12 point socket 12 sockets 12s 1996 technical data 8 point bit ansi 80 are 12 arrow mounts arrow points battery cover battery covers broadband canal canals check hearing instrument comfort guide delta 4000 delta 4000 technical data door guide easy soft pro fag fitting socket 12 fnc gb 500 hi pro hi pro fitting hi pro fitting hardware in key delta fors mpos noah noah 20 software noah hi pro noise cancel noise cancellation optimizer microphone pcs 12 perseo phonak push to connect serial numbers sigma 6 socket 1 12 socket converter squelch technic technical technics

Similar catalogs to Phonak Perseo In the Canal 12 Technical Guide

Phonak Perseo In the Canal 12 Technical Guide is listed here

Selected page of Phonak Perseo In the Canal 12 Technical Guide

perseo 12 tm with personallogic semi modular mini canal perseo personal digital hearing instrument featuring unique digital microphone technology perseo provides personally optimized clarity comfort convenience and control for easy listening in all hearing situations thanks to personal system managers dpp2 in 20 critical bands fine-scale noise canceler in 20 bands and automatic listening situation manager personal direct control option with the tactronic switch and digital volume control key data max gain max power output frequency range general features ­ ­ ­ ­ ear simulator 50 db 119 db spl <100­7200 hz 3 1 7 2 6 4 mini canal with battery size 10 digital microphone digital volume control end of battery life indicator with acoustic beeps 1 2 5 options ­ tactronic program selection switch ­ confirmation beeps for program selection ­ listening situation manager for automatic soft switching between programs ­ up to three hearing programs mute mode 1 quietsituations 2 noisysituations 3


connecting the programming cable the programming socket is located inside the battery compartment note the battery door does not have to be removed to connect the programming plug it may be necessary however to remove it to program the instrument when inserted into the ear points 1 and 3 to remove the battery cover open the battery cover perpendicular to the instrument and push gently in the direction of the arrow the battery may be left inside the battery cover press the plug into the battery compartment until it connects properly note the correct orientation the blue coded cable will program only a left instrument and the red coded cable will program only a right instrument to re-attach the battery cover after the programming cable has been removed position the battery cover over the hinge and press it gently into place check that the battery cover can be opened and closed without force important the left battery cover with a blue printed inside must be mounted on a left instrume


ear simulator data en iec 60118 and iec 60711 2 cm3 coupler data ansi s3.22-1996 output sound pressure level input 90 db spl output sound pressure level 1600 hz input 90 db spl maximum maximum hfa 119 db spl db spl 110 db spl frequency response max gain input 90 db spl 108 db spl <111 db spl db spl 110 100 90 80 70 60 103 db spl frequency response max gain input 90 db spl 120 110 100 90 80 70 100 200 500 1000 2000 5000 10 000 hz 100 200 500 1000 2000 5000 10 000 hz acoustic gain input 50 db spl acoustic gain maximum 50 db db 60 50 40 30 20 10 100 200 500 1000 2000 5000 10 000 hz 1600 hz 40 db rtg fog­7db 33 db input 50 db spl maximum 40 db db 50 40 30 20 10 0 100 200 hfa 32 db rtg 26 db frequency response max gain input 50 db spl reference test gain input 60 db spl fog­7 db frequency response full-on-gain input 50 db spl reference test gain input 60 db spl 500 1000 2000 5000 10 000 hz frequency range din 45605 total harmonic distortion <100­7200 hz 500 hz 0.5 quiescent 0.55 ma 800 hz


2 cm3 coupler data input output characteristics at 2000 hz p out db spl full-on-gain reference test gain 110 100 90 80 70 60 30 40 50 60 70 80 90 100 p in db spl testmode special program exclusively designed for coupler measurements with perseo ­ access in pfg main menu hearing instruments measurement settings db spl max gain and mpo input 90 db spl 2cc measurement settings input 60 db spl 120 110 100 90 80 70 60 50 40 30 100 200 500 1000 2000 5000 10000 hz due to the complex digital signal processing of this instrument standard measurements with receiver 26a04 as presented in this product information are only possible in a special program gb 0103 data subject to change without notice.