792 basic ic where and how can ion chromatography be taught and learned up to now only complex or expensive solutions were possible metrohm s answer is different 792 basic ic ion chromatography
|
another step forward towards training explains the basics the 792 basic ic is an instrument that students can use to familiarize themselves with the basics of ion chromatography in a very simple way as ion chromatography belongs to the hplc family the basics of this technique are also acquired the software program allows the operator to create various hardware systems and to operate them with different methods it is possible to develop and save one s own methods for each experiment and each application detailed description of 22 experiments the training manual takes into account different levels of education learners concerning themselves with the subject of ion chromatography for the first time will find just as much useful and above all understandable information as students who have already gained some experience in the field of chromatography deals with your applications of course the 792 basic ic is not just limited to the teaching and training sectors but it also carries out va
|
combines teaching and practice the 792 basic ic is controlled by the pc ic for everyone metrohm aims to cover all areas of ion chromatography competently and at a very high level this begins with simple systems for routine applications and the 790 personal ic it is continued by the 761 compact ic which offers lower detection limits and additional flexibility the modular ic system based on the two main components 819 advanced ic detector and 820 advanced ic separation center is the top system for the laboratory sector the powerhouse for process control in industry and in the power plant sector is the 811 online ic 792 basic ic with the 792 basic ic metrohm offers two different things in the first place this unusually favorably-priced ic instrument enables schools universities advanced training institutes as well as in-house training laboratories to acquire one or more ion chromatographs and to equip the training facilities with the required workplaces secondly metrohm has published
|
the highlights at a glance the highlights at a glance the latest ion chromatograph from the series of metrohm ic compact instruments covers the fields of instruction and training in ion chromatography the 792 basic ic follows the vision that metrohm has developed for ion chromatography manufacturing ic systems that have a high performance work reliably are easy to use and nevertheless are still affordable some of the far-reaching possibilities of ion chromatography previously had to be left unused as the costs of the instruments were too high thanks to metrohm it is possible today for everyone to utilize this potential the 792 basic ic is a fully fledged ion chromatograph incorporating the time-proven metrohm components · thermally insulated and electronically shielded housing · high-performance conductivity detector temperaturestabilized at 40 °c temperature stability better than ±0.01 °c · low-pulsation double piston pump no external gas supply is necessary · electric six-way injec
|
running costs that don t run wild the 792 basic ic stands out by its low acquisition and operating costs low operating costs for all metrohm instruments including the new 792 basic ic the term «cost of ownership» has achieved great importance this covers the operating costs associated with the instrument with the basic ic these are unusually low it requires no expensive external gas supply as the built-in double piston pump naturally provides an adequate performance the ic pump also ensures a constant low-pulsation flow and therefore guarantees a steady baseline the injection valve also works without needing nitrogen or helium this saves costs if the metrohm suppressor module «msm» is operated correctly its lifetime is practically unlimited carbonate/hydrogen carbonate eluent dilute sulfuric acid and water for regeneration and rinsing the suppressor all the necessary solutions are cheap to prepare even with a high sample throughput the operating costs can be kept very low that the so
|
experiments contained in the training manual experiments covering the theory of ion chromatography experiment 1 ion chromatography with and without chemical suppression experiment 2 capacity of separating columns experiment 3 selectivity of separating columns experiment 4 calibration detection and determination limits in ion chromatography experiment 4a determining anions with chemical suppression experiment 5 altering the selectivity with the aid of crown ethers 18 crown-6 experiment 6 altering the selectivity by using complexing agents experiment 7 preconcentration technique determination of anions experiment 8 determining anions in drinking water experiment 9 anions in ethanol and spirits liquor experiment 10 anions in lettuce experiment 11 phosphoric acid in cola drinks experiment 12 organic acids in wine experiment 13 determination of contaminants in borate chloride and sulfate in borax experiment 14 determination of anions in wastewater experiment 15 fluoride in toothpaste expe
|
ordering information technical specifications ordering information 2.792.0020 metrohm 792 basic ic for the determination of anions with or without chemical suppression and determination of cations without chemical suppression especially suitable for training includes extensive training manual eluent organizer for the convenient arrangement of the bottles for the eluent and for the regeneration solutions for the «msm» comprises three bottles plus additional accessories basic ic starter kit consisting of metrosep anion dual 1 anion column 150 mm with holder also includes pulse dampener technical specifications compact ion chromatography system with pc control · built-in six-way injection valve · low-pulsation double-piston pump flow rate 0.2 2.5 ml/min maximum pressure 25 mpa 250 bar 3625 psi · thermally and electrically insulated column compartment · stability of the detector temperature better than ±0.01 °c temperature 40°c measuring range 0 1000 µs/cm · two-channel peristaltic pump
|