Catalog: General Product Catalog 2008
Company/Brand: Midwest Electric
circuit breaker 20 amp in General Product Catalog 2008 by Midwest Electric
service equipment surface 200a metered barrier 200 main main space ... space space space space 200 barrier space space 20 200 main load ... spacespacespacespace load 200 load 200 main main 200 main space 50 space 200 ... space load spacespacespace 200 load m208cr2b010 series a r281c1 series ... c r200t series d m254c series e main 200 load main 225 nonauto metered overhead ... cb2200b cb120 cb4200h cb4200h installed breaker spaces 4 4 2 7 wire range an bk af bd s ... -tap 3 load lugs per phase 3 225 amp non-auto switch no circuit protection ...

supplied with factory installed main breakers rated 22kaic where applicable · units ... with or without load center with 8 circuit models being standard other ... lugs provided on load centers with main breakers service equipment 1 · 320 amp ... compartment has barrier from main circuit breakers for utility power protection ... series wired 240v single phase branch circuits accept combinations up to 200a · heavy ... number ms45500c ms45508c installed breaker cccc 400amp ringless with lever bypass ... rs43308c rs45500c rs45508c installed breaker b bbbaaaa 1st opc device rating 150 ... amp 150 amp 200 amp 200 amp 2nd opc device rating 150 amp 150 amp ... 200 amp 200 amp 1st opc device rating 200 amp 200 amp 2nd opc device rating 200 ...

polyester powder coat finish · 22,000 amps rms symmetrical short circuit rating · ... points · units provided with 200 amp continuous 120/240 v single phase 4-jaw ... meter socket 198b8601g78 · 300 amp 400 amp series-wired main bus units ... on models with or without main breaker · lockable sealable covers provided ... mobile home service entrance powerhead 20 200 amp main 00 main breaker not ... for field installation only main breaker amp rating 20 head only shown mh1 ... socket b no loadcenter bolt-on main breaker installed separate breaker for each ... meter s two circuit 100 amp convertible plug-in load center pc2lc ...

temporary power unmetered space 20 20 20 20 spac gfi gfi e 20 20 gfi 20 20 2 5- ... 20r2gfci temp power power outlets a u011c010 2 5 ... -20r2 b u011g 14-30r c u030 6-20r d u036c 5-20r2 6-20r e u036c033 5- ... 20r2gfci 3 20 20 gfi 20 20 20 space gfi 20 20 20 space 20 20 20 space 20 20 20 ... spac gfi gfi e 6-20r f u036g 5-20r2 6-20r g u038c010 2 5-20r2gfci 6-20r h ... u038c033 2 5-20r2gfci 6-20r i u038ctl010 2 5-20r2gfci 6-20r j ... u038g 2 5-20r2 fig ul model number receptacles ... abdefcyyyyyu011c010 u011g u030 2 5-20r2gfci 2 5-20r2 14-30r circuit protection 2 ... wire cabinet hub load unit std amp volts range size opening neutral bar wt ...
power receptacles are available in 20 30 or 50 amp configurations protected ... by thermal magnetic circuit breakers ground fault breakers are also ... power receptacles are available in 20 30 50 or 100 amp configurations ... protected by thermal magnetic circuit breakers ground fault breakers are also ...

shall be equipped with at least one 20-ampere 125-volt receptacle a minimum of 5 ... supply shall each be equipped with a 50-ampere 125/250 volt receptacle conforming to ... supply shall each be equipped with a 30-ampere 125-volt receptacle conforming to ... -81 dedicated tent sites with a 15 or 20-ampere electrical supply shall be permitted to ... vehicle sites with 30 or 50-ampere receptacles additional receptacles ... the recreational vehicle park the 2002 national electric code requires ... means a disconnecting switch or circuit breaker shall be provided in the site ... here all 125-volt single-phase 15 and 20-ampere receptacles shall have listed ground- ... fault circuit-interrupter protection for personnel transformer ... reducing installation time · 200 amp loop-feed lugs have twin 2-250 mcm ...

vehicle park equipment pedestal 50 20 50 20 20 space main s p 20 20 a gfi gfi ... c e 30 20 space 30 20 gfi space 30 30 20 gfi post 2 14-50r post b u011cp6010 2 5 ... -20r2gfci post c u011gp6 2 5-20r2 post r32u post r32u post 14-50r a ... u004cp6010 5-20r2gfci d u041cp6010 5-20r2gfci e u041gp6 5-20r2 f u042gp6 5-20r2gfi 50 ... 20 50 30 20 spacesp 50 30 20 aspce 50 30 20 a gfi c e 30 30 20 20 ... a u004cp6010a g u043gp6 5-20r2 post 14-50r post 14-50r 14-50r h ... u055cp6010 5-20r2gfci i u075cp6010 br32u 5-20r2gfci j ... u075cp6010d br32u 5-20r2gfci k u075gp6 br32u 5-20r2 2 br32u post l ... u131cp6010 2 5-20r2gfi 5 model number receptacles 2 5-20r2gfci ... r32u 5-20r2gfci r32u 5-20r2 2 5-20r2 2 14-50r 5-20r2gfci circuit protection ...

available photocell not shown 20 amp available with gfi breaker or gfi ... and easy night time plug in · 4-circuit load center installed lc44x1 · service ... power receptacles are available in 20 amp 30 amp or 50 amp configurations ... protected by thermal magnetic circuit breakers ground fault breakers are also ... of power center location light circuit is protected by a 20 amp circuit ... breaker light cover molded of lexan® ... coax cable · electrical rating of 100 amp max 120/240 volt 1Ø-3 wire with ground ... shroud are tan in color · standard 200a/350kcmil lugs installed in pedestal ... models · amp rating 200 amp on back-to-back 100 amp on single · ...

pad mount post most common receptacle/circuit breaker combinations straight blade ... receptacles 14-50r 50 amp 125/250 v 14-50r 50 amp 125/250 v with ... gfi breaker r32u 30 amp 125 v r32u 30 amp 125 v with gfi breaker 5-20r2 20 amp ... 125 v gfci duplex 5-20r2 20 amp 125 v duplex with gfi breaker not used ... meter adder electronic metering 200 amp rated use with 125v receptacles j n h ... meter two meters electronic metering 200 amp rated use with 125/250v ...

to-back pedestal most common receptacle/circuit breaker combinations partial listing ... for marina products l6-50r 50 amp 125/250 v locking type l5-50r 50 amp ... 125 v locking type l5-30r 30 amp 125 v locking type l5-30r 30 amp 125 v ... locking type with gfi breaker 5-20r1 20 amp 125 v straight blade with gfi breaker 5 ... -20r2 gfci duplex 20 amp 125v straight blade under flip cover on ... post 100 amp iec-309 pin/sleeve type 125/250 v not ... list price $418 $730 $647 $1,287 $1,203 $1,107 $1,287 $829 $966 list price $258 ... $213 $74 $194 $194 $204 $947 non-metallic marina back-to-back ... 3 note receptacles cannot exceed 120 amps per side code aa aq au aw cq ac as cm ...
inlets fig ul u022n also has 2 cb120 circuit breakers and one breaker space cs6375 ... u050n u030n u020n receptacles 2 l14-20 cs6375 l14-30 l14-20 amps 40 50 30 20 ...
parts accessories circuit breakers code midwest model number single pole ... thql1150 thql1140 thql115 thqp115 15 20 30 40 50 20 15 1 module g.e model ... number 1/2 module amp voltage no of poles circuit breaker ... cb240 thql2130 cb250 thql2140 20 thql2150 30 40 30 50 models ending ... in t 1/2 thinline breakers not available for all load centers ... thql2160 thqp250 thqp230 thqp220 20 cb2200b models ending in t 1/2 ... thinline breakers not available for all load centers ... tqdl21150 thql21100 thql2170 60 50 200 100 200 70 120/240 120/240 120/240 120/ ... thql2140gf thql2130gf 50 40 30 20 30 20 15 120/240 120/240 120/240 120/ ... /240 120/240 2 2 2 2 1 1 1 ground fault circuit interrupter ground fault circuit ...