aero 11 tm cic digital hearing instrument with 15-channel digital multimode signal processing dmsp digital noise canceler for comfort and ease of listening in noisy environments plus other features for convenient and successful operation dnc key data max gain max power output frequency range general features ear simulator 49 db 124 db spl <1007100 hz 1 5 4 cic battery size 10a tactronic program selection switch the tactronic program selection switch can be deactivated by software 2 3 processing features technical features 2 rsd ad converters 14 bit resolution sampling rate 16 khz 16 bit dual harvard signal processing chip 128 point fft processor fitting range 0 10 20 30 40 50 60 70 80 90 100 110 120 db hl 125 250 500 1000 2000 4000 hz mild to moderate hearing loss all audiometric configurations digital aero product information aero 11 15-channel digital multimode signal processing dmsp 3 signal processing strategies dwdrc non-linear dsc linear dlimiting linear
|
connecting the programming cable open the battery compartment and lift the cover out of the hinge using the battery compartment tool twisting motion connect the cable attach the cables with the blue and red markers to the left and right hearing instruments respectively 027-0354-02/0102/fag printed in switzerland © phonak ag all rights reserved
|
ear simulator data en iec 60118 and iec 60711 2 cm3 coupler data ansi s3.22-1996 output sound pressure level input 90 db spl output sound pressure level 1600 hz input 90 db spl maximum maximum hfa 124 db spl db spl 119 db spl frequency response input 90 db spl 114 db spl <117 db spl db spl 130 120 110 100 90 80 111 db spl frequency response input 90 db spl 130 120 110 100 90 80 100 200 500 1000 2000 5000 10 000 hz 100 200 500 1000 2000 5000 10 000 hz acoustic gain input 50 db spl acoustic gain maximum 49 db db 50 40 30 20 10 0 100 200 500 1000 2000 5000 10 000 hz 1600 hz rtg input 50 db spl 40 db 33 db frequency response full-on-gain input 50 db spl reference test gain input 60 db spl maximum 40 db db 50 40 30 20 10 0 100 200 hfa 35 db rtg 34 db frequency response max gain input 50 db spl reference test gain input 60 db spl fog 7 db 500 1000 2000 5000 10 000 hz frequency range din 45605 total harmonic distortion <1007100 hz 500 hz 2.0 quiescent 1.0 ma 800 hz 2.0 working 1.0 ma 28
|
2 cm3 coupler data input output characteristics at 2000 hz p out db spl full-on-gain reference test gain 130 120 110 100 90 80 30 40 50 60 70 80 90 100 p in db spl measured in dlimiting mode gb 0102 data subject to change without notice.
|