High Vacuum Pumps 2017 by Leybold

More catalogs by Leybold | High Vacuum Pumps 2017 | 200 pages | 2017-05-08

Ads

Page 134 of High Vacuum Pumps 2017

technical data high vacuum forevacuum connection dn pumping speed for air below 1 x 10-4 mbar dip 3 000 dip 8 000 dip 12 000 250 iso-k 63 iso-k 400 iso-k 63 iso-k 500 iso-k 100 iso-k 3 000 8 000 12 000 1 l x s-1 mbar 10 to 10 torr 0.75 x 10-2 to 0.75 x 10-7 operating range mbar torr ultimate total pressure 1 max permissible forevacuum pressure mbar torr l qts pump fluid filling min max mains connection standard euro 50/60 hz standard americas 50/60 hz special 50/60 hz v v v 10-2 to 10-7 0.75 x 10-2 to 0.75 x 10-7 5.0 x 10-7 3.75 x 10-7 5.0 x 10-7 3.75 x 10-7 5.0 x 10-7 3.75 x 10-7 6.0 x 10-2 4.5 x 10-2 6.0 x 10-2 4.5 x 10-2 6.0 x 10-2 4.5 x 10-2 1.0 1.4 1.1 1.5 1.7 3.4 1.8 3.6 2.4 5.3 2.5 5.6 230 1 ph 230 1 ph – 400 3 ph y 460 3 ph y 230 3 ph Δ 400 3 ph y 460 3 ph y 230 3 ph Δ -7 -2 -7 kw 2.4 4.8 7.2 heating power 2 6 9 number of heating cartridges min heating up time cooling water minimum for pump 2 for cold cap baffle max supply pressure 10 to 10 0.75 x 10-2 to 0.75 x 10-7 -2 l x h-1 gal/min l x h-1 gal/min bar psig number of cooling circuits including cold cap baffle 25 25 25 160 0.7 20 0.09 6 87 290 1.28 30 0.13 6 87 500 2.2 50 0.22 6 87 2 2 2 cooling water connection for pump for cold cap baffle g bps 3/8 1/2 1/2 g bps 1/4 3/8 3/8 weight approx kg lbs 70 154 102 225 sv 300 w 251 sv 300 w 501 – trivac d 65 b w 251 trivac d 65 b w 251 dip 3 000 dip 8 000 dip 12 000 part no part no part no oil diffusion pump standard euro standard americas special 222 10 222 10 – 222 20 500 670 500 649 222 25 500 591 22225v003 astrotorus baffle 227 50 227 60 227 65 water flow monitor over-temperature protection switch 122 84 122 84 122 84 contact thermometer 218 81 218 81 218 81 resistance thermometer pt100 sensor 200 02 958 200 02 958 200 02 958 pump fluid recommended backing pump 3 at operating pressures 10-4 mbar 0.75 x 10-4 torr at operating pressures 10-4 mbar 0.75 x 10-4 torr trivac d 65 b w 251 ordering information 3 4 1 2 4 29 64 500006623 500006623 500006623 see catalog part “oils greases lubricants leybonol” measured to din 28 427 with leybonol lvo 500 as the pump fluid the required quantity of cooling water refers to Δt 10 °c 50 °f the discharge temperature should not exceed 30 °c 86 °f single or two-stage rotary vane vacuum pump trivac sogevac from our range of forevacuum pumps jointly with roots vacuum pumps ruvac in pump systems oil must be purchased separately 134 leybold full line catalog fall 2016 leybold