Catalog: West Brand Product Catalog
Company/Brand: Danaher Industrial Controls
|
| | on the controller. Universal Input: Accommodates Thermocouple , RTD, DCmV and mA Inputs ... Power Supply: Allows the controller to accept 95 265V AC 50 60Hz. Low Voltage ... Operation: Allows the controller to accept 20-50V AC or 22-65V DC Configuration ... -type port makes configuration fast, accurate and reliable. All configuration ... , manufactured by Danaher Industrial Controls! For over 50 years, we have steadily ...
|
| | in order to take the appropriate action in controlling the process. In ... to replace relays. They switch 120/240V AC and can handle up to a 1 amp load. ... to drive thyristors or other types of actuators. Other Control Outputs- Valve Motor ... or 2 Triac Outputs to drive valve actuators open or close. In addition, these ...
|
| | Output: Relay- SPST 2A at 120/240V AC SSR: 10V DC into 1 KOhm minimum Alarms ... outputs are available 2A 120/240V AC (or SSR 10V into 500 Ohm minimum) ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of input span 1 LSD ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ... Low Voltage Option: 12-30V DC, 12-24V AC 50/60 Hz EMI Immunity: Complies with BS ...
|
| | /Line Voltage 0 Green Display 90-264V AC 1 Red Display 90-264V AC 2 Green ... Display 24V AC/DC 3 Red Display 24V AC/DC ...
|
| | DC (mA) DC (mA) MAINS (LINE) SUPPLY 24V AC SUPPLY (Optional) 12-30V DC SUPPLY ( ...
|
| | include a retransmission output, a 24V AC/DC input power supply, plus a remote ...
|
| | Output: Relay- SPST 2A at 120/240V AC Alarms Option: 2 alarms standard 2 ... alarms 2A 120/240V AC Communications: RS-485 2 wire Option ... Operating and: Accuracy: 0.25% of span 1 LSD Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ... Low Voltage Option: 20-50V AC, 22-65V DC EMI Immunity: Complies with ...
|
| | better overall "quality control" with accurate "hands-free" tuning and faster, easier ... boards and covers the 94-264 Volts AC, 50/60 Hz range. It's sealed front panel ... provides for reliable and accurate operation in harsh environments ...
|
| | 47KW for V ranges and 5W for mA ranges Accuracy 0.1% of input range 1 LSD (T/C CJC ... ), control O/Ps turn off, high alarms activate for T/C and mV ranges, low alarms ... activate for RTD, mA or V ranges Outputs Options ... Contacts SPDT 2 Amp resistive at 240V AC, 500,000 operations Control SSR Driver ... minimum Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz DC Linear ... have 2% over/under drive applied. Accuracy 0.25% at 250W (degrades linearly to 0.5 ... 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts) Front Panel ...
|
| | Upper, RedLower POWER SUPPLY 0 100-240V AC 2 24-48V AC/DC OPTIONS 0 Not Fitted 1 ...
|
| | Outputs: 2 Relays- SPDT 2A at 120V AC (motor drive), 2A at 240V AC (resistive ... 80° C Alarm Output: 1 Relay- 2A at 240V AC or 1 SSR 4.2V DC Recorder Output: 0-5V ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of input span 1 LSD ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ... Low Voltage Option: 20-50V AC, 22-65V DC EMI Immunity: Meets with BS ...
|
| | Output: Relay- SPsT 2A at 120/240V AC for time proportioning operation. 5A at ... 120/240V AC for static operation. SSR: 10V DC into ... outputs are available 2A 120/240V AC (or SSR 10V into 500 Ohm minimum) ... to 9 minutes 59 seconds Operating and: Accuracy: 0.1% of input span 1 LSD Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ...
|
| | 2 Wire Serial Comms 02 Line voltage 24V AC/DC 12 RS-485 2 Wire Serial Comms and ... Line Voltage 24V AC/DC 30 Remote run/hold (digital input) ... (digital input) and Line Voltage 24V AC/DC NOTES: 1. The RTD 0.0 range will ...
|
| | Output: Relay- SPDT 2A at 120/240V AC for time proportioning operation. SSR: ... Option: 1 Alarm- 1 Relay 2A at 120/240V AC Communications: None Control and: ... to 9 minutes 59 seconds Operating and: Accuracy: 0.25% of span 1 LSD Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Optional 20-50V AC, 50/60Hz, 22 ...
|
| | 1 Relay Constant Line Supply 0 90-264V AC 2 24 V AC/DC NOTES: 1. The RTD 0.0 ...
|
| | Output: Relay- SPDT 2A at 120/240V AC SSR: 10V DC into 1 KOhm minimum Triac- ... plus Heater Break Alarm 2A 120/240V AC or SSR 10V into 500 Ohm minimum ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of span 1 LSD Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Optional 20-50V AC, 22-65V DC ...
|
| | : Limit Outputs: Relay- SPDT 5A at 240V AC Alarm Outputs: 2 Alarms as standard ... Relay- SPDT 2A at 120/240V AC Recorder Output: 0-5V and 0-10V ... Control: Manual Reset Operating and: Accuracy: 0.25% of span 1 LSD Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ... Low Voltage Option: 20-50V AC, 22-65V DC Dimensions and: Panel Cut-Out ...
|
| | output, a transmitter power supply, 24V AC/DC input power, remote reset, and RS485 ...
|
| | Output: Relay- SPDT 2A at 120/240V AC Alarms Option: 2 alarms if two physical ... outputs are available 2A 120/240V AC Communications: RS-485 2 wire-MODBUS ... - 9600, 4800, 2400, 1200 Operating and: Accuracy: 0.25% of input span 1 LSD ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz (Optional 20-50V AC 50/60 Hz, ...
|
| | INPUT Linear (mA) - - REMOTE RESET 24V AC SUPPLY 24V DC SUPPLY - 18 ...
|
| | 0 to 50mA 10 Volts DC 100mV 3 AC Volts/Amps 5 DC Volts/Amps 6 Strain ... -50 VAC/VDC Power Consumption: 4 Watts Access. Power Supply: 9-15 (unregulated VDC), ... Process: to 50 mA, 10Volts DC, 100 mV AC Volts/Amps: from 0-1 VAC to 0-600 VAC, ... mA to 0-2 amps Strain Gauge: 0-100 mVDC Accuracy: 0.1% of span 0.01% of span for DC ... Break: detected within 2 secs. (N/A to AC DC Volts/ Amps) Unique Model ...
|
| | 47KW for V ranges and 5W for mA ranges Accuracy 0.1% of input range 1 LSD (T/C CJC ... ), control O/Ps turn off, high alarms activate for T/C and mV ranges, low alarms ... activate for RTD, mA or V ranges Outputs Options ... Contacts SPDT 2 Amp resistive at 240V AC, 500,000 operations Control SSR Driver ... minimum Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz DC Linear ... have 2% over/under drive applied. Accuracy 0.25% at 250W (degrades linearly to 0.5 ... 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts) Front Panel ...
|
| | SUPPLY VOLTAGE 0 100-240 VAC 2 24-48 AC or DC DISPLAY COLOR 0 Red Upper Red ...
|
| | Outputs: 2 Relays- SPDT 2A at 240V AC 5 X 10 5 operations (resistive) 2 ... 80° C Alarm Output: 1 Relay- 2A at 240V AC or 1 SSR 4.2V DC Recorder Output: 0-5V ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of input span 1 LSD ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ... Low Voltage Option: 20-50V AC, 22-65V DC EMI Immunity: Meets with BS ...
|
| | Alarm Outputs: Relay- SPDT 2A at 240V AC 5 X 10 5 operations Control Outputs: ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of input span 1 LSD ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz (Optional 20-50V AC 50/60Hz, 22 ... High X 48mm Wide X 100mm Deep Results achieved against competitor PID and fuzzy logic ...
|
| | 32 Dual Setpoint Switching and 24V AC/DC Power Supply Second Analog Input ...
|
| | COMMS. B A COM N/C N/O C - + 24V 24V AC DC + - Remote Setpoint Input V/mA/mV ...
|
| | Output: Relay- SPDT 2A at 120/240V AC SSR: 10V DC into 1 KOhm minimum Triac- ... plus Heater Break Alarm 2A 120/240V AC or SSR 10V into 500 Ohm minimum ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of span 1 LSD Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Optional 20-50V AC, 22-65V DC ...
|
| | 47KW for V ranges and 5W for mA ranges Accuracy 0.1% of input range 1 LSD (T/C CJC ... ), control O/Ps turn off, high alarms activate for T/C and mV ranges, low alarms ... activate for RTD, mA or V ranges Outputs Options ... Contacts SPDT 2 Amp resistive at 240V AC, 500,000 operations Control SSR Driver ... minimum Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz DC Linear ... have 2% over/under drive applied. Accuracy 0.25% at 250W (degrades linearly to 0.5 ... 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts) Front Panel ...
|
| | SUPPLY VOLTAGE 0 100-240 VAC 2 24-48 AC or DC DISPLAY COLOR 0 Red Upper Red ...
|
| | Outputs: 2 Relays- SPDT 2A at 240V AC 5 X 10 5 operations (resistive) 2 ... 80° C Alarm Output: 1 Relay- 2A at 240V AC or 1 SSR 4.2V DC Recorder Output: 0-5V ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of input span 1 LSD ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ... Low Voltage Option: 20-50V AC, 22-65V DC EMI Immunity: Meets with BS ...
|
| | Alarm Outputs: Relay- SPDT 2A at 240V AC 5 X 10 5 operations Control Outputs: ... to 99 minutes 59 seconds Operating and: Accuracy: 0.25% of input span 1 LSD ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz (Optional 20-50V AC 50/60Hz, 22 ... ° C 50° C Disturbance PID RaPID Results achieved against competitor PID and fuzzy logic ...
|
| | 32 Dual Setpoint Switching and 24V AC/DC Power Supply Second Analog Input ...
|
| | COMMS. B A COM N/C N/O C - + 24V 24V AC DC + - Remote Setpoint Input V/mA/mV ...
|
| | Alarm Outputs: Relay- SPDT 2A at 240V AC 5 X 10 5 operations Control Outputs: ... Delay Start: 0 99:59 Operating and: Accuracy: 0.25% of input span Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz (Optional 20-50V AC 50/60Hz, 22 ...
|
| | COMMS. B A COM N/C N/O C - + 24V 24V AC DC N/O C N/C Notes: #1 R0 RESET RUN/ ...
|
| | : Limit Outputs: Relay- SPDT 5A at 240V AC Alarm Outputs: 2 Alarms as standard ... Relay- SPDT 2A at 120/240V AC Recorder Output: 0-5V and 0-10V ... Control: Manual Reset Operating and: Accuracy: 0.25% of span 1 LSD Environmental ... C (Storage) Supply Voltage: 90 to 264V AC 50/60Hz Power Consumption: 4W Maximum ... Low Voltage Option: 20-50V AC, 22-65V DC Dimensions and: Panel Cut-Out ...
|
| | RS485 SERIAL COMMS. B A COM - + 24V 24V AC DC Remote Reset Input N/C N/O C ...
|