Spectracular 2017 by Eppendorf

More catalogs by Eppendorf | Spectracular 2017 | 14 pages | 2017-05-23

Ads

Contacts for Eppendorf

Eppendorf AG
Barkhausenweg 1
22339 Hamburg
Deutschland

Phone: ++ 49 40 53 801-0
Fax: ++ 49 40 53 801-556
eMail: eppendorf@eppendorf.de
http://www.eppendorf.com/

Spectracular 2017 is listed under these categories

Industrial Supply > Laboratory Equipment

Featured catalog pages of Spectracular 2017

new eppendorf biophotometer® d30 eppendorf biospectrometer® fluorescence spectracular spectracular performance eppendorf photometer and

with the maximum level of flexibility eppendorf photometry products are equipped to handle a wide range of

eppendorf detection family 3 »eppendorf continues a longstanding tradition with over 60 years of experience in the field of photometry.« in 1950 eppendorf brought its first photometer to the market from the very beginning the focus was on obtaining maximum benefits while using the simplest handling methods this philosophy has remained unchanged to this day take advantage of our expertise by achieving optimum results in your laboratory discover new possibilities the biospectrometer fluorescence combines uv/vis and fluorescence methods sensitive sample quantification beyond the photometric detection limit the simplest handling and guided method procedures to make your work even easier take advantage of the possibilities preprogrammed applications for a quick start and minimal errors automatic evaluation of measurement data and clear presentation of results direct storage of measurement data in the device prevents loss of data expand your possibilities the perfect

preprogrammed methods automatic evaluation of measurement data and clear presentation of results simplest handling guided software procedures and operation directly on the device make your work even easier eppendorf biospectrometer® basic with the eppendorf biospectrometer basic measurements can be executed in the uv and vis range from 200 nm to 830 nm the freely selectable wavelengths offer you maximum flexibility during these procedures optimized menu navigation guides you through the individual methods in a step-by-step process all required entries are visible right away the entire operating procedure is guided by a help box that explains each individual step www.eppendorf.com/detection product benefits uv/vis spectral range of 200 nm to 830 nm preprogrammed applications for quick start guided software procedure and operation directly on the device automatic storage of measuring results 1,000 integrated data processing option for specific

retrospective modification of the time window for regression analysis with corresponding kinetic methods integrated freely temperaturecontrolled cuvette shaft for determining enzyme and substrate kinetics eppendorf biospectrometer® kinetic as an expansion of the biospectrometer basic the eppendorf biospectrometer kinetic features a temperature-controlled cuvette shaft the integrated peltier element guarantees high-precision temperature control in addition to the wide range of methods available on the biospectrometer basic the biospectrometer kinetic software offers preprogrammed and freely programmable kinetic methods www.eppendorf.com/detection product benefits all biospectrometer basic options preprogrammed and freely programmable kinetic methods retrospective modification of the time window for regression analysis temperature-controlled cuvette shaft adjustment range +20 °c to +42 °c in 0.1 °c

uv/vis absorption measuring range of 200 nm to 830 nm combined with a fluorescence intensity of 0.5 nm to 2,000 nm fluorescein combination of uv/vis and fluorescence measurements in a single device eppendorf biospectrometer® fluorescence the integrated fluorescence unit of the biospectrometer fluorescence can be used to increase the measuring range by a factor of 1,000 for example to detect dna this enables reliable quantification up to a concentration of 1.0 pg/μl measurements can be flexibly executed in the uv/vis or fluorescence range what s more quantifications can be carried out using fluorescence dyes in the same device even well beyond the photometric detection limit www.eppendorf.com/detection product benefits all biospectrometer basic options preprogrammed and freely programmable fluorescence methods fluorescence intensity across a range of 0.5 nm to 2,000 nm fluorescein fluorescence excitation wavelength 470 nm emission wavelengths 520 nm and 560

relevant ratios are automatically determined and displayed preprogrammed applications with evaluations via factor standard or standard series for a quick start eppendorf biophotometer® d30 the eppendorf biophotometer d30 is the third generation of eppendorf s well-established biophotometers the measurement data will be recorded for fixed wavelengths small clearly processed data volumes make evaluating results fast and simple for specific methods additional measurement data will be recorded in a defined measuring range and displayed extrapolated making impurities in the sample easier and quicker to identify www.eppendorf.com/detection product benefits fixed wavelengths at 230 nm 260 nm 280 nm 320 nm 340 nm 405 nm 490 nm 562 nm 595 nm and 600 nm display of purity scans extrapolated measurement data for specific applications preprogrammed applications for a quick start applications with evaluations via factor standard or standard series all relevant ratios are automatically

8 eppendorf detection family eppendorf μcuvette® g1.0 with an optical path length of only 1 mm the μcuvette g1.0 features a light path that is ten times shorter than the light path on standard cuvettes this allows high nucleic acid and protein concentrations to be measured using the μcuvette g1.0 only 1.5 μl of a sample is required for the measurement the μcuvette g1.0 offers a flexible expansion of the photometric application range of eppendorf photometers product benefits microvolume measuring cell for measuring 1.5 –10 μl sample volumes concentration determination of nucleic acids and proteins measurement of high sample concentrations without prior dilution exclusively available for eppendorf biophotometer and eppendorf biospectrometer use our cuvette navigator to find the right cuvette for your application www.eppendorf.com/detection uvette® the patented eppendorf uvette is a fully uv-transparent single use cuvette made of clear plastic with

eppendorf detection family 9 vis cuvettes the eppendorf vis cuvettes are disposable cuvettes made of clear plastic with a light transmission of 300 nm to 900 nm the vis cuvettes are the perfect tool for applications outside of the uv range for example colorimetric protein assays bradford lowry etc determining of the optical density of bacterial cultures od600 methods and kinetic and fluorescence measurements based on the volume you would like to measure you can select a semi-micro or a macro cuvette product benefits vis measurements from 300 to 900 nm suitable for colorimetric protein assays od600 and kinetic and fluorescence measurements two different cuvette sizes semi-micro and macro for a wide variety of volumes use our cuvette navigator to find the right cuvette for your application www.eppendorf.com/detection filter sets the secondary uv/vis reference filter set is used to verify the photometric and wavelength systematic errors according to nist® national institute

10 eppendorf detection family history eppendorf has developed an impressive level of expertise through it contributions to the field of photometry eppendorf brought its first photometer on the market over 60 years ago with its current product portfolio eppendorf allows you to select the optimal combination of devices and accessories from a large rapidly expanding range of products from fluorescence-based applications to microvolume measurements anything is possible 1950 1955 1968 1972 1992 1998 2000 2007 2013 2013 photometer »medeor« spectrophotometer photometer ecom 6122 2011 eppendorf biospectrometer® basic/kinetic flame photometer eppendorf eppendorf biophotometer® 6131 2012 eppendorf µcuvette® g1.0 photometer 1101 and 1102 uvette® eppendorf biospectrometer® fluorescence digital photometer 6114 / 15 eppendorf biophotometer® plus eppendorf biophotometer®

eppendorf detection family 11 technical data of instruments biospectrometer basic biospectrometer kinetic absorption light source fluorometer light source – – led – 8.5 mm absorption measuring principle single-beam absorption spectrophotometer with reference beam – absorption beam receiver fluorometer beam receiver biophotometer d30 xenon flash lamp height of light source fluorometer measuring principle biospectrometer fluorescence – confocal filter fluorometer with reference beam cmos photodiode array – wavelength range absorption – single-beam absorption photometer with reference beam – cmos photodiodes photodiodes scan nm 200–830 at 1 nm increments – fixed wavelengths nm 230 260 280 320 340 405 490 562 595 600 fluorometer excitation wavelength – – 470 nm bandwidth 25 nm – fluorometer emission wavelengths – – 520 nm bandwidth 15 nm 560 nm bandwidth 40 nm – temperature

eppendorf detection family 12 cuvette technical data eppendorf µcuvette® g1.0 uvette® macro vis cuvettes semi-micro vis cuvettes dsdna uv concentration range 25 ng/µl–1,500 ng/µl 2.5 ng/µl–750 ng µl – – colorimetric protein assays ✓ ✓ ✓ ✓ od 600 methods – fluorescence measurements ✓ ✓ ✓ ✓ uv transparency 180 nm 220 nm light transmission 180 nm–2,000 nm 220 nm–1,600 nm dimensions w × d × h 12.5 mm × 12.5 mm × 48 mm 12.5 mm × 12.5 mm × 36 mm temperature control – – ✓ – minimum filling volume in eppendorf photometers in devices from other manufacturers 1.5 µl – 50 µl 50 µl 1,000 µl 2,500 µl 400 µl 1,500 µl maximum filling volume 10 µl 2,000 µl 4,500 µl 3,000 µl ✓ ✓ ✓ – – 300 nm–900 nm 12.5 mm × 12.5 mm × 45 mm optical path lengths 1

eppendorf detection family 1 ordering information description eppendorf µcuvette® g1.0 eppendorf microvolume measuring cell for eppendorf biophotometer® and eppendorf biospectrometer® eppendorf biophotometer® d30 – 230v/50–60hz mains plug for europe additional mains/power connections available – 120v/50–60hz mains plug for north america eppendorf biospectrometer® basic – 230v/50–60hz mains plug for europe additional mains/power connections available – 120v/50–60hz mains plug for north america eppendorf biospectrometer® kinetic – 230v/50–60hz mains plug for europe additional mains/power connections available – 120v/50–60hz mains plug for north america eppendorf biospectrometer® fluorescence – 230v/50–60hz mains plug for europe additional mains/power connections available – 120v/50–60hz mains plug for north america eppendorf µcuvette® g1.0

your local distributor www.eppendorf.com eppendorf ag · 22331 hamburg · germany eppendorf@eppendorf.com · www.eppendorf.com www.eppendorf.com/detection eppendorf® the eppendorf logo uvette® eppendorf μcuvette® eppendorf biospectrometer® and eppendorf biophotometer® are registered trademarks of eppendorf ag germany nist® is a registered trademark of national institute of standards and technology usa · all rights reserved including graphics and images u.s design patents are listed on www.eppendorf.com/ip · order no a61xx12020/gb2/3t/0515/nw/stef · printed carbon-neutral in germany · copyright © 2013-2015 by eppendorf