711 Liquino, 700 Dosino, 718 Synthesis Controller by Metrohm AG

Catalogue: Metrohm AG 711 Liquino, 700 Dosino, 718 Synthesis Controller
Catalog: 711 Liquino, 700 Dosino, 718 Synthesis Controller
Company/Brand: Metrohm AG

Flippable HTML catalog

PDF catalog

Flippable Flash catalog

Visitor statistics

Metrohm AG Contact Information

Metrohm AG
Oberdorfstr. 68
CH-9100 Herisau

Phone +41 71 353 85 85
Fax +41 71 353 89 01

http://www.metrohm.com/

info@metrohm.com

Searched and found

02 m ptfe 10 ml 10 pin mini din plug 2 pin connector 2 pin connector din 25 pin cable 25 pin connector 28 mm 32 mm 500 mm length 6 cylinder 250 6 pin connector 6 pin connector din 6 pin din connector 6 pin mini din plug 6 pin to 9 pin db9 718 titrino 8 pin connectors 8 pin din connector 8 pin mini din 8 pin mini din plug 9 pin 9 pin connector 9 pin din ag 04 balance and control be 700 cable for printer connection cable din connector dosino exchange unit glass cylinder i 700 metrohm metrohm ag 9101 herisau metrohm pin connector metrohm titrino metrohm titrino 718 stat ph stat pt 100 reagents remote control remote controller remote controls shaft diameter 20 mm synthesis temperature sensor temperature sensor connector temperature sensors thread adapter 5 32 thread adapters upper and lower limits use 2 cable v 10

Similar catalogs to 711 Liquino, 700 Dosino, 718 Synthesis Controller

711 Liquino, 700 Dosino, 718 Synthesis Controller is listed here

Selected page of 711 Liquino, 700 Dosino, 718 Synthesis Controller

forget dropping funnels electronics and wet section clearly separated relief for encumbered fume cupboards the dosino sits on top of the reagent bottle and therefore requires very little space keypad and electronics are separated from the wet chemistry you monitor the reaction from your desk the dosing programs that can be performed may be grouped as follows dispensing functions in the xdos mode the new dosing experience the «electronic dropping funnel» doses a fixed volume with temperature monitoring if required in a given time interval e.g 3500 ml in 500 min the liquino calculates and displays the dosing rate and automatically takes into account the cylinder volume of the dosing unit dosing/temperature curves and reports for the lab journal can be printed out gradient dosing gradient dosing with serial control of up to four dosinos dose a fixed volume with or without pauses at a defined rate e.g 230 ml at 22.5 ml/min with temperature monitoring if required the liquino calculates and


safety first programming of a sequence seq free programming of a dosing sequence allowing the combination of different dosing modes this makes complex dosing profiles possible each step mode has its own parameters between the sequences pauses date time or time interval of any length can be inserted a sequence may also contain additional auxiliary instructions e.g to control external instruments scan control or to control the sequence pause timer storage of dosing sequences once the dosing sequences have been optimized the corresponding methods can be stored on a memory card and reproduced at the press of a key safety with exothermic reactions optional pt 100 temperature sensors in four-wire technique with «synthesis-proof» ptfe shafts are used for the temperature monitoring during dosing tasks upper and lower limits with individual alarm outputs complete the safety measures if a limit is exceeded this can be made to stop the dosing automatically or to switch on or off a heating or coo


maximum accuracy outstanding precision pump the dosing error and the repeatability are better than required by din 12650 in terms of accuracy and repeatability the dosino is far superior to volumetric standard glassware the resolution of the cylinder volume amounting to 10 000 steps allows precise dosing at rates that can be set between 0.0015 ml/min and 9.96 l/h auto control with built-in glp test for the automatic validation of the pump or cylinder respectively the 711 liquino is connected to a balance via its rs 232c interface the integrated glp dosing program automatically doses the liquid into a vessel tared on the balance calculates the volume of the liquid dosed and compares it to the nominal volume the validation report conforming to glp appears on the connected printer expansion possibilities the rs 232c interface built in as standard allows the remote control and programming of all dosing functions from a pc printer for the comprehensive documentation of parameter settings an


technical specifications of the 711 liquino short description compact multi-functional dosing and control instrument for synthesis in the laboratory and plant four dosing instruments and 1 temperature sensor can be connected connections for dosing instruments maximum 4 dosing instruments maximum 2 of them can be active at the same time type of dosing instrument 700 dosino buret cylinder volumes 2 5 10 20 or 50 ml resolution 10 000 steps per buret volume range of dosing rates from 0.0015 ml/min to 166 ml/min 9.96 l/h temperature sensor input sensor pt 100 measuring method four-wire technique constant current measuring range 5 ma ­40 240 °c time clock battery-buffered memory ram battery-buffered 64 kb power connection voltage frequency 100 120 v ± 10 220 240 v ± 10 50 60 hz memory card type memory card according to standard jeida 4.x pcmcia 2.x 68 pins power consumption ca 28 va dimensions height width depth weight 2.36 kg without accessories and without keypad 208 mm 96 mm 208 mm capaci


measuring controlling dosing in synthesis 9


718 synthesis controller 718 synthesis controller ­ every synthesis laboratory needs one ­ at the very least the 718 synthesis controller stat titrino and the 711 liquino complement each other ideally whenever you have to keep the ph value constant and at the same time need to dose various liquids under strictly defined conditions the 718 synthesis controller not only distinguishes itself by its compactness ­ its surface area is smaller than a4 format it is also extremely versatile all functions are easily accessible using the separate keypad its large method memory stores the optimized sequences during a control task the measured value as well as the reagent volume added always appear on the display the instrument settings can be viewed at any time and adjusted «live» as required detailed monitoring of the reaction rate the 718 synthesis controller is the specialist for applications involving the kinetics of acid-base or redox reactions up to nine time windows can be set for the calcu


security through monitoring printer and pc glp and iso 9000 demand the complete documentation of the determinations for the printing of results and the corresponding instrument settings including the instrument identification number economical printers can be connected to the 718 synthesis controller backup copies of the user methods are indispensable in a glp-compliant laboratory.this backup can be performed vith the vesuv 3.0 metrodata pc program vesuv 3.0 allows you to collect measured data and results from one ore more instruments and to recalculate the results it also offers convenient database functions such as data export filtering and searching ´fr 718 stat titrino 0p1/123 718.0012 date 2002-03-26 time 11:16 3 phcinit 3.00 stat ph antacdet c80 m.rate 0.1214 0.00093 ml/min 1 fix v1 1.143 ml 450 s fix v2 1.989 ml 900 s 2 fix v3 3.468 ml 1620 s fix v4 3.694 ml 1800 s fix time 1319.8 s 0.25 vtot fix time 2835.5 s 0.5 vtot 3 fix time 31527.1 s 0.9 vtot fix time 41800.0 s 1 vtot st


technical specifications of the 718 synthesis controller 718 stat titrino operating modes stat set dos doc maintenance of a pre-defined ph or mv value titration to a pre-defined endpoint set endpoint titration dosing run a gradient of the measured value polarizer ipol upol display backlit lcd 2 lines of 24 characters each character height 5 mm rs 232c interface printer or balance connection or pc connection «remote» conventional i/o lines connection of a sample changer or a laboratory robot analog output recorder connection for plotting as a function of time the measured value measured value drift volume and volume drift as well as setpoint deviation in the stat or set mode safety specifications construction and inspection according to iec publication 348 safety class i ­127 127 a ­1270 1270 mv dosing volume of a buret cylinder resolution 1 5 10 20 or 50 ml 10 000 increments per buret volume power requirements voltage frequency 100 117 220 240 v ± 10 selectable 50 60 hz power consumpti


ordering information options ordering information for 711 liquino 711 liquino compact control unit with memory card for various dosing applications with up to four 700 dosinos mini-din plug connection possibility for temperature sensor pt 100 for simultaneous monitoring of the reaction temperature built-in rs 232c interface db9 for balance printer or pc 2.711.0010 2.700.0020 including memory card and keyboard 700 dosino drive for dosing unit together with which it is screwed directly onto bottles with gl45 glass thread 1 l reagent bottles from baker and riedel-de haën adapters see below fixed cable 2 m with 8-pin mini din plug for connection to the 711 liquino dosing units with glass cylinder for 700 dosino including accessories dosing unit 2 ml with titration and dosing tip dosing unit 5 ml with titration and dosing tip dosing unit 10 ml with titration and dosing tip dosing unit 20 ml with titration and dosing tip dosing unit 50 ml with titration and dosing tip dosing units with etf


ordering information options 6.2141.090 6.2134.110 6.2134.050 6.2125.040 6.2125.030 6.2125.020 6.2134.000 6.2125.080 6.2125.060 6.2134.040 cables for connecting metrohm instruments to the 711 liquino connecting cable 711 liquino ­ titrino connecting cables for printer balance and pcs cable for custom dp40-s4n and seiko dpu 414 printers db9 cable for epson fx lx lq printers cable for epson ex 800/lq 850 printers din connector stackable plug for the simultaneous connecting printer and balance cable for mettler balances ae 011/012 as well as for and balances for mettler balances am at pm use mettler cable me 33995 and and for mettler balances ab ag interface lc-rs25 cable for sartorius balances mp8 and mc1 cable for precisa balances cable for pc with 25-pin connector db25 cable for pc with 9-pin connector db9 requires additional 6.2125.010 adapter cable rs 232c 9 pin ­ 25 pin ordering information for 718 synthesis controller 718 synthesis controller stat titrino compact titrator for soph


ordering information options 6.2125.130 6.2125.050 6.2125.040 6.2125.030 6.2125.020 6.2125.070 6.2125.080 6.2125.060 6.2125.110 6.6008.200 6.6008.500 connecting cables for printer balance and pcs cable for custom dp-40-s4n and seiko dpu 414 printers db9 cable for epson fx lx lq printers cable for epson ex 800/lq 850 printers din connector stackable plug for the simultaneous connection of printer and balance cable for mettler balances ae 011/012 as well as for and balances for mettler balances am at pm use mettler cable me 33995 and for mettler balances ab ag mettler interface lc-rs25 cable for sartorius balances mp8 and mc1 cable for precisa balances cable for pc with 25-pin connector db25 cable for pc with 9-pin connector db9 metrodata vesuv© 3.0 metrodata vesuv 3.0 including hardware dongle for max x instruments metrodata vesuv 3.0 light including hardware dongle for max 2 instruments pc program windowstm 95 98 nt or 2000 for the aqcuisition of titration data via an rs 232c interface