Catalog: West Brand Product Catalog
Company/Brand: Danaher Industrial Controls
|
| | 6 West brand Control Basics: This section is intended to ... if you are uncertain which type of controller is most appropriate for your ... . INPUT TYPE An automatic process controller needs to measure the controlled ... order to take the appropriate action in controlling the process. In temperature ... of signal, i.e.: 4-20mA DC, 0-5V DC. CONTROL OUTPUTS Four Main Types Of Control ... or other types of actuators. Other Control Outputs- Valve Motor Drive: Valve Motor ... open or close. In addition, these controllers may incorporate a slidewire feedback ... positional information back to the controller. Dual Output: For some applications ...
|
| | 14 West brand 2300 1/32 DIN Controller/Indicator Largest red or green ... and a solid state driver for primary control and alarming. Specially developed ... Tune continuously monitors and improves control. The 2300 is a 1/32 DIN controller which ... has been designed to be our smallest control offering without sacrificing ... plus the simplified operation of the control. The controller is provided with hands ... push-buttons on the front of the control. Functionality has not been compromised ... a 5 amp relay and an SSR for primary control and alarming. An optional second alarm ...
|
| | West brand 6100+ Brief Specs: Features Control Types Full PID with Pre-tune, Self-tune ... , manual tuning, or On-Off control. Heat only or heat cool Auto/Manual ... Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply ... OR AND. Also 1 loop alarm for process control security. Process alarms have ... seconds (except zero based DC ranges), control O/Ps turn off, high alarms activate for ... for RTD, mA or V ranges Outputs Options Control Alarm Relays Contacts SPDT 2 Amp ... at 240V AC, 500,000 operations Control SSR Driver Outputs Drive capability 10V ... to 10V, 0 to 5V, 1 to 5V into 500W min. Control outputs have 2% over/under drive ... between 2 setpoints or Auto/Manual control. Volt free or TTL input Remote Setpoint ...
|
| | 38 West brand 6600 1/16 DIN Controller with Heater Break Alarm Heater Break ... available. The 6600 is a 1/16 DIN controller that has been designed specifically to ... provide quality process control for the Plastics Extrusion Market. This ... control features a special Heater Break Alarm ... configured for fast access to display amps or process temperature by a single key ... -up. Soft Start is included on this control, and is used to dry heaters out prior to ... cartridge heater applications. The 6600 controller incorporates our advanced tuning ... and normal operating conditions to control overshoot. The self-tune is a ... referred to as adaptive tuning. This control can also be manual fine tuned for ... specific applications. This controller loaded up can have 4 outputs, 1 sensor ... the West 6600 one of the most powerful controllers in its class. NEMA 4 ...
|
| | These intelligent units offer multiple control alarm outputs, optional serial ... models for Temperature, Process, Volts/Amps Front panel reset enable and preset ...
|
| | to 50mA 10 Volts DC 100mV 3 AC Volts/Amps 5 DC Volts/Amps 6 Strain Gauge Function ... : Control Inputs: Type: Sinking, Edge Sensitive ... : to 50 mA, 10Volts DC, 100 mV AC Volts/Amps: from 0-1 VAC to 0-600 VAC, 0-1 mA to 0- ... 1 amp DC Volts/Amps: from 0-100 mV to 0-600 VDC, 0-1 mA to 0 ... -2 amps Strain Gauge: 0-100 mVDC Accuracy: 0.1 ... within 2 secs. (N/A to AC DC Volts/ Amps) Unique Model Specifications Digital ...
|
| | + Brief Specs: Brief Specs: Features Control Types Full PID with Pre-tune, Self-tune ... , manual tuning, or On-Off control. Heat only or heat cool Auto/Manual ... Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply ... OR AND. Also 1 loop alarm for process control security. Process alarms have ... seconds (except zero based DC ranges), control O/Ps turn off, high alarms activate for ... for RTD, mA or V ranges Outputs Options Control Alarm Relays Contacts SPDT 2 Amp ... at 240V AC, 500,000 operations Control SSR Driver Outputs Drive capability 10V ... 10V, 2 to 10V, 0 to 5V into 500W min. Control outputs have 2% over/under drive ... between 2 setpoints or Auto/Manual control. Volt free or TTL input Remote Setpoint ...
|
| | 64 West brand 8600 1/8 DIN Controller with Heater Break Alarm Heater Break ... available. The 8600 is a 1/8 DIN controller that has been designed specifically to ... provide quality process control for the Plastics Extrusion Market. This ... control features a special Heater Break Alarm ... configured for fast access to display amps or process temperature by a single key ... -up. Soft Start is included on this control, and is used to dry heaters out prior to ... cartridge heater applications. The 8600 controller incorporates our advanced tuning ... and normal operating conditions to control overshoot. The self-tune is a ... referred to as adaptive tuning. This control can also be manual fine tuned for ... specific applications. This controller loaded up can have 4 outputs, 1 sensor ... the West 8600 one of the most powerful controllers in its class ...
|
| | + Brief Specs: Brief Specs: Features Control Types Full PID with Pre-tune, Self-tune ... , manual tuning, or On-Off control. Heat only or heat cool Auto/Manual ... Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply ... OR AND. Also 1 loop alarm for process control security. Process alarms have ... seconds (except zero based DC ranges), control O/Ps turn off, high alarms activate for ... for RTD, mA or V ranges Outputs Options Control Alarm Relays Contacts SPDT 2 Amp ... at 240V AC, 500,000 operations Control SSR Driver Outputs Drive capability 10V ... 10V, 2 to 10V, 0 to 5V into 500W min. Control outputs have 2% over/under drive ... between 2 setpoints or Auto/Manual control. Volt free or TTL input Remote Setpoint ...
|
| | M9610-W08 Dual Relay M9610-W09 Program Control Inputs N9440G010 (4400 Programmer) ...
|