GN Resound Canta 2 Completely in the Canal 210 Technical Guide by Hearing Planet
|
|
|
Searched and found1996 technical data 2 base 2 inputs 26 in 31 db gain ansi 80 3 battery voltage test bloomington in bloomington mn canal canals comfort guide comfort shell complete complete shell completely in the canal completion db response faceplate g 50 gn gn 250 gn 80 gn resound gn resound canta gn resound canta 2 cic hearing canta hearing data sheet hearing instrument canta hearing instrument canta batteries hearing planet hls hr 22 igs in key 2 low range high range model 10a model 210 model 888 ms excel ontario pure tone resound resound 250 resound canta resound v spl spl 250 technic technical technical data technical guide technical parameter technics
|
Similar catalogs to GN Resound Canta 2 Completely in the Canal 210 Technical Guide
|
GN Resound Canta 2 Completely in the Canal 210 Technical Guide is listed here
|
Selected page of GN Resound Canta 2 Completely in the Canal 210 Technical Guide
product information canta2 cic product description the canta2 series model 210 is a fully digital completely-in-the-canal cic hearing instrument based on the exclusive gn resound dsp platform the instrument features cochlea dynamics sound processing for excellent speech clarity and hearing comfort model 210 6-band compression system syllabic compression threshold compression ratio attack time release time input limiting threshold compression ratio attack time release time 45 db spl in each band 1.0 to 3.0 5 ms 70 ms 120 ms at 250 hz 75 to 100 db spl >15.0 5 ms 70 ms key features · cochlea dynamics sound processing · 6-band full dynamic range compression · audiogram fitting rule · feedback manager standard configuration program dependent in each handle fitting range 250 0 500 frequency hz 1000 2000 4000 6000 · transparent removal cord · size 10a battery options 20 · 3 different faceplate colors · red and blue transparent shells 40 db hl 60 80 100 120
| technical data canta2 cic technical specifications full-on gain 50 db spl input max 1600 hz hfa max 1600 hz hfa 500 hz 800 hz 1600 hz 2cc coupler 39 db 31 db 33 db 107 db spl 104 db spl 104 db spl 0.5 0.5 0.5 26 db spl 2006300 hz 1.0 ma 70 hrs model 210 in reference to ansi s3.22-1996 supply voltage 1.3 v ospl90 90 db spl input total harmonic distortion input/output response frequency 2khz 120 110 100 output 90 db spl 2cc coupler equivalent input noise frequency range current drain 65 db spl at 1000 hz 1.3 v typical battery life type 10a 80 70 60 50 60 70 80 90 100 110 input db spl maximum output ospl 90 120 110 100 output 90 db spl 80 2cc coupler full-on and reference test gain 50 40 30 gain 20 db 2cc coupler 15113300 rev a canta2 210 specification sheet ©2002 gn resound north america 0203.29 full-on gain 50 db spl input 70 60 50 100 1000 frequency hz 10 0 -10 10000 100 reference test gain 60 db spl input 1000 frequency hz 10000 gn resound north america 8001 bloomington freeway b
|
|
|
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Hearing Planet.
|