8 West brand Control Basics: Auto-Manual Control Auto-Manual Control allows control of the process to be switched from automatic (or closed loop control), to manual (or open loop control). In Manual mode the operator is able to adjust the power to the load from zero to maximum, which is useful when first commissioning a system or troubleshooting. On switchback to Auto, the transfer is bumpless, the controller takes over control of the process without introducing a control disturbance. ADDITIONAL FEATURES Remote Setpoint This feature enables an externally generated analog signal (4-20mA DC, 1-5V ...
23 West brand 6100+ Brief Specs: Features Control Types Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat only or heat cool Auto/Manual Selectable from front panel or via digital input, with bumpless transfer Output Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint Alarm 1 2 Types Process high, process low, SP deviation, band, logical OR AND. Also 1 loop alarm for process control security. Process alarms have adjustable hysteresis. Human Interface 4 button operation, dual 4 digit 10mm 8mm high LED ...
27 West brand Brief Specs: Inputs: Thermocouple: J, K, R, S, T, B, L, N RTD: Pt 100 DC Linear: 0-20mA, 4-20mA 0-50mV, 10-50mV 0-5V, 1-5V, 0-10V, 2-10V Dual Setpoint: Voltage free contact or TTL compatible Output: VMD Control Outputs: 2 Relays- SPDT 2A at 120V AC (motor drive), 2A at 240V AC (resistive) 2 Triacs- 1amp 40° C, Derate to 1/2amp 80° C Alarm Output: 1 Relay- 2A at 240V AC or 1 SSR 4.2V DC Recorder Output: 0-5V and 0-10V SP PV 500 ohm min. 0-20mA and 4-20mA 500 ohm min. Communications: RS-485 2 wire Control and: Tuning: VMD, Pre-Tune and Self Tune Features Manual Adjustment Facility Proportional ...
39 West brand 6600 Brief Specs: Brief Specs: Inputs: Thermocouple: J, T, K, N, L, R, S, B RTD: Pt 100 Dual Setpoint: Voltage free contact or TTL Output: Control Output: Relay- SPDT 2A at 120/240V AC SSR: 10V DC into 1 KOhm minimum Triac- 1amp 40° C, Derate to 1/2amp 80° C Alarms Option: 1 or 2 alarms plus Heater Break Alarm 2A 120/240V AC or SSR 10V into 500 Ohm minimum Recorder Output: 0-5V and 0-10V Retransmission SP/PV 500 ohm min 0-20mA and 4-20mA 500 ohm min. Communications: RS-485 2 wire-MODBUS or West ASCII Control and: Tuning: Pre-Tune and Self Tune Features Auto/Manual with bumpless transfer ...
43 West brand Brief Specs: Inputs: Thermocouple: J, K, R, S, T, B, L, N RTD: Pt 100 DC Linear: 0-20mA, 4-20mA 0-50mV, 10-50mV 0-5V, 1-5V, 0-10V, 2-10V Remote Reset: Voltage free contact or TTL compatible Output: Limit Outputs: Relay- SPDT 5A at 240V AC Alarm Outputs: 2 Alarms as standard Relay- SPDT 2A at 120/240V AC Recorder Output: 0-5V and 0-10V Retransmission SP/PV 500 ohm min 0-20mA and 4-20mA 500 ohm min. Communications: RS-485 2 wire Control: On Off Control: Manual Reset Operating and: Accuracy: 0.25% of span 1 LSD Environmental Ambient Temperature: 0° C to 55° C (Operating) -20° C to 80° ...
53 West brand 8100+ Brief Specs: Brief Specs: Features Control Types Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat only or heat cool Auto/Manual Selectable from front panel or via digital input, with bumpless transfer Output Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint Alarm 1 2 Types Process high, process low, SP deviation, band, logical OR AND. Also 1 loop alarm for process control security. Process alarms have adjustable hysteresis. Human Interface 4 button operation, dual 4 digit 10mm ...
57 West brand Brief Specs: Inputs: Thermocouple: J, K, R, S, T, B, L, N RTD: Pt 100 DC Linear: 0-20mA, 4-20mA 0-50mV, 10-50mV 0-5V, 1-5V, 0-10V, 2-10V Dual Setpoint: Voltage free contact or TTL compatible Output: VMD Control Outputs: 2 Relays- SPDT 2A at 240V AC 5 X 10 5 operations (resistive) 2 Triacs- 1amp 40° C, Derate to 1/2amp 80° C Alarm Output: 1 Relay- 2A at 240V AC or 1 SSR 4.2V DC Recorder Output: 0-5V and 0-10V SP PV 500 ohm min. 0-20mA and 4-20mA 500 ohm min. Communications: RS-485 2 wire Control and: Tuning: VMD, Pre-Tune and Self Tune Features Manual Adjustment Facility Proportional ...
65 West brand 8600 Brief Specs: Brief Specs: Inputs: Thermocouple: J, T, K, N, L, R, S, B RTD: Pt 100 Dual Setpoint: Voltage free contact or TTL Output: Control Output: Relay- SPDT 2A at 120/240V AC SSR: 10V DC into 1 KOhm minimum Triac- 1amp 40° C, Derate to 1/2amp 80° C Alarms Option: 1 or 2 alarms plus Heater Break Alarm 2A 120/240V AC or SSR 10V into 500 Ohm minimum Recorder Output: 0-5V and 0-10V Retransmission SP/PV 500 ohm min 0-20mA and 4-20mA 500 ohm min. Communications: RS-485 2 wire-MODBUS or West ASCII Control and: Tuning: Pre-Tune and Self Tune Features Auto/Manual with bumpless transfer ...
69 West brand 4100+ Brief Specs: Brief Specs: Features Control Types Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat only or heat cool Auto/Manual Selectable from front panel or via digital input, with bumpless transfer Output Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint Alarm 1 2 Types Process high, process low, SP deviation, band, logical OR AND. Also 1 loop alarm for process control security. Process alarms have adjustable hysteresis. Human Interface 4 button operation, dual 4 digit 13mm ...
73 West brand Brief Specs: Inputs: Thermocouple: J, K, R, S, T, B, L, N RTD: Pt 100 DC Linear: 0-20mA, 4-20mA 0-50mV, 10-50mV 0-5V, 1-5V, 0-10V, 2-10V Dual Setpoint: Voltage free contact or TTL compatible Output: VMD Control Outputs: 2 Relays- SPDT 2A at 240V AC 5 X 10 5 operations (resistive) 2 Triacs- 1amp 40° C, Derate to 1/2amp 80° C Alarm Output: 1 Relay- 2A at 240V AC or 1 SSR 4.2V DC Recorder Output: 0-5V and 0-10V SP PV 500 ohm min. 0-20mA and 4-20mA 500 ohm min. Communications: RS-485 2 wire Control and: Tuning: VMD, Pre-Tune and Self Tune Features Manual Adjustment Facility Proportional ...
85 West brand Brief Specs: Inputs: Thermocouple: J, K, R, S, T, B, L, N RTD: Pt 100 DC Linear: 0-20mA, 4-20mA 0-50mV, 10-50mV 0-5V, 1-5V, 0-10V, 2-10V Remote Reset: Voltage free contact or TTL compatible Output: Limit Outputs: Relay- SPDT 5A at 240V AC Alarm Outputs: 2 Alarms as standard Relay- SPDT 2A at 120/240V AC Recorder Output: 0-5V and 0-10V Retransmission SP/PV 500 ohm min 0-20mA and 4-20mA 500 ohm min. Communications: RS-485 2 wire Control: On Off Control: Manual Reset Operating and: Accuracy: 0.25% of span 1 LSD Environmental Ambient Temperature: 0° C to 55° C (Operating) -20° C to 80° ...