23 results for industrial fitting found in 0.004 seconds

 

Catalog: West Brand Product Catalog
Company/Brand: Danaher Industrial Controls


 

6 West brand Control Basics: This section is intended to help you make a selection if you are uncertain which type of controller is most appropriate for your application. INPUT TYPE An automatic process controller needs to measure the controlled variable continuously in order to take the appropriate action in controlling the process. In temperature applications, either a thermocouple or RTD can be used. Considerations such as maximum temperature, and the harshness of the environment are important. For non temperature applications, the input signal is usually supplied by a signal conditioner, i.e.: ...


 

8 West brand Control Basics: Auto-Manual Control Auto-Manual Control allows control of the process to be switched from automatic (or closed loop control), to manual (or open loop control). In Manual mode the operator is able to adjust the power to the load from zero to maximum, which is useful when first commissioning a system or troubleshooting. On switchback to Auto, the transfer is bumpless, the controller takes over control of the process without introducing a control disturbance. ADDITIONAL FEATURES Remote Setpoint This feature enables an externally generated analog signal (4-20mA DC, 1-5V ...


 

9 West brand Control Basics: TUNING THE CONTROLLER MANUALLY Controllers Fitted with Output 1 Only Before starting to tune the Controller to the load, check that the Setpoint High and Low Limits (SPhi and SPLo) are set to safe levels. The following simple technique may be used to determine values for proportional band (Pb1), derivative time constant (rAtE) and integral time constant (rSEt). NOTE: This technique is suitable for use only with processes which are not harmed by large fluctuations in the process variable. It provides an acceptable basis from which to start fine tuning for a wide range ...


 

10 West brand Control Basics: Controllers Fitted with Output 1 and Output 2 Before starting to tune the Controller to the load, check that the Setpoint High and Low Limits (SPhi and SPLo) are set to safe levels. The following simple technique may be used to determine values for proportional band (Pb1), derivative time constant (rAtE) and integral time constant (rSEt). NOTE: This technique is suitable for use only with processes which are not harmed by large fluctuations in the process variable. It provides an acceptable basis from which to start fine tuning for a wide range of proceses. 1. Tune ...


 

: These products are sold by Danaher Industrial Controls under the warranties set forth ... new merchandise, directly from Danaher Industrial Controls or from a West Brand product ... HEREIN AND ABOVE SET FORTH. DANAHER INDUSTRIAL CONTROLS MAKES NO WARRANTY OF ... TO THE PRODUCTS. Limitations Danaher Industrial Controls shall not be liable for any ... through a third party without Danaher Industrial Controls authorization. Returns Danaher ... Industrial Controls' sole and exclusive obligation ... to repairing or replacing (at Danaher Industrial Controls option) free of charge, the ... are reported in writing to Danaher Industrial Controls at its main office indicated ... below. Danaher Industrial Controls is to be advised of return ... for products returned and Danaher Industrial Controls or its representative shall ...


 

20 West brand 6010 Order Matrix: Order Code N 6 0 1 1 - Z 1 Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 Type 1 Relay Alarm output Output 2 Type 0 Not fitted 1 Relay Recorder Output 3 Type 0 Not fitted 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA Options 02 24VAC/DC Power Supply 30 Remote Lock 32 Remote Lock and 24VAC/DC Power Supply


 

24 West brand 6100+ Order Matrix: P 6 1 0 1 Z INPUT TYPE 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage OUTPUT 1 0 Not Fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 Triac OUTPUT 2 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 Triac OUTPUT 3 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 Transmitter Power Supply DISPLAY COLOR 0 Red Upper Lower 1 Green Upper Lower 2 Red Upper, Green Lower 3 Green Upper, RedLower POWER SUPPLY 0 100-240V AC 2 24-48V AC/DC OPTIONS ...


 

28 West brand 6170 Order Matrix: Order Code N 6 1 7 1 Z Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 and 2 11 Relay and Relay 88 Triac and Triac Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mARecorder Output 5 DC 0-5V 7 DC 4-20mA 8 Triac Options 10 RS-485 2 wire serial communications 02 24VAC/DC Power Supply 12 RS-485 Serial Communication and 24VAC/DC Power Supply 30 Dual Setpoint 32 Dual Setpoint and 24VAC/DC Power Supply


 

32 West brand 6400 Order Matrix: Order Code N 6 4 0 1 Z Model Standard Configuration Input Type 1 RTD or DC mV 2 Thermocouple 3 DC mA 4 DC V Output 1 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Output 2 0 Not Fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Output 3 0 Not Fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Output 4 10 RS-485 2 Wire Serial Comms 02 Line voltage 24V AC/DC 12 RS-485 2 Wire Serial Comms and Line Voltage 24V AC/DC 30 Remote run/hold (digital input) 32 Remote run/hold (digital ...


 

36 West brand 6500 Order Matrix: Order Code N 6 5 0 1 Z 0 Model Standard Configuration Input Type 1 RTD 2 Thermocouple Output Type 1 Relay 2 SSR Drive Alarm 0 Not fitted 1 Relay Constant Line Supply 0 90-264V AC 2 24 V AC/DC NOTES: 1. The RTD 0.0 range will always be 0.0 99.9, whatever the Range Maximum setting may be. 2. Absolute range maximum 400° C (700° F). 3. Input Sensor Type is defaulted to Thermocouple, Type J/L, F, and the Input Range Maximum is defaulted to 100.


 

40 West brand 6600 Order Matrix: Order Matrix: N 6 6 0 1 - Z Model Standard Configuration Input Type 1 3 Wire RTD 2 Thermocouple Output 1 (Heat Output) 1 Relay 2 DC for SSR 8 Triac Output 2 (Cool Output/alarms and/or Heater Break) 0 Not fitted 1 Relay 2 DC for SSR 8 Triac 9 Dual Relay Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 12 RS-485 Serial Communication and 24VAC/DC Power Supply 30 Dual Setpoint 32 Dual Setpoint and 24VAC/DC Power Supply


 

44 West brand Order Matrix: 6700 Order Matrix: Order Code N 6 7 0 1 - Z Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 1 Relay Output 2 0 Not fitted 1 Relay Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 3 DC 0-10V 4 DC 0-20mARecorder Output 5 DC 0-5V 7 DC 4-20mA Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 30 Remote Reset Input 12 RS-485 Serial Communication and 24VAC/DC Power Supply 32 Remote Reset Input and 24VAC/DC Power Supply


 

46 West brand 8010 1/8 DIN Indicator The 8010 is an 1/8 Din Indicator that provides good visible indication for almost all applications, and is available in either red or green. This indicator also comes with several alarm strategies including latching and non-latching outputs. Relay output is standard with a second and third alarm possible. Each alarm has its own LED indicator for fast identification of alarms. Configuration is simple, either through manual setup from the front panel or directly via a configuration port from a PC using dedicated West software. Unauthorized user can also be locked ...


 

48 West brand 8010 Order Matrix: Order Code N 8 0 1 1 - Z 1 J Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Relay Output 1 1 Relay Alarm output Output 2 Type 0 Not fitted 1 Relay 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA Output 3 Type 0 Not fitted 1 Relay 8 Transmitter Power Supply Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 30 Remote Reset 12 RS-485 Serial Communication and 24VAC/DC Power Supply 32 Remote Reset and 24VAC/DC Power Supply LED Color Blank Red LEDs 1 Green LEDs


 

54 West brand 8100+ Order Matrix: P 8 1 0 1 Z INPUT TYPE 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage OUTPUT 1 0 Not Fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 Triac* OUTPUT 2 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 Triac* OUTPUT 3 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 24V Transmitter PSU OPTION SLOT A 0 Not fitted 1 RS485 Serial Comms 3 Dual Setpoint 4 Basic Remote Setpoint SUPPLY VOLTAGE 0 100-240 VAC 2 24-48 AC or DC DISPLAY COLOR 0 ...


 

58 West brand 8170 Order Matrix: Order Code N 8 1 7 1 Z Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 and 2 11 Relay and Relay 88 Triac and Triac Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mARecorder Output 5 DC 0-5V 7 DC 4-20mA 8 Triac Options 10 RS-485 2 wire serial communications 02 24VAC/DC Power Supply 12 RS-485 Serial Communication and 24VAC/DC Power Supply 30 Dual Setpoint 32 Dual Setpoint and 24VAC/DC Power Supply


 

62 West brand 8200 Order Matrix: Order Code N 8 2 0 1 - Z Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac (Consult Factory) Output 2 (Alarm 2 or Control Output 2) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 30 Dual Setpoint Switching 12 ...


 

66 West brand 8600 Order Matrix: Order Matrix: N 8 6 0 1 - Z Model Standard Configuration Input Type 1 3 Wire RTD 2 Thermocouple Output 1 (Heat Output) 1 Relay 2 DC for SSR 8 Triac Output 2 (Cool Output/alarms and/or Heater Break) 0 Not fitted 1 Relay 2 DC for SSR 8 Triac 9 Dual Relay Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 12 RS-485 Serial Communication and 24VAC/DC Power Supply 30 Dual Setpoint 32 Dual Setpoint and 24VAC/DC Power Supply*


 

70 West brand 4100+ Order Matrix: P 4 1 0 1 Z INPUT TYPE 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage OUTPUT 1 0 Not Fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 Triac* OUTPUT 2 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 Triac* OUTPUT 3 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 6 DC 2-10V 7 DC 4-20mA 8 24V Transmitter PSU OPTION SLOT A 0 Not fitted 1 RS485 Serial Comms 3 Dual Setpoint 4 Basic Remote Setpoint SUPPLY VOLTAGE 0 100-240 VAC 2 24-48 AC or DC DISPLAY COLOR 0 ...


 

74 West brand 4170 Order Matrix: Order Code N 4 1 7 1 Z Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 and 2 11 Relay and Relay 88 Triac and Triac Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mARecorder Output 5 DC 0-5V 7 DC 4-20mA 8 Triac Options 10 RS-485 2 wire serial communications 02 24VAC/DC Power Supply 12 RS-485 Serial Communication and 24VAC/DC Power Supply 30 Dual Setpoint 32 Dual Setpoint and 24VAC/DC Power Supply


 

78 West brand 4200 Order Matrix: Order Code N 4 2 0 1 - Z Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Traic (Consult Factory) Output 2 (Alarm 2 or Control Output 2) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Traic Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Traic Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 30 Dual Setpoint Switching 12 RS-485 ...


 

82 West brand 4400 Order Matrix: Order Code N 4 4 0 1 - Z G Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac (Consult Factory) Output 2 (Alarm 2 or Control Output 2) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 2 DC for SSR 3 DC 0-10V 4 DC 0-20mA 5 DC 0-5V 7 DC 4-20mA 8 Triac Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 12 RS-485 Serial Communication ...


 

86 West brand Order Code N 4 7 0 1 - Z Model Standard Configuration Input Type 1 3 Wire RTD or DC mV 2 Thermocouple 3 DC mA 4 DC Voltage Output 1 1 Relay Output 2 0 Not fitted 1 Relay Output 3 (Alarm 1 or Recorder O/P) 0 Not fitted 1 Relay 3 DC 0-10V 4 DC 0-20mARecorder Output 5 DC 0-5V 7 DC 4-20mA Options 10 RS-485 Serial Communication 02 24VAC/DC Power Supply 30 Remote Reset Input 12 RS-485 Serial Communication and 24VAC/DC Power Supply 32 Remote Reset Input and 24VAC/DC Power Supply 4700 Order Matrix:


 
  Similar searches   parker industrial fittings (17)
parker industrial fittings catalog (11)
parker industrial tube fittings catalog (9)
parker fittings catalog industrial (11)
industrial tube fittings (282)
industrial pipe fittings (172)
industrial pipe fittings by parker (7)
parker industrial tube fittings (13)
1 parker industrial tube fittings ... (9)
armstrong industrial hand tools (64)
parker fittings catalog (281)
delgado community college fitness ... (21)
armstrong industrial tools (68)
a lok r tube fitting (51)
din s fittings (88)
fitting adapters to fit metric s hose ... (31)
button head grease fittings (10)
m12 tube fitting (19)
industrial robot bearings (24)
h7 fit (55)
honda fit (304)
parker fittings (446)
hose fittings parker (19)
copper nickel fittings (85)
hand fitting side seals (125)
master power industrial air tools (54)
banjo fitting (194)
tube fitting brass (525)
dielectric tube fittings (31)
18 pressure fitting (668)
bulkhead fitting (206)
parker tube fittings catalog (244)
orifice fitting (98)
fitted spoiler (159)
6mo fittings (28)
test tube fitting (320)
drive shaft industrial (108)
press fit dowel pin (61)
brass bulkhead fitting (55)
brass bulkhead fittings (55)
honda fit 08 (31)
sä ms fittings (94)
metric tube fittings (216)
cpi tube fittings ss (21)
allied industrial sales (20)
manifold fitting (986)
manifold fitting ford 200 (44)
manifold fitting ford 200 engine (40)
intake manifold vacuum fitting (100)
intake manifold vacuum fitting ford (37)
intake manifold vacuum fitting ford 289 (21)
plumbing fittings (300)
ptfe tube and tube fitting (42)
hose fittings 92 95 civic (8)
parker fitting (445)
a lok cpi fittings (179)
parker fittings locations (16)
parker fittings p series (7)
custom insert fittings (339)
plastic insert fittings (364)



Home | Latest catalogs | Contact

© 2006-2008 by who-sells-it.com