technical data trianotm technical data important information ... the data contained in this guide trianotm contains an assortment of adaptive ... should always be given to the set up of triano signal processing and test conditions ... has added an important feature to triano that permits the hearing care ... to test the basic functionality of triano using standardized test equipment ... the connexxtm fitting menu configures triano for full-on gain no compression and all ... mode will probably not be used by the hearing impaired individual it does provide a ... benchmark for assessing triano using existing test equipment and ... standards it also permits the hearing instrument to be explained using ... in this guide is the static response of triano to sinusoidal swept tones this data ... multiple signal processing algorithms triano 3 triano s triano sp tm technical ...

application/technical data triano 3 tm description · programmable mid-sized ... · appropriate for mild to severe hearing loss · adaptive directional microphone ... · easy fitting interface using connexx 32-bit programming software amplifier · fully ... directional microphone system with 3 microphones · acoustic indicator when ... typeplates to indicate right and left hearing instruments · type 13 battery triano 3 ... fitting to achieve optimal fitting triano 3 bte behind-the-ear hearing ... instruments are designed specifically for the right ... to distinguish between ears the right hearing instrument will have a red typeplate ... and the left hearing instrument will have a blue typeplate ...
db 65 db 61 db 45 db <100 hz 6,800 hz 3 2 1 18 db <11 db 106 db microphone ... ports progamming socket pushbutton triano 3 tm fig 1 battery battery voltage 1.3 ... ansi battery life type 13 zinc air 1.3 ma 100-200 hrs battery compartment door ...
index db 8 7 measurement on kemar with hearing instrument triano 3 tm directional ... for high frequencies 0° 2 khz 3 khz 4 khz 5 khz 6 5 4 3 2 without ... hearing instrument 1 0 -1 -2 0.125 0.25 ... of microphones it is important that the hearing instrument fits on the ear such that ... the 3 microphones are directed along a ...
standard features operating mode triano 3 bte hearing instrument can be turned ... press the pushbutton and hold for 3 seconds to turn the hearing instrument ... on/off the hearing instrument can also be turned on/off by ... inserting or removing the battery triano 3 bte hearing instrument has 4 ... once program 2 beeps twice program 3 beeps three times and program 4 beeps ... mode 2 select microphone or t-coil mode 3 select microphone or t-coil mode 4 ... the instrument s position on the ear triano 3 tm pushbutton ...
db 54 db 48 db 40 db <100 hz 6,100 hz 3 2 2 18 db 198 db microphone ports ... triano s tm fig 2 battery battery voltage 1.3 ...
coupler ansi s3.22-1996 fitting range triano s lo 0 20 130 db 120 110 40 60 80 100 ... db 120 0.125 100 90 80 70 l i 90 db triano s tm maximum output level g 70 db 60 50 ... 40 30 20 10 0.5 1 f 1.6 2 4 khz 8 maximum ... gain hearing loss db li 50 db main fitting range 0. ... 5 1 2 3 4 khz 8 12 60 0.125 0.25 0 0.125 0.25 0 ... 0° 500 khz 1 khz 2 khz db 4.3 db 9.8 db 7.2 db 7 6 5 4 3 2 1 0 -1 -2 ... without hearing instrument measurement on kemar with ... hearing instrument front-side ratio average ... average data at 180° 270° 10 d b 90° -3 0.125 0.25 measured on kemar 180° left ...

standard features operating mode triano s bte hearing instrument has several ... once program 2 beeps twice and program 3 beeps three times a fourth program ... an audio input boot is coupled to the hearing instrument the hearing instrument beeps ... mode select microphone or t-coil mode triano s tm accessories changing the typeplate ... located on the inner curve of the hearing instrument can be exchanged for red or ... the damper from the earhook siemens triano s ens siem o s n tria 1 t 2 1 program ...
ports earhook volume control 1 t 2 triano sp tm fig 3 battery battery voltage ... battery life type 675 zinc air 1.6 ma 1.3 v programmable connector situation ... door with lock and on/off switch fig 3 right instrument 100-200 hrs audio ... dual compression fast attack release <3 ms 100 ms 9 ms 5 ms 90 ms 90 ms 1.5 s ...
index db 7 6 measurement on kemar 5 4 3 10 db triano sp tm directional ... static 0° 500 hz 1 khz 2 khz with hearing instrument 2 1 0 -1 -2 -3 0.125 0.25 0. ... 5 without hearing instrument 270° 90° measured on kemar ... index ai weighted directivity di 3.8 db 10.0 db 4.6 db front-side ratio ...
standard features operating mode triano sp bte hearing instrument has several ... once program 2 beeps twice and program 3 beeps three times a fourth program ... an audio input boot is coupled to the hearing instrument the hearing instrument beeps ... mode select microphone or t-coil mode triano sp tm accessories changing the ... located on the inner curve of the hearing instrument can be exchanged for red or ... selected volume setting 1 t 2 siemens triano sp 1 t 2 1 program one t t-coil 2 ...

siemens hearing instruments inc locations united states ... products 847 808-1200 or 800 333-9083 south manufacturing facility 770 422- ... and systems 888 231-1333 siemens hearing instruments a division of siemens ... canada limited 320 pinebush road cambridge ontario canada ... 622-5200 or 800 663-0620 www.siemens-hearing.com/p ro information in this brochure ... to change without notice © 2002 siemens hearing instruments inc all rights reserved ... 07087872 12/02 2.0 22k711 3k shi/05579-3 ...