04841 BCH32-W2 2 50 ... 782051 28082 BCH12-W6 3/4 50 781011 95567 BCH21-W6 1 5/16 ... 50 781011 95569 BCH32-W6 2 50 UPC/Part Number Description Catalog Number Box ... Qty. S u p p o rts cable above ceiling grid and allows 360 ro t a t i o n. P ...


 

Communication Low Vo l t a g e 128 Read safety/ ... installation instruction sheets in packages before use. Supports cable from ... computer floor post. Organizes cable off the floor for a neat installation ... . Qwik-Latch cable retainer included with each hook. ... Static Load Capacity: 30 Lbs. Finish: Pre-galvanized Cable To Floor S u p p o rt F a s t e n ... e r s 782051 28085 B C H 1 2 L 1 4 1 0 3/4 1 O.D. 50 781011 ... 04851 B C H 2 1 L 1 4 1 0 1 5/16 1 O.D. 50 ... 781011 04855 B C H 3 2 L 1 4 1 0 2 1 O.D. 50 781011 ... 04871 B C H 6 4 L 1 4 1 0 4 1 O.D. 25 UPC/Part ... Number Floor Post Size Hook Size Catalog Number Box Qty. Supports cable from ...


 

The industrys only fully adjustable pre-fab bracket. Completely adjustable fits a ... range of stud spacings and both 1 1/2 and 2 1/8 boxes. Box can be ... attached to slider bracket before installing on telescoping bracket. ... Factory assembly includes 4S box with solid ground wire and plaster ring ... . Ruff-In Pre-Fab Telescoping Slider Bracket Read safety/installation instruction ... sheets in packages before use. 141 782051 38614 B B 2 1 6 T S 2 5 ... 782051 38628 B B 2 2 4 T S 2 5 782051 38616 B B 2 1 6 T ... S 1 0 8 4 D 1 0 782051 38619 B B 2 1 6 T S 1 1 0 4 D 1 0 782051 38621 B ... B 2 1 6 T S 1 1 2 4 D 1 0 782051 38631 B B 2 2 4 T S 1 0 8 4 D 1 0 782051 38633 ...


 

Designed for pre f a b . Can be installed on either side of stud ... without re p o s i t i o n i n g box or devices. Adjustable far- s i d e s ... u p p o rts designed to reduce labor. Av a i ... l a b l e in three standard sizes. Double ... far-side supports prevent box movement in wall cavity. Pre-Fab unit ... includes box with solid ground wire and plaster ring. Finish: Pre-Galvanized Ruff-In ... Pre-Fab 146 Read safety/installation ... instruction sheets in packages before use. 782051 38645 B B 7 3 5 0 782051 ... 38717 B B 7 4 5 0 782051 38759 B B 7 6 5 0 U P C P a rt N u m b e r B o x ... Q t y. C a t a l o g N u m b e r BB 73 1 08 4D For Stud Size Device Style ...


 

Ruff-In Pre-Fab Pre-Assembled Double Side Box Support Read safety/ ... installation instruction sheets in packages before use. 147 782051 38648 B B 7 3 1 ... 0 8 4 D 1 0 782051 38649 B B 7 3 1 0 8 5 D 1 0 782051 38651 B B 7 3 ... 1 1 0 4 D 1 0 782051 38652 B B 7 3 1 1 0 5 D 1 0 782051 38658 B B 7 3 ... 1 1 2 4 D 1 0 782051 38661 B B 7 3 1 1 2 5 D 1 0 782051 38722 B B 7 4 ... 1 0 8 4 D 1 0 782051 38726 B B 7 4 1 0 8 5 D 1 0 782051 38733 B B 7 4 ... 1 1 0 4 D 1 0 782051 38736 B B 7 4 1 1 0 5 D 1 0 782051 38739 B B 7 4 ... 1 1 2 4 D 1 0 782051 38740 B B 7 4 1 1 2 5 D 1 0 782051 38764 B B 7 6 ... 1 0 8 4 D 1 0 782051 38765 B B 7 6 1 0 8 5 D 1 0 782051 38768 B B 7 6 ...


 

Built-in, adjustable far-side supports designed ... to reduce labor. Three different sizes pre-bent for 3 1/2 , 4 or 6 studs. No field ... bending required. Supports either 4S or 5S ... boxes. Brackets may be piggy-backed in series on same side of metal stud. ... Pre-Fab unit includes box with solid ground wire and plaster ring ... . Ruff-In Pre-Fab 148 Read safety/installation ... instruction sheets in packages before use. 781011 18190 B B 4 2 3 3 1/2 2 1/2 ... 1 0 0 No Plaster Ring or outlet box 781011 18200 B B 4 4 4 2 1/2 1 0 0 No ... Plaster Ring or outlet box 781011 18202 B B 4 6 6 1 0 0 No ... Plaster Ring or outlet box U P C P a rt N u m b e r B o x Q t y. C a t a l ...


 

Ruff-In Pre-Fab Pre-Assembled Single Sided Box Support Bracket Read ... /installation instruction sheets in packages before use. 149 782051 38812 B B 4 2 3 ... 1 0 8 4 D 1 0 782051 38814 B B 4 2 3 1 0 8 5 D 1 0 782051 38818 B B 4 ... 2 3 1 1 0 4 D 1 0 782051 38821 B B 4 2 3 1 1 0 5 D 1 0 782051 38824 B B 4 ... 2 3 1 1 2 4 D 1 0 782051 38826 B B 4 2 3 1 1 2 5 D 1 0 782051 38848 B B 4 ... 4 1 0 8 4 D 1 0 782051 38850 B B 4 4 1 0 8 5 D 1 0 782051 38853 B B 4 4 ... 1 1 0 4 D 1 0 782051 38854 B B 4 4 1 1 0 5 D 1 0 782051 38856 B B 4 4 ... 1 1 2 4 D 1 0 782051 38857 B B 4 4 1 1 2 5 D 1 0 782051 38879 B B 4 6 ... 1 0 8 4 D 1 0 782051 38881 B B 4 6 1 0 8 5 D 1 0 782051 38885 B B 4 6 ...


 

Uni-mount provides a secure box support and features a built-in plaster ... ring. Rigid bracket design eliminates the need for far-side ... support. Can be field assembled with 4S box or used for ... low-voltage applications. Pre-Fab Uni-mount includes 4S deep box and ... solid ground wire. Ruff-In Pre-Fab 150 Read safety/installation ... instruction sheets in packages before use. Uni-Mount Box Support 782051 ... 22768 B B 4 0 0 8 5 0 782051 22771 B B 4 0 1 0 5 0 782051 22772 B B 4 0 1 2 5 ... 0 782051 22773 B B 4 5 0 8 5 0 782051 22774 B B 4 5 1 0 5 ... 0 782051 22775 B B 4 5 1 2 5 0 782051 38597 B B 4 0 0 8 4 ...


 

Provides support for multiple boxes or plaster rings between studs 16 or 24 on center ... . Supports 4S or 5S boxes. Available factory assembled with ... plaster rings and/or boxes with solid ground wire to reduce labor ... . Custom factory assemblies are ordered by ... specifying plaster rings and/or boxes for each bracket position. Ruff-In Pre- ... Fab Multiple Box Mounting Bracket Read safety/installation instruction ... sheets in packages before use. 151 P o s i t i o n 1 P o s i t i o n 2 P o s ... i t i o n 3 P o s i t i o n 4 Plaster Rings One or Two Device with 1/2 , 5/8 ... or 3/4 raise Bracket Available for 16 24 stud spacing BB8- ...


 

Ruff-In Pre-Fab 152 Read safety/installation ... instruction sheets in packages before use. 782051 24855 BA50-OB-24 1 1/2 Deep ... Box 10 to T-Bar Fastener 782051 24856 BA50-OB-34 2 1/8 Deep Box 10 to T-Bar Fastener UPC ... /Part Number D e s c r i p t i o n Catalog Number Box Qty. Electrical Box T-Bar ... Fasteners Preassembled T-Bar fasteners speed installation. Boxes ... without independent support. 35 Lbs. in Canada 782051 24857 BA50-SB-24 1 1/2 Deep Box ... 10 to T-Bar Fastener UPC/Part Number D e s c r i p t i o n Catalog ... Number Box Qty. C US UL C US UL ...


 

Designed as a superior support for piping, cable tray, H VAC equipment, etc. UV ... resistant and a p p roved for most roofing material or ... other flat surf a c e s . Can be used with any of B L i n e s strut ... clamps and straps. Ultimate Load Capacity: 1,000 lbs. (uniform load) Rooftop ... 156 Designed as a superior support for piping, cable tray, HVAC equipment, etc. UV ... material or other flat surfaces. Can be used with any of B-Lines strut clamps ... and straps. Ultimate Load Capacity: (uniform load) C610 500 lbs. C620 1,000 ... lbs. C630 1,500 lbs. C640 2,000 lbs. C648 2,500 lbs. C6 Series Support Base With ...


 

NEC Requirements 170 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. Code Compliance for Spring Steel Fasteners Based on the ... 2005 NEC B-Line has recognized the need for a reference ... , detailing the National Electrical Code requirements for Spring Steel Fasteners ... . The following pages are reprinted portions of the 2005 NEC. These sections address ...


 

Requirements 171 90.4 Enforcement. This C o d e is intended to be suitable for ... mandatory application by governmental bodies that exercise legal jurisdiction over ... installations, including signaling and communications systems, and for use by insurance ... jurisdiction for enforcement of the C o d e has the responsibility for making ... materials, and for granting the special p e rmission contemplated in a number of ... the rules. By special permission, the authority having jurisdiction may ... waive specific re q u i rements in this C o d e or permit alternate methods where ... is assured that equivalent objectives can be achieved by establishing and ...


 

NEC Requirements 172 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. 300.4 Protection Against Physical Damage. W h e re subject to physical ... damage, conductors shall be adequately pro t e c t e d . (A) Cables and Raceways ... through Wood Members. ( 1 B o red Holes. . . . , holes shall be ... bored so that the edge of the hole is not ...


 

NEC Requirements 173 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire P rotection Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. (D) Cables and Raceways Parallel to Framing Members and Furring Strips ... . . . . , the cable or raceway shall be installed and supported so that the n e ... a rest outside surface of the cable or raceway is not less than 32 mm (1 1 ... where nails or scre w s a re likely to penetrate. W h e re this distance cannot be ...


 

NEC Requirements 174 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... and Supporting. (A) Secured in Place. Raceways, cable assemblies, boxes, ... cabinets, and fittings shall be securely fastened in place. Support ... wires that do not provide secure support shall not be permitted ... wires and associated fittings that provide secure support and that are installed ...


 

NEC Requirements 175 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire P rotection Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. Note: A previously acceptable practice, namely supporting ... cable and raceways by the ceiling grid, is no longer allowed. The intent ... means of secure support must be provided for cable assemblies, raceways, boxes, ... , which are installed specifically for cable support, must be secured at both ends ...


 

NEC Requirements 176 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. 3 1 0 . 1 5 Ampacities For Conductors Rated 0-2000 Volts. B )Tables ... Adjustment Factors. a M o re Than Three Curre n t C a rrying Conductors in a Raceway ... or Cable. Where the number of curre n t c a rrying conductors in a raceway ... or cable exceeds three, or where single ...


 

factors shall not apply to Type AC cable or to Type MC cable without an overall ... outer jacket under the following conditions: 1 Each cable has not more than thre e c ... u rre n t c a rrying conductors. ( 2 The conductors are 12 AWG copper ... . ( 3 Not more than 20 curre n t c a rry i n g conductors are bundled, ... stacked, or s u p p o rted on bridle rings . (See Figure 9) A 60 percent ... adjustment factor shall be applied w h e re curre n t c a rrying ... conductors in these cables that are stacked or bundled longer ... maintaining spacing exceeds 20. ( b M o re Than One Conduit, Tube, or ...


 

3 1 4 . 2 3 S u p p o rts. E n c l o s u res within the scope of this a ... rticle shall be supported in accordance with one or m o ... re of the provisions in 314.23 (A) through (H). (C) Mounting ... mounted in a finished surface shall be rigidly secure d t h e reto by clamps, ... . (See Figures 11 12) (D) Suspended Ceilings. An enclosure mounted to s t ructural or ... supporting elements of a suspended ceiling shall be not more than 1650 cm 3 (100 ... in. 3) in size and shall be securely fastened in place in a c c o ... 1) Framing Members. An enclosure shall be fastened to the framing members by ... mechanical means such as bolts, screws, or rivets, or by the use of ...


 

NEC Requirements 179 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire P rotection Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. (D) Boxes at Ceiling-Suspended (Paddle) Fan O u t l e t s . Outlet ... boxes or outlet box systems used as the sole support of a ... ceiling-suspended (paddle) fan shall be listed, shall be marked by their ... manufacturer as suitable for this purpose, and shall not support ceilingsuspended ...


 

NEC Requirements 180 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. Article 320 Armored Cable : Type AC 320.17 Through or Parallel to ... Framing Members. Type AC cable shall be protected in accordance with 300.4 (A ... ), (C), and (D) where installed through or ... parallel to framing members. (See Figures 17 18 ... Supporting. (A) General. Type AC shall be supported and secure d by staples, ...


 

NEC Requirements 181 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire P rotection Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. parallel to framing members. Grommets used as re ... q u i red in 300.4(B)(1) shall remain in place and be l i s ... t e d for the purpose of cable pro t e c t i o n . (See Figures 17 18) 3 3 4 . 3 ... and Support i n g . N o n m e t a l l i c sheathed cable shall be supported and ...


 

NEC Requirements 182 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. A rticle 344 Rigid Metal Conduit : Type RMC 3 4 4 . 3 0 Securing and ... n g . (A) Securely Fastened. RMC shall be securely fastened within 900 mm (3 ft ... ) of each outlet box, junction box, device box, cabinet, conduit body, or ... other conduit termination. Fastening shall be p e ...


 

NEC Requirements 183 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire P rotection Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. device box, cabinet, conduit body, or other tubing t e rmination. ( ... 1: Fastening of unbroken lengths shall be permitted to be increased to a distance ... structural members do not readily permit fastening within 900 mm (3 ft). ... Exception No. 2: For concealed work in finished buildings or ...


 

NEC Requirements 184 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... 410.16 Means of Support . (A) Outlet Boxes. Outlet boxes or fittings installed as ... re q u i red by 314.23 and complying with the provisions of 314.27(A) and ... 314.27(B) shall be permitted to s u p p o rt luminaries (fixture s . (C) ... Suspended Ceilings. Framing members of suspended ceiling ...


 

NEC Requirements 185 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire P rotection Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. F i g u re 27 BA15 F i g u re 28 BA1 F i g u re 29 BA40 F ... i g u re 30 BA 4-16 Series F i g u re 31 BAX Series F ... i g u re 32 BA50F ...


 

TIA/EIA Requirements 186 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire Pro t e c t i o n Association, on the re f e ... renced subject which is re p resented only by the standard in its ... N S I T I A E I A 5 6 9 A 4. Horizontal pathways and related spaces 4.6 Ceiling pathway ... 4.6.2 Design guidelines 4.6.2.1 Planning. The design shall provide a suitable ... means for supporting cable from the telecommunications closet to ... the work areas to be s e rved. Cable shall not be laid directly on the ...


 

TIA/EIA Requirements 187 Reprinted with permission from NFPA 70-2005, the National ... Electrical Code , Copyright 2005, National Fire Pro t e c t i o n ... . This reprinted material is not the complete and official position of the National ... Fire P rotection Association, on the re f e ... renced subject which is re p resented only by the standard in its ... entire t y. F i g u re 33 BCHxx-A28 F i g u re 34 BCHxx-W2 ...


 

Reference Data Cable Hook Technical Data 189 H o o k A B ... S p a c i n g C l e a r a n c e O v e r a l l O v e r a l l S i z e H ... .50 18.20 9.19 Double-Sided Double-Tier Cable Fasteners H o o k N o . A B S p a c ... i n g C l e a r a n c e O v e r a l l O v e r a l l S i z e ... 3.19 28.08 4.82 Single-Sided Multi-Tier Cable Fasteners (2 thru 6 Tier) A Clearance ... Overall Width .75 .75 .32 B Spacing Typ. Overall Height A B ... Overall Height Clearance Overall Width .75 .32 Spacing ...


 

N o m i n a l P i p e O u t s i d e Wa l l We i g h t We i ... g h t S i z e D i a m e t e r T h i c k n e s s of Pipe of Wa t e r I n . I n ... . I n . Lbs. Per Ft. Lbs. Per Ft. 1/8 0.405 0.068 0.04 0.02 1/4 0. ... .30 4 4.500 0.237 1.90 5.50 Schedule 40 PVC Plastic Pipe We i g h t N o m i n a l M ... i n i m u m of Conduit N o m i n a l O u t s i d e I n s i d e ... z e D i a m e t e r D i a m e t e r of Conduit C o n d u c t o r s I n . I n . I n . ... Lbs. Per 100 Ft. Lbs. Per 100 Ft. 1/2 0.840 0.560 11.0 33.1 3/4 ... Data 192 Dimensions taken from ANSI B1.1 1982 Unified Inch Screw Threads. All ... are UNCR series. Tabulated loads are based on an allowable tensile stress of 12000 ... psi reduced by 25% resulting in 9000 psi. From ANSI/MSS SP-58, Table 3. Note: All ...


 

Tr a d e G ro u n d i n g A rm o r A p p ro x i m a t e S i z e Conductor AW G O ... . D . Wt. Per 100 Ft. I n . L b s . 14-2 Solid 14 0.470 17.5 14-3 Solid ... .0 2-4 Stranded 6 1.295 164.0 MC Metal Clad Cable Specifications P a i r AW G C o u ... t S i z e O . D . We i g h t I n . Lbs. Per 100 Ft. 2 24 0.16 1.3 3 24 0.18 1.7 4 ... 0.27 3.5 8 24 0.30 4.2 25 24 0.50 13.0 Category 5 Cable Note: All dimensions and ... weights are subject to variation between manufacturers. Consult cable ...


 
  Similar searches   p c p b 260 3 c 2 0 b 3 (45)
r p c valve (152)
p 12 magazines (179)
p o cruises uk (15)
p o holiday cruise uk (11)
p o cruise ships (167)
p o european cruise ships (8)
ndl t p (17)
51 p 22 (430)
p t o control tower (12)
p 44 l (499)
p s 661 (106)
ruger p 944 (6)
p 205 (391)
p 325 (283)
p 308 (163)
parker fittings p series (7)
p trap (125)
p trap 1 (112)
j p u bearings (57)
p 133 (315)
ps1 p (7)
ford p 100 (205)
p 291 (164)
320 p (436)
kz 1000 p (9)
adapted p e srjc (10)
f26 p (18)
268 p 2 (112)
m 1505 p (11)
pws p (25)
p s pump (582)
65 p 14 (854)
p 647 (74)
p 210 (532)
filter p 1 (588)
c b radios (360)
268 p 06 04 (6)
p 337 (108)
volvo p (31)
lined p clip (166)
syncro 2 p (47)
j p cycle catalog (17)
p 264 (247)
p 350 clutch master cylinder (13)
p 321 (174)
cutter p (95)
p clip (603)
p injection pumps (147)
p pumps (898)
p 1410 (77)
401 p (330)
p 113 (450)
p 994 (39)
p 194 (191)
p 211 (331)
p clips (603)



Home | Latest catalogs | Contact

© 2006-2008 by who-sells-it.com