Catalog: VNA Calibration Kits, Microwave Components & Adapters Catalog
Company/Brand: Maury Microwave
8 in lb torque wrench in VNA Calibration Kits, Microwave Components & Adapters Catalog by Maury Microwave
microwave components adapters model index model 2440b 2440c 2450 series 2453a ... 2518a 2553k 2553t3 2553t3.12 2553t3.82 2553t5 2553t6 2553t7.5 2553t10 2553t15 ... 2561e page 14mm slide screw tuner 0.8 8.0 ghz 142 ... line 30.0cm 38 85 14mm beadless air line ... 85 14mm beadless air line ... 85 14mm beadless air line ... 85 14mm beadless air line ... 85 14mm beadless air line ... 85 14mm beadless air line ... 85 14mm beadless air line ... 85 14mm beadless air line kit ...
microwave components adapters model index model page model 2697a 2697s5 2698c2 ... 20 3/4-inch hex torque wrench 12 in lbs 20-24 26-27 94 139 9/16-inch ... hex torque wrench 12 in lbs 28-30 32 94 9/16-inch ... hex torque wrench 8 in lbs 36 94 1-1/16-inch ... hex torque wrench 20 in lbs 40 42-43 94 13/16-inch hex ... torque wrench 12 in lbs 94 7-16 female to ... air line 42 85 7-16 female to male beadless air line ... 42 85 7-16 female to male beadless air line ... 42 85 7-16 female to male beadless air line ...

microwave components adapters model index model 8778a2.00 8778b1.10 8778b1.15 ... 8778b1.20 8778b1.25 8778b1.30 8778b1.50 8778b1.75 8778b2.00 8779a1 8779b1 8780a series ... 8780b series 8780f series 8780m series 8781a 8781b 8782a 8782b 8783a 8783b 8784e ... 8787g 8787h 8787j 8787k 8787q 8787r 8787s 8787t 8799a1 8799d1 8799e1 8800 8801a ... 8801b 8801c 8801k 8801l 8803a 8803b 8803c 8803d 8806a 8806b 8806c 8806d 8806g ... 8807a 8807b 8807c 8807d 8809b1 8810b1 8816a page model 2.92mm k female precision ...

precision vna calibration kits 1.85mm vna calibration kits 7850a standard ... kits features 1.85mm connectors dc to 67 ghz operates dc to ... description these precision 1.85mm connector calibration kits are designed ... measurements of devices equipped with 1.85mm connectors from dc to 67 ghz each kit ... includes a full complement of calibration ... vna software and a set of adapters are included all kit components come housed in an ... attractive foam-lined wood instrument case 7850a components included in 7850a ... 1 1 1 1 1 1 1 1 1 1 1 1 1 description 1.85mm female fixed offset short 0.5cm 1.85mm ... female fixed offset short 0.606cm 1.85mm female fixed offset short 0.683cm 1. ... 85mm female fixed offset short 0.794cm 1. ... 85mm male fixed offset short 0.5cm 1.85mm male fixed offset short 0.606cm 1.85mm ...

precision vna calibration kits 1.85mm vna calibration kits 7850b/f/m fixed ... termination kits features 1.85mm connectors dc to 67 ghz operates dc to ... description these precision 1.85mm connector calibration kits are designed ... measurements of devices equipped with 1.85mm connectors from dc to 67 ghz each kit ... includes a full complement of calibration ... vna software and a set of adapters are included all kit components come housed in an ... attractive foam-lined wood instrument case 7850b components included in 7850b ... kits quantity description model 1 1.85mm female fixed offset short 0.5cm 7846a 1 ... 1.85mm male fixed offset short 0.5cm 7847a 1 ... 1.85mm female open 7848a 1 1.85mm male open 7848b 1 1.85mm female low ...

precision vna calibration kits 1.85mm trl/lrl vna calibration kits 7860a ... series features 1.85mm connectors trl/lrl calibrations dc to ... vnas description these precision 1.85mm calibration kits are designed for use ... network analyzers vnas the components in the kits are configured for use in ... measurements of devices supplied with 1.85mm connectors from dc to 67 ghz each kit ... includes a full complement of calibration ... vna software and a set of adapters are included all kit components come housed in an ... attractive foam-lined wood instrument case 7860a components included in 7860a ... 1 1 1 1 1 1 1 1 1 1 1 1 1 description 1.85mm female to male air line 0.96cm 1.85mm ... female to male air line 1.15cm 1.85mm female to male air line 3.00cm 1.85mm ...

network analyzers vnas the components in the kits are configured for use in ... connectors from dc to 50 ghz each kit includes a full complement of calibration ... all kit components come housed in an attractive foam-lined wood ... instrument case 7950a components included in 7950a kits quantity 1 1 1 1 1 1 1 1 ... 2.4mm male sliding termination torque wrench 8 in lbs 5/16-inch double end wrench 7/ ... 16-inch double end wrench vna software disk operating ... instructions manual instrument case model 7946a 7946b 7948a 7948b ... 7931a1 7931b1 7935a 7935b 8799a1 connector description the ... 2.4mm connectors are miniature instrument grade air-interface connectors that ... 287 general precision connector instrument grade gpc2.4 for interface ...

connectors from dc to 50 ghz each kit includes a full complement of calibration ... vna software and a set of adapters are included all kit components come housed in an ... attractive foam-lined wood instrument case 7950b components included in 7950b ... 2.4mm male fixed termination torque wrench 8 in lbs 5/16-inch double end wrench 7/ ... 16-inch double end wrench vna software disk operating ... instructions manual instrument case model 7946a 7946b 7948a 7948b ... 7931a1 7931b1 8799a1 connector description the ... 2.4mm connectors on the components in this kit are miniature instrument grade ... air-interface connectors that operate mode free up to ... 287 general precision connector instrument grade gpc2.4 for interface ...

from dc to 50.0 ghz components included in 7960a kits quantity 1 1 1 1 1 1 1 1 ... 2.4mm male fixed termination 5/16-inch double end wrenches vna software disk ... operating instructions manual instrument case model 7943s1.25 7943s1.50 7943s6. ... 1.50cm air lines note each kit also includes a set of adapters that is user ... gage kit thread-on type see page 92 8799a1 torque wrench 5/16-inch 8 in lbs see ... end of the kit model number as shown in the diagram at right the first digit ... the vna software option number as found in the option finder below the example in ... for use with an agilent pna that has 1.85mm or 2.4mm test ports vna softwar 7960a 1 ... zv series option 1 01 11 21 31 1.85mm or 2.4mm 1 2.92mm or 3.5mm 1 vna ...

kits 2.92mm k vna calibration kits 8770c standard kits features 2.92mm k ... k devices from dc to 40 ghz each kit includes a full complement of calibration ... all kit components are housed in an attractive foam-lined wood ... instrument case each kit is tested for 100 ... with a performance verification report 8770c components included in 8770c kits ... 2.92mm k male sliding termination 5/16-inch torque wrench 8 in lbs 5/16-inch double ... end wrench 7/16-inch double end wrench vna software disk operating ... instructions manual instrument case model 8771f1 8772f1 8773a1 8773b1 ... 8775a2 8775b2 8777a1 8777b1 8799a1 specifications for 8770c ...

kits 2.92mm k vna calibration kits 8770d fixed termination kits features 2.92mm ... k connectors from dc to 40 ghz each kit includes a full complement of calibration ... combinations all kit components including the vna software and operating ... instructions are housed in an attractive foam-lined wood ... instrument case 8770d04 components included in 8770d kits quantity 1 1 1 1 1 1 2 1 ... 2.92mm k male fixed termination 5/16-inch double end wrenches vna software disk ... operating instructions manual instrument case model 8771f1 8772f1 8773a1 8773b1 ... 8775a2 8775b2 2.92mm k connector description ... precision miniature 2.92mm air line interface connectors operate mode free to 40 ghz ...

2.92mm k trl/lrl vna calibration kits 8760a series tri-kits features trl/lrl ... 2.92mm k connectors from dc to 40 ghz 8760a components included in 8760a kits ... 2.92mm k male fixed termination 5/16-inch double end wrenches vna software disk ... operating instructions manual instrument case model 8774c15 8774c5 8774c6 8774c5 ... .25 8771f1 8772f1 8773a1 8773b1 8775a2 8775b2 trm/trl/lrl calibration maury ... to 40 ghz frequency range dc 160 800 mhz 2.5 ghz 12.5 ghz 800 mhz 800 ... 5.25cm air lines note each kit also includes a set of adapters that is user ... gage kit thread-on type see page 92 8799a1 torque wrench 5/16-inch 8 in lbs see ...

kits 3.5mm vna calibration kits 8050a standard kits 8050y expanded kits ... improved opens sliding load calibration in-series phase matched adapters are available ... description the 8050a standard and the 8050y expanded kits are 3.5mm calibration ... with 3.5mm 2.92mm k 2.4mm,or 1.85mm test set connectors and cables with ... connectors from dc to 34.0 ghz each kit includes a full complement of calibration ... the vna software and operating instructions come housed in an attractive foam-lined ... wood instrument case the expanded kits also include ... pin location prior to connecting these instruments and a torque wrench for accurate ... tightening of connector junctions 8050y17 components included in 8050a y kits ...

kits 3.5mm vna calibration kits 8050b fixed termination kits features 3.5mm ... dc to 26.5 ghz broad vna coverage in-series phase matched adapters are available ... connectors from dc to 26.5 ghz each kit includes a full complement of fixed load ... combinations all kit components including the vna software and operating ... instructions are housed in an attractive foam-lined wood ... instrument case 8050b07 components included in 8050b kits quantity 1 1 1 1 1 1 1 1 ... termination vna software disk operating instructions manual instrument case model 8046f ... 8047f 8048a1 8048b1 8031a5 8031b5 connector description 3.5mm ... connectors are air interface connectors that are fully compliant ...

kits 3.5mm trl/lrl vna calibration kits 8060a tri-kits features trl/lrl calibrations ... a range of agilent vnas the components in the kits are configured for use in ... 3.5mm male fixed termination 5/16-inch double end wrenches vna software disk ... operating instructions manual instrument case 8060a components included in 8060a ... kits model 8043s15 8043s5 8043s6 8043s5.3 8046f 8047f 8048a1 8048b1 8031a5 8031b5 ... to 34 ghz frequency range dc 160 800 mhz 2.5 ghz 12.5 ghz 800 mhz 800 ... 5cm 5.3cm air lines note each kit also includes a set of adapters that is user ... gage kit thread-on type see page 92 8799a1 torque wrench 5/16-inch 8 in lbs see ...

gated measurements 2660b24 components included in 2660b kits quantity 1 1 1 1 1 1 1 1 ... termination vna software disk operating instructions manual instrument case model 2653s3.12 ... 7mm quantity 2 1 1 2 1 1 model 2633c 8022a2 8022b2 7909c 7922a 7922b note each kit ... also includes a set of adapters that is user ... recommended accessories a028 a028d 8799a1 2698c2 connector gage kit push-on type ... gage kit thread-on type see page 92 torque wrench 5/16-inch 8 in lbs see page 94 ... torque wrench 3/4-inch 12 in lbs see page 94 vna softwar specification ... end of the kit model number as shown in the diagram at right the first digit ... the vna software option number as found in the option finder below the example in ...

kits osptm vna calibration kits 8780a standard kits 8780b fixed termination ... calibration kits are designed for use in calibrating vector network analyzers ... the positive coupling system featured in these connectors permits standards to ... be mated using a calibrated torque wrench this provides precise repeatability of ... each calibration interface and significantly improves accuracy ... compared to non-captivated blind-mate interfaces the 8780a standard kits include fixed ... shorts opens fixed and sliding loads a torque wrench an open-end wrench and a 3-1/2 ... inch data disk that provides the vna ... software for your specific vna the 8780b fixed termination kits have the same ... lack the sliding loads each kit comes in a foam-lined wood instrument case with ...

load calibration mpc14 gr900 connectors includes connector gage kit includes test port ... adapters dc to 8.5 ghz description these calibration kits ... and cables which will be used in making error-corrected measurements of ... devices with 14mm connectors from dc to 8.5 ghz each kit includes a full complement ... shorts opens sliding and fixed loads torque wrench connector gages 3.5mm to 14mm ... adapters and a 14mm contact installation/extraction tool with spare contacts ... needed to easily load the vna software into your vna is also included 2450f14 ... components included in 2450 kits quantity 1 1 1 2 1 1 1 1 1 1 ... 14mm connector gage kit push-on type 1-inch hex torque wrench 12 in lbs contact ... installation/extraction tool 14mm contacts spare ...

n tnc and bnc connectors rugged plastic instrument case dc to 26.5 ghz 1 description this ... vector network analyzers and are housed in rugged molded plastic cases the ... increased durability of the cases makes these ... service use the vna software provided in the operating instructions manual can ... be keyed in from the front panel of the analyzer ... the kits are available in female/male dual-sex configurations or ... in single-sex female or male ... configurations 8550q02 8550q03 components included in economy kits ... termination male fixed termination instrument case available kits select the ... female and male 3.5mm type n bnc tnc 8050q01 8850q01 8550q01 8650q01 8050q02 8850q02 ... 8550q02 8650q02 8050q03 8850q03 8550q03 8650q03 included in female single-sex ...

rated dc to 7.5 ghz usable to 8 ghz fixed load calibration low torque ... data disk supplied with the operating instructions manual in a foam-lined wood instrument ... 7-16 connectors found on the components in these kits are rugged calibration grade ... eliminate the need to apply excessive torque during calibration and test and tighter ... tolerance control than called for in the iec and bsen specifications to ... reduce uncertainties for interface specifications on these connectors ... to maury data sheet 5e-066 components included in 2750b kits quantity 1 1 1 1 1 1 1 1 ... 7-16 male fixed termination 1-1/16 inch torque wrench 20 in lbs 15/16 inch open ... -end wrench operating instructions manual instrument case model 2714a ...

-load-thru rated to 7.5 ghz usable to 8 ghz gated air line trl/lrl calibrations ... low torque coupling description these kits feature ... both female and male standards a torque wrench and an open-end wrench for ... listed at the right shipped together in a foam-lined wood instrument case see ... page 85 for air line specifications 2760b14 ... components included in 2760b kits quantity 1 1 1 1 1 1 1 1 1 1 ... 7-16 male fixed termination 1-1/16-inch torque wrench 12 in lbs 15/15-inch open ... end wrench operating instructions manual instrument case model 2735a6 ... 7-16 connectors found on the components in these kits are rugged calibration grade ... eliminate the need to apply excessive torque during calibration and test and tighter ...

calibration kit adapter options 7-16 in-series and 3.5mm 7mm and type n between-series ... 16 between-series adapters 7-16 to 7-16 in-series adapters phase matched within each ... series dc to 7.5 ghz usable to 8 ghz description the precision 7-16 ... adapters in these sets feature low vswr low ... insertion loss and are of minimum length test ... all of these adapters may be ordered in separately boxed sets as described ... with maury vna calibration kits or as individual adapters by model number adapter ... specifications the precision in-series and between-series adapters in these ... the same electrical length making them interchangeable for measurement of non-insertable ... each model is as follows precision 7-16 in-series adapters models 2712a/b/c for more ... 7-16 connector gage kit push-on type torque wrench see page 94 2698k1 7-16 1-1/16 ...

microwave components torque wrenches all models description maury s torque ... wrenches are recommended for tightening coaxial ... connectors in order to obtain optimum repeatability ... design so it is impossible to over-torque a coupled junction and torque can be ... applied in either direction each maury torque wrench is factory preset to the proper ... in lbs for tightening its coaxial connector ... make it easy to select the correct wrench from your toolbox at a glance maury ... torque wrenches are included in many of our vna calibration kits and ... separately by the model numbers listed in the chart below if the wrench you need ... isn t shown in this chart please contact our sales ... note the models shown are delivered in a non-calibrated state unless ...

lpc/osptm between-series adapters 8787 series description the lpc/osptm 1 ... to provide a precisely repeatable mated interface for calibration purposes and for test ... osptm 2 series blind-mate connectors interface dimensions of the connectors are ... the male connector allows torquing to 8 in/lb with a calibrated torque wrench ... 3 blind-mate connectors most adapters in the same series are phase matched and ... may be interchanged for vna measurement of non-insertable ... devices 8787r 8787t 8787g 8787h 3.5mm connector description the maury ... on these adapters are miniature instrument grade air-interface connectors that are ... they comply with ieee standard 287 for instrument grade general precision connectors gpc3 ...