10 x 10 x 12 10 x 10 5 x 10 x 10 plate type heat exchanger ball valve type with stainless steel ball solar heat exchange tube heat exchanger hot water circulating pump heat exchanger plates dn 200 pn 16 dn 400 pn 16 dn 25 pn 16 top hat rail type 2 heat exchanger plate type heat exchangers hot water heating systems variable speed pumps shut off valve ball plate heat exchangers plate heat exchanger water shut off valve 4 way ball valve 6 way ball valve 3 way ball valve 2 way ball valve corrugated stainless steel tubing corrugated stainless steel tubes 10 bar pressure gauge stainless steel pipe stainless steel pipes stainless steel 8 pipe 8 stainless steel pipe stainless steel pipe 2 remote control united non return valve non return valves under floor heating air shut off valve stainless steel pipe 6 mm air shut off valves tube insert in heat transfer control module diagram in c high pressure stainless steel pipe ball of ball valve stainless steel pipe 12 stainless steel pipe 15 mm stainless steel pipe 25 mm stainless steel pipe 20 mm 12 3 way ball valve 25 mm stainless steel pipe stainless steel pipe 10 stainless steel pipe 12 mm screw bolt and nuts self tapping screws stainless steel pipe sizes

Solar Catalogue 2016 is listed under these categories

Home & Garden > Heating Cooling & Air

Featured catalog pages of Solar Catalogue 2016

hoval combisol r 800,1000 solar energy buffer storage tank with integrated calorifier ■■description hoval combisol r 800,1000 • heating support and hot water • scope detached house of approx 4-5 persons • hygienic water heating by the limited water content and the continuous-flow principle • for heating with solar for low-temperature heat generators heat pumps or hightem­pe­rature heat generators e.g biolyt agrolyt® ultragas® solar heating water storage • made of steel coated outside • 8 heating connections rp 1½″ • plain tube heat exchanger built in solar connection • solar flow and return r ¾″ for connection of solar armature group sag • corrugated pipe stainless steel heat exchan­ ger spiral built in • domestic water flow and return rp 1¼″ • 1 sleeve rp 1½″ for screw-in electrical heating inset • 2 sleeves ½″ for sensor/thermometer •

hoval ultrasol ultrasol eco â– â– part no roof connections for on-roof installation part no determining the number of roof connection sets see chapter engineering/table 1 and 2 subject to modifications 1.4.2016 roof bar set adjustable tile for attaching the carrier profiles for on-roof attachment of ultrasol consisting of 2 roof bars screw set us-shs 6037 731 roof bar set adjustable heavy duty for elevated static requirements for attaching the carrier profiles for on-roof attachment of ultrasol consisting of 2 roof bars hd screw set us-shs 6037 764 packing plate 2mm for levelling the roof bars 2061 367 packing plate 3mm for levelling the roof bars 2061 368 roof bar set plain tile for attaching the carrier profiles for on-roof attachment of ultrasol consisting of 2 roof bars screw set us-shs installation set t-head bolt 6037 767 roof bar set slate/flat eternit for attaching the carrier profiles for on-roof attachment of ultrasol consisting of 2 roof bars screw set

hoval ultrasol ultrasol eco ■■part no roof inlay mounting sheet-metal flashing provided by the customer installation sets in-roof installation sheet-metal flashing provided by the customer part no one over another vertical in-roof one over another vertical for hoval flat collectors ultrasol v ultrasol eco v for in-roof installation without sheet-metal flashing for fastening on tiled roof e.g interlocking tiles sliding tile plain tiles minimum roof pitch is determined by the sheet-metal flashing provided by the customer not allowed to be less than 20° leaktight subroof necessary comprising complete fitting accessories for attachment on cross battens hydraulic collector connections and connections 3-layer sealed elastic connection pipes 1 unit 90° elbow with immersion sleeve for collector sensor 1 unit 90° elbow connection pipe between upper and lower row dummy plug man air vent for number of collectors per collector field units subject to

hoval ultrasol ultrasol eco â– â– part no part no 32 expansion set in-roof bles 1vu set for in-roof mounting of one additional collector ultrasol v ultrasol eco v one above the other comprising:collector fastening rails fastening material spacer middle sheets including connector side sheets left and right 6031 635 basic set in-roof blgs 1h set for in-roof mounting of 1 collector ultrasol h ultrasol eco h comprising:collector fastening rails fastening material collector stop individual collector ridge sheet individual collector incl supports eaves sheet individual collector side sheets left and right 6031 636 basic set in-roof blgs 2hn set for in-roof mounting of 2 collectors ultrasol h ultrasol eco h adjacent to one another comprising:collector fastening rails fastening material collector stops for 2 collectors ridge sheets for 2 collectors incl supports eaves sheets for 2 collectors side sheets left and right intermediate sheet 6031 637 expansion set in-roof bles 1hn set

hoval ultrasol ultrasol eco ■■dimensions hoval ultrasol ultrasol eco vertical dimensions in mm 1 2 collector connection outlet ¾″ with hoval hydraulic connection brackets collector connection inlet ¾″ with hoval hydraulic connection brackets one-sided connection left or right possible not tichelmann connection on alternating sides possible tichelmann hoval ultrasol ultrasol eco horizontal dimensions in mm 1 2 collector connection outlet ¾″ with hoval hydraulic connection brackets collector connection inlet ¾″ with hoval hydraulic connection brackets one-sided connection left or right possible not tichelmann connection on alternating sides possible tichelmann 42 subject to modifications

hoval ultrasol ultrasol eco ■■examples recommended pipe dimension copper or stainless steel pipe for monopropylene glycol/water mixture 40/60 and 50 °c volume flow dn 10 12 x 1 mm dn 12 15 x 1 mm dn 15 18 x 1 mm [l h [l/min v ∆p [m/s [mbar/m v [m/s ∆p [mbar/m v [m/s dn 20 22 x 1 mm dn 25 28 x 1.5 mm dn 32 35 x 1.5 mm dn 40 42 x 1.5 mm ∆p v ∆p v ∆p v ∆p v ∆p [mbar/m [m/s [mbar/m [m/s [mbar/m [m/s [mbar/m [m/s [mbar/m 125 2.08 0.44 3.10 0.26 1.10 0.17 0.50 0.11 0.20 0.07 0.10 0.04 0.00 0.03 0.00 150 2.50 0.53 6.70 0.31 1.30 0.21 0.60 0.13 0.20 0.08 0.10 0.05 0.00 0.03 0.00 175 2.92 0.62 8.70 0.37 1.50 0.24 0.70 0.15 0.30 0.10 0.10 0.06 0.00 0.04 0.00 200 3.33 0.71 10.90 0.42 3.20 0.28 0.80 0.18 0.30 0.11 0.10 0.07 0.00 0.05 0.00 250 4.17 0.88 15.90 0.52 4.60 0.35 1.70 0.22 0.40 0.14 0.20 0.09 0.10 0.06 0.00 300 5.00 1.06 21.70 0.63 6.30 0.41 2.40 0.27 0.80 0.17 0.20 0.10 0.10 0.07 0.00 350 5.83 1.24 28.30 0.73 8.20 0.48 3.10

hoval solar armature groups ■■part no accessories chamber connection side chamber connection side subject to modifications 1.4.2016 part no console with strap-on band for reflex ng 8-25 s 8-25 v 6-20 vertical installation container connection upwards or downwards 242 878 quick connection su r¾″ x ¾″ for diaphragm-type expansion chambers in closed heating and cooling water plants with shut-off valve against unintended closing check ball and drain according to din 4751 part 2 tested by tÜv connection r ¾″ pn 10/120 °c 242 771 quick connection su r 1″ x 1″ for diaphragm-type expansion chambers in closed heating and cooling water plants with shut-off valve against unintended closing check ball and drain according to din 4751 part 2 tested by tÜv connection r 1″ pn10/120 °c 242 772

hoval solar heat transfer stations ■■technical data transtherm solar pump primary/secondary circuit voltage max power consumption primary/secondary circuit max current primary/secondary circuit max pressure primary/secondary circuit max temperature primary/secondary circuit max temperature temporary primary/secondary circuit v w a bar °c °c flow measuring range l/min 1 25 50 100 200 pm2 15-145 pm2 15-65 1x230 69/48 0.68/0.4 6/3 120/95 160/120 pm2 15-145 pm2 15-65 1x230 69/48 0.68/0.4 6/3 120/95 160/120 pml 25-145 upm2 25-75 1x230 140/70 1.18/0.52 6/3 120/95 160/120 upm xl 25-125 upml 25-105 1x230 180/140 1.4/1.1 6/6 120/95 160/120 0.5-15 1 0.5-15 1 1-35 1 5-100 1 optional accessories secondary circuit recommended balancing valve or flowrotor restförderhöhe solar-lademodul residual overpressure of the solar charging module transtherm solar 25 transtherm solar 25 h [kpa h [m 15 150 1 14 140 13 130 12 120 11 110 pm2 15-145 10 100 90 9 80 8 7 2 70 pm2 15-65 6

hoval toptronic® e solar module ■■part no toptronic® e solar module toptronic® e solar module tte-sol the controller module is suitable for use as temperature differential control control of thermal solar plants for heating process water and/or heating support controller module with integrated control functions for solar circuit collector cascade storage tank cascade with up to 4 consumers consumer loading with type selection temperature differential control loading and unloading function for additional/reserve buffer tank integrated solar yield calculation part no 6037 058 6034 503 consisting of toptronic® e solar module incl 2 pcs mounting clips for top hat rail attachment 1 pce immersion sensor tf/2p/5/6t l=5 m 1 pce collector sensor tf/1.1p/2.5s/5.5t l=2.5 m basic plug set for controller module mains in plug for 230 v output va3 plug for 2x 230v output va1/va2 plug for optocoupler input sk-va3 2x plugs for sensors

engineering of solar plants ■■engineering dimensioning guidelines valid for flat collectors under the following conditions 1 average sun exposure about 1200 kwh per square meters and year related to the horizontal irradiation surface and the central european climate conditions 2 sunshine on the collector surface more than 90 no shade 3 collector angle of inclination depending up­on type of use and period of use open-air swimming pool from may to september 25-35° service water and indoor swimming pool 30-50° service water all year round 35-55° service water and additional heating 40-60° 4 deviation of the collector surface from the south 35° in the case of deviations from 35 up to 45° of the south direction an en­ large­ment of the collector surface of approx 20 is necessary collector arrangements with deviations greater than 45° from the south direction are not recommended 5 as far as possible the entire collector surface should be

responsibility for energy and environment the hoval brand is internationally known as one of the leading suppliers of indoor climate control solutions more than 66 years of experience have given us the necessary capabilities and motivation to continuously develop exceptional solutions and technically advanced equipment maximising energy efficiency and thus protecting the environment are both our commitment and our incentive hoval has established itself as an expert provider of intelligent heating and ventilation systems that are exported to over 50 countries worldwide hoval aktiengesellschaft austrasse 70 fl-9490 vaduz principality of liechtenstein swiss customs territory phone +423 3992 400 fax +423 3992 618 e-mail info@hoval.com www.hoval.com hoval heating technology as an energy-neutral supplier with a full range of products hoval helps its customers to select innovative system solutions for a wide range of energy sources such as heat pumps biomass solar energy gas oil and district