Page 76 of MFJ 2006 Catalog by MFJ Enterprises, Inc.
76 www.ameritron.com
QSK-5 Pin Diode Xmit/Receive Switch... $349
Worlds most advanced
Transmit/Receive Switch.
Gives high power QSK operation from your linear amplifier.
Self-contained, connects externally to most HF
amps. Handles 2.5 kW PEP, 2 kW CW. Six
times faster than vacuum relay.
ARF-1000 RF Filter . . . $159
Use with transceiver or amplifier
that produces unwanted harmonics.
Frequency select switches to 1 of
six different ranges, 1.5-30 MHz. When the filter
is selected it reduces harmonics above cut-off frequency. Handles 1 kW SSB input power, 600W
CW or 400W RTTY. SWR less than 1.3:1 on all
ham bands. SO-239 in/output. 5 1/2Wx3 1/2Hx9 1/2D .
ATP-100 AMP Tuning Pulser . . . $49 95
Pulse tuning safely tunes up your amp for
full power output and best linearity.
Keeps average power to low safe level to
prevent overheating, tube damage,
power supply stress and premature
component failure. ATP-102, $59 95,
similar, variable pulser and delay.
Add-on Electronic Bias System . . . $39 95 for
AL-80A/82/1200/1500 Amps
EBS-1, $39.95. EBS reduces heat
by reducing quiescent current to
low values during periods when
exciter output falls below 100 mW.
Features remote detector board.
EBS-1H, $49.95, for other amplifiers. Call 662-323-8211 for details.
ICP-120/240 Inrush Current Protector . . . $79
Stops power-up inrush current and
absorbs momentary high voltage spikes
to protect your amp, tubes and power
supply components. By starting your
linear amplifier through a high power
current limiting resistor and then
shorting the resistor with a relay, the
start-up sequence is easier on your
tube and power supply components.
Avoids replacing expensive tubes and
parts. Works with nearly all linear
amplifiers. Limits current to 12
Amperes during heavy draw inrush period, 20
Amperes during continuous operating current.
ICP-120, $79, for 120 Volt wired amplifiers.
ICP-240, $79, for 240 Volt wired amplifiers.
AMERITRON Amplifier-to-Transceiver Interface
AMERITRON has the best selection of high power accessories!
ADL-1500 Dummy Load with oil . . . $69 95
Oil cooled 50 Ohm dummy load
handles 1500 Watts for 5 minutes.
SWR under 1.2 to 30 MHz. Low
SWR to 400 MHz. High quality
industrial grade transformer oil (no
PCB), heavy duty 50 Ohm resistor. ADL-
1500X, $49.95. Dummy load without oil.
ADL-2500 Fan cooled 2500W dry dummy
load ... $199 95
Whisper quiet fan. Handles
any legal limit amplifier 2500
Watts average power for 1
minute on, ten off. 300 Watts
continuous. SWR below 1.25 to
30 MHz and SWR below 1.4 to 60 MHz.
Ameritrons
flat Mobile
Peak Reading
SWR/Wattmeter is just 1 5/8 thick easily
mounts on your dashboard for easy viewing.
Flat mount on wall or shelf in your ham
shack for best viewing angle. Remote sensor with 25 feet thin, flexible cable lets you
place sensor and coax out-of-the-way.
Handles full 1500 Watts, 1.8-30 MHz.
Lighted Cross-Needle meter. Active electronics lets you read true peak or average
power in 3000/300 Watt ranges. High SWR
LED. 5Wx3 1/4Hx1 5/8D sensor is 3 1/2Wx2 3/4H
x2 3/4D . Use 9V battery or 12 VDC.
AWM-30 Precision SWR Wattmeter . . . $149 95
This precision SWR/Wattmeter is perfect for making
accurate linear amplifier power
measurements. Reads true peak
or average power on lighted
cross-needle meter.3000/ 300
Watt ranges, remote sensor.
Use 9V battery or 12 VDC.
Flat Mobile Wattmeter mounts on dashboard . . . AWM-35, $159 95
Amplifiers
can damage
radios if the
amplifier has
too much relay
control voltage, voltage spikes,
or excessive current on the
relay control line.
The ARB-704 advanced
interface is compatible with all common
radios and amplifiers even though radios
and amplifiers do not have standardized
voltages, accessory plugs, or wiring. Designed to work with any amp/radio combo.
The input is designed to be compatible
with any transmitter or transceiver, and the
output is compatible with AC or DC positive or negative amplifier control lines having up to 200 Volts peak open circuit voltage
and 300 mA of current.
Operates with rigs that pull amplifier
control lines to ground, or output a wide
range of positive or negative control voltages. Dont take a chance! Get the ARB-
704 now! 4 1/4Wx1 3/4Hx2 3/4D . Power cord,
3 phono cords for relay/ALC/control included.
Extra cable, $15.95 for following rigs:
Model#
Transceivers
PNP-8D
FT-1000, (MP), 900, 767GX, 920, 990, 747GX
PNP-8M
FT-890, 840, 817, 857, 897
PNP-35
FT-100, (D)
PNP-5M
FT-847
PNP-7D
TS-440, 690, 450, 180, 140, 950, 130, 870, 2000,
50, 120, 530, 430, 830, 949, 570
PNP-13D
All models of the IC-706 series
PNP-7DK
TS-930
PNP-7DK2
TS-520
PNP-8MK
TS-480
PNP-5D
FT-980
PNP-8DI
ICOM ACC JACK
ARB-704
$49 95
ARB-704I2
for IC-706s
AMERITRON RCS-4 Remote Coax Switch
Ameritron RCS-4 is a
remote controlled coax
switch that selects 1 of 4
outputs by supplying all
control voltages through the coax.
Elimination of control cables gives you
a fast, neat and inexpensive installation -only 1 coax line for 4 antennas.
You get two units the switching box
(5 3/8Dx7Wx3H inches.) that can be tower,
mast or wall mounted and the control console (6 1/8Dx5 1/4Wx 3 3/8H inches.) that is
located at your operating station.
The attractive indoor console has bright
LED antenna selector indicators.
A steel enclosure provides 100% shielding to prevent RFI and TVI.
Switching time is 50 milliseconds.
Teflon (R) SO-239 connectors provide reliable connections.
The weatherproof switching box uses
three heavy duty 16 ampere hermetically
sealed relays on a rugged G-10 fiberglass
circuit board.
Quality components are used throughout the entire unit to ensure maximum life
for the sometimes difficult-to-reach switching box.
RCS-4 operates 120 VAC. RCS-4X for
220/240 VAC. RCS-4 allows safe operation with 14 Volts control voltage.
Frequencies 1.5 60 MHz are covered
by this excellent station accessory.
Handles 2.5 killoWatts.
Specifications:
4 pos.;
Loss at 30 MHz less than 0.1 dB;
VSWR is under 1.25:1, 1.5-60 MHz;
Impedance: 50 Ohms;
Power: 2.5 kW average continuous.
Lightning Protected
model RCS-4L, $179
RCS-4
$139
Suggested
Retail
A plug-and-play cable is not
needed if your radio is not listed.
[close]