fully digital bte · 3 channel dsp with · loudness mapping · sound stabilizertm · speech enhancement · speech intensification systemtm · in-situ sensogram fitting system · automatic feedback management recommended for · mild to severe hearing losses · all configurations of hearing loss including ski-slope sloping flat and reverse slope losses · people who desire a fully automatic aid with no manual controls suggested fitting range the senso c8 is a 100 digital hearing aid with a dedicated dsp digital signal processor utilizing over 20 bit representation of the signal maximum bit depth is 32 bits and 32 khz sampling frequency senso c8 offers all the senso advantages · 3 channel compression with adjustable crossover frequencies to maximize fitting flexibility · loudness mapping to compensate for
|
recruitment · sound stabilizertm for smooth gain transition · in-situ sensogram fitting to increase accuracy of fit · automatic feedback manager to minimize feedback · speech enhancement algorithm to increase listening comfort and ease in noise · speech intensification systemtm offers additional focus on speech signals in noisy environments · expansion processing to minimize microphone noise · extended input dynamic range to allow input levels of up to 100 db spl without saturation/distortion · automatic output control aoc to ensure low distortion at high output levels · highly efficient ddd digital output amplifier to achieve long battery life 415 hours from a size 13 battery and high mpo 125 db spl · low battery beep-tone indicator to alert battery replacement is needed · separate a/d converter for inductive input to allow equalization for microphone response and adjustable sensitivity · anti-hum filter to minimize line noise i.e 60hz interference · high immunity against interferen
|
a aoc disabled b aoc enabled measurements the advanced signal processing algorithms used in senso make results of direct conventional measurements variable and difficult to interpret special considerations are necessary in making these measurements for quality control and service purposes a special test mode has been defined that allows inspection of the electroacoustic integrity of the hearing aid s components the test mode can be accessed from both the lp2 programmer and the compass software loudness mapping loudness mapping uses an advanced automatic volume control function to provide audibility and comfort for most sounds compared to linear hearing aids soft sounds are amplified more providing a lower aided threshold and loud sounds are amplified less reducing listening strain the widest possible range of sound is preserved within the wearer narrow dynamic range s unlike typical wdrc systems which use fast regulation time to achieve a nonlinear gain function loudness mapping uses
|
conditions they may introduce silent periods if the intensity changes too rapidly sound stablizertm applies dynamic control of the regulation times this yields steady gain in stable environments and rapid gain adaptation to drastic changes in the acoustic environment amplification reduced after a loud noise for instance will quickly return to ensure audibility for soft sounds automatic feedback manager senso is equipped with an automatic feedback manager in each of the three frequency channels it determines how much gain is possible without feedback and limits the maximum gain accordingly this will not influence amplification of normal speech sounds the automatic feedback manager can be adjusted manually to control the kneepoint of the input-output function this affects gain for the very soft sounds it can be used to help new wearers to acclimatize to hearing soft sounds again with reduced amplification initially this process is described in our programming manuals speech enhancement o
|
time to replace the cell telecoil the telecoil and the microphone in senso have separate a/d converters this allows filtering of the inductive input without any analog pre-amplifiers that is why senso can offer both equalization of the telecoil response so that it has the same sensitivity as the microphone and an anti-hum filter to reduce interference from the line input the sensitivity of the telecoil is adjustable this will enhance the benefits from the telecoil when used with weaker inductive loop systems programming all senso hearing aids can be programmed with the small hand-held lp2 programmer and the hi-pro interface with the noah compatible compass software please refer to the programming manuals for details back to top
|