Siemens Phoenix Pro 2 Technical Data by Hearing Planet

Catalogue: Hearing Planet Siemens Phoenix Pro 2 Technical Data
View catalog online
Catalog: Siemens Phoenix Pro 2 Technical Data
Company/Brand: Hearing Planet

Flippable HTML catalog (fast)

PDF catalog (slow, but downloadable)

Flippable Flash catalog (very slow, but cool)

Visitor statistics

Searched and found

1996 technical data ansi 80 ccm channel master data dual compression g 50 g2 hearing planet ite mc 2 mc 35 mc 47 mc 90 microphone noise reduction model t 2 nj 320 phoenix pro pro 111 siemen siemens siemens brochures siemens hearing siemens phoenix siemens products t coil technic technical technical data technical parameter technics toggle switch

Similar catalogs to Siemens Phoenix Pro 2 Technical Data

Siemens Phoenix Pro 2 Technical Data is listed here

Selected page of Siemens Phoenix Pro 2 Technical Data

preliminary phoenix pro 2 ite 125/55/03 fitting range 0 20 40 60 hearing loss 80 80 100 db 120 0.125 70 0.5 1 2 3 4 khz 8 12 60 0.125 0.25 0,5 1 f 1.6 2 2.5 4 khz 8 lo 130 db 120 110 100 90 fog li 50 db oslp 90 li 90 db ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain g 80 db 70 60 50 40 30 20 10 g 70 db 60 50 40 30 20 10 kemar maximum insertion gain 0 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 120/50/03 fitting range 0 20 40 60 hearing loss 80 80 100 db 120 0.125 70 0.5 1 2 3 4 khz 8 12 lo 130 db 120 110 100 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain 80 db 70 oslp 90li 90 60 50 40 fogli 50 db 30 20 0.5 1 f 1.6 2 2.5 4 khz 8 10 g g 60 db 50 40 30 20 10 0 kemar maximum insertion gain 60 0.125 0.25 -10 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8


preliminary phoenix pro 2 itc 120/45/03 fitting range 0 20 40 60 90 hearing loss 80 100 db 120 0.125 80 70 0.5 1 2 3 4 khz 8 12 60 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 fogli 50 db 40 30 20 10 20 10 0 -10 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 lo 130 db 120 110 100 ospl 90li 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain 80 db 70 60 50 g g 60 db 50 40 30 kemar maximum insertion gain 120/40/03 fitting range 0 20 40 60 90 hearing loss 80 100 db 120 0.125 80 70 0.5 1 2 3 4 khz 8 12 lo 130 db 120 110 100 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain 80 db 70 ospl 90li 90 60 50 40 30 fogli 50 db 0.5 1 f 1.6 2 2.5 4 khz 8 20 10 g g 60 db 50 40 30 20 10 0 kemar maximum insertion gain 60 0.125 0.25 -10 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8


preliminary phoenix pro 2 itc 115/40/03 fitting range 0 20 40 60 80 hearing loss 80 100 db 120 0.125 70 60 0.5 1 2 3 4 khz 8 12 50 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 fogli 50 db 30 20 10 0 20 10 0 -10 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 lo 120 db 110 100 90 ospl 90li 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain 70 db 60 50 40 g g 60 db 50 40 30 kemar maximum insertion gain 110/35/03 fitting range 0 20 40 60 80 hearing loss 80 100 db 120 0.125 70 60 0.5 1 2 3 4 khz 8 12 lo 120 db 110 100 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain 70 db 60 ospl 90li 90 50 40 30 fogli 50 db 20 10 1 f 1.6 2 2.5 4 khz 8 0 g g 60 db 50 40 30 20 10 0 kemar maximum insertion gain 50 0.125 0.25 0.5 -10 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8


preliminary phoenix pro 2 mc 115/40/00 fitting range 0 20 40 60 80 hearing loss 80 100 db 120 0.125 70 60 0.5 1 2 3 4 khz 8 12 50 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 fogli 50 db 30 20 10 0 20 10 0 ­10 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 lo 120 db 110 100 90 ospl 90li 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain g 70 db 60 50 40 g 60 db 50 40 30 kemar maximum insertion gain 115/35/00 fitting range 0 20 40 60 80 hearing loss 80 100 db 120 0.125 70 60 0.5 1 2 3 4 khz 8 12 lo 120 db 110 100 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain g 70 db 60 ospl 90li 90 50 40 30 fogli 50 db 20 10 0.5 1 f 1.6 2 2.5 4 khz 8 0 g 50 db 40 30 20 10 0 ­10 kemar maximum insertion gain 50 0.125 0.25 ­20 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8


preliminary phoenix pro 2 mc 105/30/00 fitting range 0 20 40 60 80 hearing loss 80 100 db 120 0.125 70 60 0.5 1 2 3 4 khz 8 12 50 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 lo 120 db 110 100 90 fogli 50 db ospl 90li 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain g 70 db 60 50 40 30 20 10 0 g 50 db 40 30 20 10 0 ­10 kemar maximum insertion gain ­20 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8


preliminary phoenix pro 2 cic 115/40/00 fitting range 0.125 0 20 40 60 80 hearing loss 80 100 db 120 70 60 50 0.125 0.25 0.5 1 f 1.6 2.5 4 khz 8 fogli 50 db 30 20 10 0 20 10 0 ­10 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 0.5 1 2 3 4 khz 8 12 lo 120 db 110 100 90 ospl 90li 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain g 70 db 60 50 40 g 60 db 50 40 30 kemar maximum insertion gain 115/35/00 fitting range 0.125 0 20 40 60 80 hearing loss 80 100 db 120 70 60 0.5 1 2 3 4 khz 8 12 lo 120 db 110 100 90 ansi s3.22 ­ 1996/iec 118-7 sspl/ospl 90 gain/full-on gain g 70 db 60 ospl 90li 90 50 40 30 fogli 50 db 0.5 1 f 1.6 2 2.5 4 khz 8 20 10 0 g 50 db 40 30 20 10 0 ­10 kemar maximum insertion gain 50 0.125 0.25 ­20 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8


ansi s3.22 ­ 1996 effect of the agc-i effect of ck control lo 120 db 110 100 90 80 70 60 30 40 50 60 li 70 80 90 100 rtg f 2 khz off,72 66 60 54 48 42 preliminary phoenix pro 2 fitting parameters effect of the agc-o effect of ck control lo 120 db 110 100 -21 db off 3 dbst example directional characteristic 0º 500 hz 1 khz 2 khz 90 80 70 60 30 40 50 60 li 70 80 90 100 f 2 khz fog 270º 90º measured on kemar 180º dynamic compression characteristic type output limiter channel-agc agc-o dual compression fast slow attack time 2 ms 3 ms 500 ms release time 80 ms 30 ms 5 sec the measurements were achieved with ls-i phoenix pro 2 120/50/03 10 db


iec 118-7 frequency response shaping example sloping hearing loss lo 110 db 100 90 80 70 60 50 40 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 g1 minimum li 60 db gref preliminary phoenix pro 2 fitting parameters example reverse hearing loss lo 110 db 100 90 80 70 60 50 40 0.125 0.25 0.5 1 f 1.6 2 2.5 4 khz 8 g2 minimum li 60 db gref normal acoustic response normal acoustic response


iec 118-7 effect of the agc-i effect of ck control lo 120 db 110 100 90 80 70 60 30 40 50 60 li 70 80 90 100 gref f 2 khz off 72 66 60 54 48 42 preliminary phoenix pro 2 fitting parameters effect of the agc-o effect of ck control lo 120 db 110 100 -21 db off 3 dbst 90 80 70 60 30 40 50 60 li 70 80 90 100 f 2 khz fog dynamic compression characteristic type output limiter channel-agc agc-o dual compression fast slow attack time 2 ms 3 ms 500 ms release time 80 ms 30 ms 5 sec the measurements were achieved with phoenix pro 2 ite 120/50/03


fitting parameters parameters gain master gain vc range parameter data preliminary fitting parameters max gain reduction in 3 db steps 16 ­ 0 channel gain 1 max 3 db steps 2 max 3 db steps compression threshold ck 42 48 54 60 66 72 off 42 48 54 60 66 72 off agc-o 0 -3 -6 -9 -12 -15 -18 -21 -12 db


siemens hearing instruments inc locations united states headquarters/northeast manufacturing facility p.o box 1397 piscataway nj 08855-1397 · 732 562-6600 or 800 766-4500 midwest manufacturing facility/professional products 847 808-1200 or 800 333-9083 south manufacturing facility 770 422-4540 or 800 922-9998 west manufacturing facility 714 670-8216 or 800 998-9787 technical support for software and systems 888 231-1333 siemens hearing instruments a division of siemens canada limited 320 pinebush road cambridge ontario canada n3c 2v3 · 519 622-5200 or 800 663-0620 www.siemens-hearing.com/pro information in this brochure subject to change without notice © 2002 siemens hearing instruments inc all rights reserved 07189116 11/02 2.0 22k711 3k shi/05518-2


All copyrights remain by their owners. Who-sells-it.com is not an official partner of Hearing Planet.
 



Home | Latest catalogs | Contact

© 2006-2008 by who-sells-it.com