colour rendering index cri the quality of light a measure of the ability of a light source to reproduce the colours of various objects a light source with a cri of 100 ra would be perfect and balanced in terms of colour reproduction shading and contrast lumen depreciation l70 the deterioration in a lights performance after a time lumen depreciation values reflect the overall performance of a light source through its life all light sources suffer from lumen depreciation which can be accelerated by poor thermal conditions over voltage or incorrect application l70 is the operating time hours until the led lumen output is depreciated to 70 of its initial lumens ip ratings a fittings protection against dust and moisture ingress protection ip is a value given to products that have particular protection against dust and/or moisture the ip number is split the first digit represents the level of protection against dust particles while the second digit represents the protection against moisture

lighting guides guide for the number of fittings needed for your room size skytile base ® the direct fluorescent replacement 5m 6m 7m 8m 9m 10m 5m 6 6 8 8 10 10 6m 6 8 8 9 12 12 7m 8 8 12 12 12 15 8m 8 9 12 12 16 16 9m 10 12 12 16 16 20 10m 10 12 15 16 16 20 notes 1 2 3 all of the above quantities are for guidance only based on office lighting level of circa 400 lux 2.4m ceiling throughout 4 5 6 0.8 maintenance factor reflectance of 70:50:20 length/width in metres fgled10 ® the high output fire rated led downlight 2m 2m 3m 4m 5m 6m 7m 8m 9m 10m 3m 2 4m 4 1 4 2 6 2 6 3 4 3 4 4 8 6 12 4 10 7 6 6 6 9 8 8 12 9 8 12 12 12 30 12 12 indicates approx number of 50w gu10 halogen fitting 16 16 16 16 16 42 20 49 20 20 49 20 42 16 16 36 42 42 36 16 16 16 16 12 36 36 36 36 36 12 12 12 12 30 30 30 30 30 9 12 12 8 25 25 25 30 25 25 25 9 25 25 20 16 9 8 8 9 20 6 16 20 25 9 20 25 20 16 12 6 6 5 9 20 20 12 10 6 16 6 6 8 20 12 16 20 6 20 5 6 16 10m 10 12 6 6 16 4 12 16 9m 10 4 4 6 8m 8 12 12 12 12

understanding bathroom zones iee wiring regulations bs 7671 2008 section 701 gives requirements for areas containing a bath or shower this document should be consulted before installation of appliances areas of the bathroom are split into zones as a guide only the requirements for luminaries in each zone may be summarised as follows particular care should also be taken with wash basins guidance for these are also contained within bs 7671 2 1 1 0 0 zone 0 refers to the interior of the bath or shower that can hold water requires electrical products to be low voltage max 12v and rated ipx7 254 technical zone 1 refers to the area above the bath or shower up to a height of 2.25 metres and requires a minimum rating of ipx4 splash-proof plus rcd protection ipx5 should be considered if water jets may be present i.e for cleaning purposes zone 2 covers an area 0.6 metres wide immediately next to and all around zone 1 wash basins should also be treated as zone 2 the minimum rating here is ipx4

emergency lighting what is an emergency light fitting emergency light fittings include a battery as a backup power source that is continuously charged emergency light fittings can tell when the power has failed and immediately switch to using the backup battery the battery needs to power the light fitting for a minimum of 3 hours to conserve power the light output from the fitting is reduced often to 10 of the normal light output what are the different types of emergency light fittings maintained fitting – will operate as a normal light fitting and be controlled with all the other lights in the area however when the power fails the maintained emergency fitting will continue to operate but at a lower light level non-maintained fitting – is normally switched off with its batteries being continuously charged and a green led showing fully charged when the power fails then the fitting switches on using its battery supply non-maintained fittings are not part of the general

3 daylight compensation harvesting the cheapest and best form of lighting is natural daylight lighting controls can be designed to adjust the light output from the light fittings when the amount of daylight in a room changes throughout the day and seasons optimum light level 100 90 level of artificial light required of required light 80 70 60 50 40 30 20 level of natural daylight 10 0 dawn 50 artificial light 50 natural daylight 65 artificial light 35 natural daylight noon dusk 4 constant illuminance light fittings lose some of their brightness over time measured as the time taken to lose 30 of the original light output l70 led lights generally have a much better l70 performance than traditional lighting if lighting controls are used then the area can be maintained at the correct level maintained level however if controls are not used then the options available are to  • initially over-light an area which will achieve the correct future lighting level or  • initially

communication protocols communications protocols are the method of transmitting information to the light fittings phase dimming uses the mains alternating current ac to reduce power to the light fitting by cutting out sections of the ac supply phase dimming was designed for traditional lighting technology and is common in lower power domestic lighting but is unsuitable for commercial applications due to the larger power requirements the supply can be cut from the front of the ac wave leading edge dimming and/or the back edge trailing edge dimming dimming 240v ac leading edge 240v input • separate control wire not required • for lower power applications 1-10 volt analogue uses a separate control wire to notify the driver that the power to the leds should be changed the separate control signal is a direct current dc and can be adjusted from 1 up to 10 volts the voltage level is interpreted by the driver to set the led power separate 1-10v control wire may need screened

index code section code section jc2007 downlights page 63 jc14112 track spotlight page 170 jc2009 downlights 63 jc14154 track spotlight 165 jc2033 downlights 62 jc14155 track spotlight 165 jc2034 downlights 62 jc14156 track spotlight 165 jc2107 downlights 61 jc14157 track spotlight 165 jc3014 undershelf cabinet 189 jc14158 track spotlight 177 jc4030 downlights 189 jc14159 track spotlight 177 jc5052 n downlights 50 jc14160 track spotlight 178 jc5054 downlights 50 jc14161 track spotlight 178 jc5060 downlights 50 jc14162 track spotlight 179 jc5092 downlights 57 jc14163 track spotlight 179 jc5110 downlights 50 jc14200 track spotlight 167 jc5118 downlights 50 jc14201 track spotlight 167 jc5133 downlights 57 jc14202 track spotlight 162 jc5133hf3m downlights 57 jc14203 track spotlight 162 jc5368 downlights 50 jc14204 track spotlight 167 jc5400 downlights 48 jc14205 track spotlight 167 jc5401 downlights 47 jc14206 track spotlight 162 jc5402 downlights 49 jc14207 track

index code section code section jc71276dh led panels 69 jc71353/1-10v led panels 71 jc71276dsi led panels 70 jc71353dali led panels 71 jc71276pd controls accessories 69 jc71353dsi led panels 71 jc71276pd controls accessories 242 jc71354 led panels 71 jc71276pd controls accessories 243 jc71354/1-10v led panels 71 jc71277 led panels 71 jc71354dali led panels 71 jc71277/1-10v led panels 71 jc71354dsi led panels 71 jc71277dali led panels 71 jc71355 led panels 70 jc71277dsi led panels 71 jc71355/1-10v led panels 70 jc71278 led panels 70 jc71355dali led panels 70 jc71278/1-10v led panels 70 jc71355dh led panels 69 jc71278dali led panels 70 jc71355dsi led panels 70 jc71278dh led panels 69 jc71355pd led panels 69 jc71278dsi led panels 70 jc71356 led panels 70 jc71278pd led panels 69 jc71356/1-10v led panels 70 jc71279 led panels 71 jc71356dali led panels 70 jc71279/1-10v led panels 71 jc71356dh led panels 69 jc71279dali led panels 71 jc71356dsi led panels 70 jc71279dsi led panels 71

notes +44 01243 838999 technical

notes +44 01243 838999 technical

export tel +4401243 838994 fax +4401243 838982 email exports@jcc.co.uk account managers key account manager dan golding tel 07803 237307 nationwide account managers 1 danielle tuck tel 07717 894248 south west 2 ellie noble tel 07790 926689 midlands north 3 2 3 1 yazmin hills tel 07551 158489 london south east anglia project managers head of uk specification noel cox tel 07825 065605 nationwide led project managers 3 1 annelise roberts tel 07867 455259 central 2 anthony mccreadie tel 07790 926650 south 3 lucy wilson tel 07880 194396 north 1 2 national accounts tel 07703