Catalog: Digital Indicators
Company/Brand: Lesman Instrument Company
|
| | 38 controllers and programmers digital indicators ... 2007 lesmaninstrumentcompany www.lesman.com sales@lesman.com wisconsin and upper ... panel meter that handles all the common process display applications with ... if you want to program the trident s copy function allows one meter s setup to be ... automatically copied to another meter the trident can be ... used for data acquisition with a pc by connecting an optional serial communication ... from a pc the trident s shallow-depth case is designed for easy installation and ... plenty of overlap even for rough hand-cut panel cutouts the mounting brackets ... in the panel removable screw terminal connectors allow easy and convenient wiring one ...
|
| | process/rtd 3.7 to 5/sec t/c 1.8 to 2.5/sec programmingmethods four ... buttons pc and meterview software or cloning using copy function noisefilter ... 2 to 199 to disable filter program 0 re-calibration all ranges are calibrated at the ... factory re-calibration is recommended at least every 12 months ... 32° to 149°f 0° to 65°c relativehumidity 0 to 90 noncondensing ... connections removable terminal blocks accept 12 to ... gasket provided mounting 1/8 din panel cutout required two panel mounting brackets ... warranty 3 years parts and labor can be extended 12 months by returning the ... product registration form within 2 months from date of purchase ... approvals ce ul and cul pending temperature meter inputs field ...
|
| | automatic lead zero blanking totalizer calculates total based on time factor of seconds ... when display exceeds 999.999 peakhold captures peak rate and displays it via the front ... panel flashing r led lowflowcutoff 1 count to 100 fs user-selectable to disable ... low flow cutoff program value to 0 enclosure 1/8 din ... nema 4x,type 4x panel gasket provided connections removable screw terminal block power ... relayrating 2 or 4 relays 2 amp spdt form c 2 amp 30 vdc or 2 amp 250 vac ... wave 0-5v or 0-12v 30 khz ttl open collector 4.7 k pull-up to 12 v 30 khz switch ... contact 4.7 k pull-up to 12v 40 hz calibration via internal calibration i-cal or ... external signal e-cal outputpower field selectable isolated ...
|
| | 44 controllers and programmers digital indicators ... 2007 lesmaninstrumentcompany www.lesman.com sales@lesman.com wisconsin and upper ... or rtd · 4 alarms standard · no calibration necessary · nema 4x type 4x front panel ... red 4 1/2 digit led plus f or c coldjunctionreference automatic fixed no calibration ... necessary tcopenindicator open t/c circuit indicated by flashing display relay ... by setting alarm points 4 any combination high or low status indicator front ... abs plastic nema 4x type 4x front panel connections removable screw terminal block accepts ... -readable led display · rs485 serial communications modbus® rtu option · data acquisition ... software · 4-20 ma analog output · two form c 3-amp relay options model selection ...
|
| | 46 controllers and programmers digital indicators ... pressure transmitters multichannel controllers illinois indiana iowa and sw michigan ... 2007 lesmaninstrumentcompany www.lesman.com sales@lesman.com wisconsin and upper ... -1700 · 262-923-1790 fax 262-923-1797 consolidator®multichannel controllers great for tank levels ... inputs · rs232 modbus® rtu · nine form c 10-amp relays · easy to read backlit ... lcd · low flow cutoff · 32-point linearization · square root ... panel keys · panel and wall-mount units consolidator® screen features · relay status on/off ... hours of operation number of cycles · control relay operation reset hours and cycles ... · analog and pulse inputs alarm and control relays · tank or well level monitoring ...
|
| | applications · filling systems · clean room pressure monitoring · hepa filter ... monitoring and alarms · coating and painting booths fume hoods · hvac ... systems features n perfect for clea · 0.2 wc to 50 wc and compound ranges ... easy panel mounting essure hood pr easy cal includes compact din enclosure · ... high and low alarm states · isolated form a contacts · high and low limit monitor ... save time and m with easy caltmoney · 4-20 ma analog output standard 0-10 ... vdc output optional place calibration in· removable terminal block for 18-26 ... awg wire certification toand · 12-24 vac/vdc power 21 cfr 11 ... · solid state sensors · analog circuit design eliminates potential ... problems ordering instructions · compliant to ul 508 and ce en 61326 emi ...
|