Catalog Radiation protection 2017

radiation protection in diagnostic radiology hss drills junction box cover free pdf file 9 mm cutter wall edging strips edging strip drill hss 4 gang boxes hm 80 box cutters kv 150 thick walled tube 6 mm through wall tube fitting

Radiation protection 2017 is listed under these categories

Industrial Supply > Electrical & Test

Featured catalog pages of Radiation protection 2017

radiation protection electrical installation in radiation protection

for screened x-ray rooms radiation protection technology radiation protection in connection with electrical installation in radiation protection walls presents a real challenge secure radiation protection must be ensured by means of special building construction measures in particular this affects hospitals doctors practices and all medical facilities in which x-rays and gamma radiation equipment are used the ionising radiation which is emitted by the x-ray devices is extremely hazardous for people in the vicinity this means that adjacent rooms must be screened every installation opening in radiation protection walls interrupts the wall s radiation protection function elaborate screening methods are needed in order to restore this function 2 www.kaiser-elektro.de in many cases screening is fitted in the form of lead encasing around traditional electrical installation boxes the planning of the necessary electrical installation in these walls is a major problem it is extremely

radiation protection brandschutz basics regulations and standards röv and din 6812 national and international laws and decrees have been passed and standards specified in order to protect people who are constantly or occasionally exposed to x-rays against the dangers from ionising radiation in germany these include the radiation protection act strlschv and the x-ray ordinance röv the latter describes the ordinance relating to protection against harm caused by x-rays and this also applies to diagnostic radiology and radiation protection therapy radiation protection in buildings is regulated in din 6812 for medical x-ray equipment up to 300 kv in general a distinction is made in respect of the type of radiation between useful radiation and stray radiation useful radiation occurs in the direction specified for that purpose in the x-ray device stray radiation displays a scattering effect and occurs in different directions and strengths technical basics radiation protection walls

lead-free safety for x-ray rooms one-gang junction box for radiation protection walls kaiser s innovative radiation protection box protects against radiation used for medical purposes e.g in x-ray facilities the high density of the radiation protection compound absorbs soft and hard x-rays the box is especially suitable for lead-free radiation protection walls e.g knauf safeboard and because of its dose-reducing effect in the tube voltage range between 40 150 kv guarantees a lead-equivalent value for the wall up to 3 mm pb even with opposing installation • • • • • • protection against x-rays suitable for lead-free radiation protection walls lead-free no health risks retrofitting is possible fast installation without additional screening measures opposing installation is possible the radiation protection box is very easily fitted in a Ø 74 mm installation opening in the same way as a traditional cavity wall box use the universal opening cutter

radiation protection lead-free radiation protection 2 1 the wall’s radiation protection is maintained even when installation boxes are fitted 3 1 multiple combinations are possible without any negative effects on the radiation protection 2 use a cutter e.g multi 4000 1084-10 to cut the installation opening 3 exact opening by using universal opening cutter radiation protection one-gang junction box art no 9074-01 support connector art no 9060-74

lead-lined safety for x-ray rooms one-gang junction box for radiation protection walls the kaiser radiation protection box for use in lead-lined walls protects against x-rays used for medical purposes e.g in x-ray facilities the radiation protection material with its integrated lead function component absorbs the dangerous x-rays with a lead equivalent of 2.5 mm pb just as effectively as 2.5 mm thick lead the wall’s radiation protection is completely maintained even when installation boxes are fitted • • • • • protection against x-rays suitable for lead-lined radiation protection walls no risk to health no skin contact with lead function component retrofitting is possible fast installation without additional screening measures proof of radiation protection the german tuv-nord ensys has demonstrated that in the range of tube voltages between 90 and 150 kv kaiser’s radiation protection box with the lead function component achieves a lead

radiation protection lead-lined radiation protection 2 1 3 1 the wall’s radiation protection is maintained even when installation boxes are fitted 2 the fully-insulated through-wiring takes place with the support connector 3 up to a 5-way combination of boxes is possible without negative effects on the radiation protection radiation protection one-gang junction box lead-lined art no 9074-03 support connector art no 9060-88

a b 2 1 2 d c 2 1 e 1 1 2 1 1 f 1 1 2 3 wall constructions for lead-free and lead-lined radiation protection panels the following describes different wall constructions in connection with the required number of lead-free and lead-lined radiation protection panels and a plasterboard panel in accordance with the lead equivalents specified in din 6812 details of the relevant lead equivalent are shown in the table below with the matching illustration lead equivalent value in mm pb illustration 0.3 0.6 a 1.0 1.1 b ≤ 1.75 c ≤ 2.75 d ≤ 3.0 e ≤ 2.5 f use in lead-free radiation protection walls e.g knauf safeboard a lead equivalent up to 0.6 mm pb wall construction 2 layers of boarding on both sides b lead equivalent up to 1.1 mm pb wall construction 2 layers of boarding on both sides c lead equivalent up to 1.75 mm pb wall construction 2 layers of boarding on both sides d lead equivalent up to 2.75 mm pb wall construction 2 layers ofboarding on both sides e two

installation radiation protection walls 1 2 3 4 fast installation of the one-gang junction box for radiation protection walls installation 1 use a cutter e.g multi 4000 or multi 2000 hm to cut a Ø 74 mm installation opening 2 use an hss drill to prepare for the matching cable entry 3 use the universal opening cutter art no 1085-80 to make the cable entry match the specified cable retention 4 feed the cables in then insert the box into the installation opening turbo cutter multi 4000 art no 1084-10 universal opening cutter art no 1085-80 for extending existing installation openings from Ø 68 mm to Ø 74 mm exact guide for cavity wall cutter multi 4000 multi 2000 hm art no 1084-70 centering insert 68/74 art no 1083-99

Ø 74 mm Ø 68 mm Ø 68 mm Ø 74 mm 2 Ø 74 mm 1 3 4 1 remove the traditional box from the Ø 68 mm installation opening 2 insert the centering insert 68/74 art no 1083-99 together with the Ø 74 mm cutter e.g multi 4000 art no 1084-10 or multi 2000 hm art no 1084-70 into the existing opening 3 now it is easy to enlarge the existing opening Ø 68 mm to Ø 74 mm 4 the radiation protection box can now be retrofitted in the Ø 74 mm installation opening refurbishing centering insert 68/74 for retrofitting the centering insert 68/74 makes it easy to enlarge existing installation openings from Ø 68 mm to Ø 74 mm this can be with lightweight walls with single or multiple-layer boarding consisting of lead-free radiation protection panels e.g knauf safeboard and of lead-lined plasterboard panels this makes it much easier to replace existing traditional cavity wall boxes with radiation protection boxes the centering insert 68/74 mm is an easy-to-use tool aid for Ø

brandschutz radiation protection product overview assignment table for cutting an opening for the radiation protection one-gang junction box universal opening cutter 1085-80 hss drill cavity wall installation for radiation protection boxes 9074-01 lead-free nym cables support connector universal opening cutter Ø 3 x 1.5 mm2 9.5 mm 5 x 1.5 mm2 9.5 mm 3 x 2.5 mm 10.5 mm 2 cut up to the marking of the connector entry 9060-74 cavity wall installation forradiation protection boxes 9074-03 lead-lined nym cables hss drill Ø universal opening cutter Ø 3 x 1.5 mm2 8.0 mm 9.5 mm 5 x 1.5 mm 2 9.5 mm 9.5 mm 3 x 2.5 mm2 9.5 mm 9.5 mm 5 x 2.5 mm support connector 2 9060-88 9.5 mm connector 12 mm cut up to the marking of the connector entry kaiser radiation protection system at a glance www.kaiser-elektro.org/strahlenschutz installation in walls radiation protection boxes radiation protection radiation protection box box lead-lined 9074-01 p 4 9074-03 p 6 support connector 9060-74

systems and solutions for professional electrical installation since 1904 kaiser has been developing systems and products as a basis for good installation planners and processors use the practical solutions internationally for their daily tasks in all sectors of installation work energy efficiency iinnovative kaiser products support you in satisfying the requirements of eu directives and national ordinances such as germany’s energy-saving ordinance enev fire-protection kaiser fire protection systems offer you reliable solutions for electrical installations in fire protection walls and ceilings sound insulation walls the use of the new radiation protection boxes maintains the wall’s radiation protection without additional screening measures refurbishing kaiser has matching product system solutions which can solve these problems safely consistently and in accordance with building-site practices during refurbishing renovation and modernising work technical information and