i onanalysis 844 uv/vis compact ic metrohm first-class ic
|
compact · · · · · · · · first integrated compact uv/vis ic system worldwide favorable purchase price and operating costs easy and powerful system control with ic net or ic cap software small footprint means very small space requirements high precision and high measuring accuracy low detection limits peek flow path fully solvent-compatible high quality system and components made in switzerland 2
|
technology · diode-array detector · 3 wavelengths plus freely selectable reference wavelength · peak-ratio channel · variable bandwidths for detection wavelength peak bunching · scan mode for spectra recording and simple system optimization · combined uv and vis lamp system · no lamp change · integral post-column reactor pcr · column heating · gradient capability 3
|
instrument the 844 uv/vis compact ic is a complete small-footprint chromatography system that separates and determines substances that absorb in the ultraviolet or visible part of the spectrum the introduction of this system opens a wide range of applications that are not directly accessible to ion chromatography with conductivity detection some important application fields are · · · · · · detection of heavy metals wastewater containing chromium in leather production corrosion checks in power plants determination of bromate in drinking water analysis of sulfur compounds in wastewater measurement of nitrite and nitrate in seawater in the 844 uv/vis compact ic all system components are integrated into its compact protective housing injector high-pressure pump with gradient capability column heating post-column reactor reagent pump and the newly developed diode-array uv/vis detector the complete system is capable of being controlled simply by pc via the robust ic net software allowing for
|
conductivity or uv/vis ion chromatography focuses on many ionic components in our environment whether nutrients or pollutants drinking water or wastewater pharmaceutical products or contaminants in them ic permits reliable analytical statements about their ionic composition ion chromatography has the aim of first separating the ionic substances and then quantifying them reliably as we are dealing with ions detection is usually performed with a conductivity detector if matrix effects or inadequate separation of the analyte ions negatively affect conductivity detection or even render it impossible then the use of an alternative detection method can supply important knowledge should conductivity detection not produce a result then the absorption of ultraviolet or visible light by the sample may yield the correct analytical solution a prerequisite is that the substances absorb part of the light passing through them 5
|
ic with metrohm ion chromatography with metrohm means · · · · · · fast start-up easy operation high sensitivity precise and reproducible results excellent price-performance ratio low operating costs very low maintenance and · made in switzerland high-precision instruments that are unrivaled throughout the world «metrohm first-class ic» 6
|
simple and logical operation ic net software simultaneous representation of three wavelengths the absorption spectrum can also be shown at any time each wavelength can be configured individually 7
|
optimization the ic net software allows you to measure and compare the absorption at different wavelengths in a very easy way this function can also be used for assessing the peak purity prontosil 120-5-c18-aq 150 x 4.0 6.1008.100 20 mmol h2so4 in 15/85 v/v acetonitrile/water 1 ml/min sample volume 20 µl 220 nm black 254 nm red 270 nm green peak-ratio channel blue no 1 2 3 analyte paracetamol caffeine hydroxybenzoic acid conc mg/l 20 20 20 applications a few examples from our application library determination of heavy metals standard nucleosil 5sa 125 6.1007.000 70 mmol/l tartaric acid ph 3.3 nh3 flow 1.0 ml/min sample volume 100 µl vis 530 nm pcr with par no 1 2 3 4 5 6 7 ion copper lead zinc nickel cobalt cadmium manganese conc mg/l 1.0 1.0 1.0 1.0 1.0 1.0 1.0 determination of chromate aqueous leather extract after dialysis metrosep a supp 5 150 6.1006.520 4.0 mmol/l nahco3 12.8 mmol/l na2co3 flow 0.7 ml/min sample volume 50 µl vis 540 nm pcr with diphenylcarbazide dilu
|
determination of nitrite and nitrate in sea water artificial sea water metrosep a supp 5 250 6.1006.530 1.0 mmol/l nahco3 3.2 mmol/l na2co3 flow 0.7 ml/min sample volume 10 µl uv 215 nm dilution 1:10 no 1 2 3 ion chloride nitrite nitrate conc mg/l 0.1 0.1 determination of bromide 1 salt solution nacl metrosep a supp 5 250 6.1006.530 11.0 mmol/l nahco3 0.5 mmol/l na2co3 flow 1 ml/min sample volume 20 µl uv 205 nm with chemical suppression for removing carbonate no 1 ion bromide conc mg/l 0.29 determination of bromate drinking water herisau switzerland bromate column 6.1005.110 100 mmol/l h2so4 flow 1 ml/min sample volume 1 ml uv 352 nm pcr with ki and ammonium molybdate no 1 ion bromate conc µg/l 0.13 determination of sulfide sulfite and thiosulfate standard metrosep a supp 5 100 6.1006.510 4.0 mmol/l na2co3 flow 0.7 ml/min sample volume 1000 µl uv 205 nm no 1 2 3 4 determination of caffeine in cola drinks cola drink prontosil 120-5-c18-aq 150 x 4.0 6.1008.100 25 mmol/l kh
|
technical information compact high-performance ion chromatography system with uv/vis detection multi-wavelength detector · 3 wavelengths · 1 reference wavelength · 1 peak-ratio channel · measuring range from 190 900 nm · resolution 2.5 x 107 au · noise 1 x 105 au · drift 5 x 104 au/h · combined deuterium/halogen lamp system switchable separately preadjusted · scan mode for rapid determination of absorption maxima · separate analog output for each wavelength · zero function · variable bunching factors for each wavelength high-pressure pump · metal-free low-pulsation dual piston pump · flow range 0.2 to 2.5 ml/min typical working range 0.4 to 1.5 ml/min · maximum pressure 35 mpa 350 bar 5000 psi · flow correction · high-pressure gradient capability chromatography system · built-in 6-way injection valve · pulsation absorber · insulated column compartment · column heating for 2 separation columns control range ambient temperature +5 °c to 75 °c included in versions 0110 and 0120 versi
|
ordering information 2.844.0010 compact ion chromatograph for the photometric determination of anions and cations in the uv/vis range very compact design system with built-in dualpiston high-pressure pump electrically operated injection valve and high-sensitivity 3-wavelength diode-array detector compact ion chromatograph for the photometric determination of anions and cations in the uv/vis range very compact design system with built-in dualpiston high-pressure pump electrically operated injection valve and high-sensitivity 3-wavelength diode-array detector additionally equipped with pcr postcolumn reactor and 2-channel peristaltic pump compact ion chromatograph for the photometric determination of anions and cations in the uv/vis range very compact design system with built-in dual-piston high-pressure pump electrically operated injection valve and high-sensitivity 3-wavelength diode-array detector additionally equipped with column heating for 2 separating columns compact ion chromatog
|
i onanalysis metrohm ltd ch-9101 herisau/switzerland phone +41 71 353 85 85 fax +41 71 353 89 01 www.metrohm.com info@metrohm.com subject to modifications layout by ecknauer+schoch asw printed in switzerland by metrohm ltd herisau 8.844.6003 2005-06
|