822 titration curve simulator diagnostic tool for the quick and easy testing of titrators simulates reproducibly · acid-base titration with one equivalence point · citric acid titration with three equivalence points · conditioning for karl fischer titration · karl fischer titration
|
the diagnostic tool for potentiometric and test to be certain metrohm instruments are known for their precision and reliability thanks to their robust construction they are hardly ever affected by external mechanical or electrical influences even though a malfunction can never be completely excluded it is normally due to operator errors faulty connections or third-party instruments should you ever suspect a fault in a metrohm instrument it is always advisable to localize the problem using fast and easy to perform diagnostic tests these diagnostic tests require tools that are not readily found in the laboratory the 822 titration curve simulator is such a tool it is connected instead of the electrode is extremely easy to operate and allows to generate potentiometric as well as karl fischer titration curves by means of these curves you can rapidly gauge the proper functioning and the accuracy of the instrument concerned 822 titration curve simulator with 808 titrando and titration curve
|
karl fischer titrators how does it work as a function of the dispensed volume the 822 titration curve simulator generates a voltage that changes with each dosing step the resulting sshaped curve can have one or more equivalence points and is suitable for all current metrohm titration systems the titration curve data are digitally stored in the curve simulator this allows one to obtain strictly reproducible equivalence points delicate evaluation occasionally it may happen that previously found equivalence points suddenly are no longer evaluated is it the chemistry the solvent the electrodes or even the titrator or has there been a sudden change in the sample these are the questions that confront the analyst the titration curve simulator also generates extremely flat curves that nevertheless can be evaluated if your titrator is able to evaluate such curves an instrument fault can be excluded this means that the range of possible error sources is reduced quickly and economically practic
|
technical specifications curve types acid-base citric acid conditioning karl fischer analog output voltage range ambient temperature nominal operational range storage transport power supplied by titrator voltage power consumption dimensions width height depth weight without accessories 704 g 2500 2500 mv +5 45 °c at max 85 humidity 40 70 °c 40 70 °c +5v +12 v 0.1 w 150 mm 41 mm 118 mm 4 diagnostic tool for the analytical laboratory
|
essential features status control lamps of 822 information on bus activities the leds represent the serial information in parallel form response of dosing system to the bus activities switch for selecting between msb-controlled dosing systems serial 25 bit and serially controlled dosing systems with 8 bit preselector switch for the different titration curves 822 titration curve simulator simulated sample addition for karl fischer titrations titrator connection either direct or via adapter connection for external dosing system analog output for the measuring signal is connected to the titrator rear view of 822 titration curve simulator diagnostic tool for the analytical laboratory 5
|
ordering information 2.822.0010 titration curve simulator diagnostic tool for titrators supplies strictly reproducible data for acid-base titrations citric acid titration three equivalence points karl fischer titration and conditioning for karl fischer titration allows to check the proper functioning of the electrode inputs the dosing outputs and the evaluation software of the titrator power supplied by the titrator to be tested which titrators can be tested with the titration curve simulator as a rule all metrohm titrinos titroprocessors 726 796 and titrandos can be tested with the 822 titration curve simulator the required cables or adapters are included in the standard accessories of the 822 titration curve simulator subject to modifications printed in switzerland by metrohm ltd herisau 8.822.6003 2003-04 6 diagnostic tool for the analytical laboratory
|