Catalog: General Product Catalog 2008
Company/Brand: Midwest Electric
general electric meters in General Product Catalog 2008 by Midwest Electric
midwest electric products inc is pleased to introduce ...
how to use this catalog model diagram symbol key meter socket meter socket circuit breaker installed 1-pole plug-in style circuit breaker installed 1-pole plug-in style circuit breaker installed 2-pole plug-in style circuit breaker installed 2-pole plug-in style circuit breaker space 1-pole plug-in style circuit breaker space 1-pole plug-in style timer timer circuit breaker space 2-pole plug-in style circuit breaker space 2-pole plug-in style ge kr style ge kr style main breaker ge kr style ge kr style main breaker space for receptacle identification see application data for receptacle identification ...

product features pedestal unit · ul listed · nema 3r construction for rainproof installation · barriers available for line · continuous duty meter socket · utility accepted meter protection available with meter guides and reinforced jaws ringless and ring type meter not included load and meter socket isolation · heavy zinc coated steel with highest quality electrodeposition finish resists corrosion and fading · molded thermal plastic load center interior for maximum isolation and reliability · rolled door edge for cord · circuit breaker mains · additional breaker spaces · dead front construction ...
service equipment where electrical power enters a building or other ... structure the national electrical code nec requires electrical ... service entrance for mobile homes is generally located within 30 feet of the mobile ...
service equipment surface 100a metered service equipment 1 barrier barrier space space space space space 20 20 space space space barrier space space space space barrier 100 main space 100 main space space 100 space space space space space space 100 20 space space 100 load load space 100 main spacespacespacer101cb2 series a r101cb2010 series b r102cb2 parallel c m102cb2010 parallel d parallel r100c e r101c series fspacespacespacespacespac e 100 load parallel r102e g r100t series h overhead/underground feed fig a b d model number r101cb2 r101cb2010 m102cb2010 installed breaker cb2100 spaces 5 ...

service equipment surface 125a metered service equipment space space ms125e series a side by side overhead/underground feed fig a model number ms125e installed breaker none spaces 2 wire range bc cabinet 16 x 17 size load center pc2lc unit wt 24 std pkg 1 ul y 150a metered main barrier 150 main load spacespacespacespacespace spacespacespacespace main 150 load 150 load load m181cb1 series c rs150c series d ms151c series e overhead/underground feed fig c model number r181cb1 installed breaker cb4150h spaces 4 wire range bg cabinet size 14 x 28 side by side overhead/underground feed fig d e ...

service equipment surface 200a metered service equipment 1 main 200 load spacespacespacespacespace main 200 load space space space space space space space space spacespacespacespacespace 200 load side by side overhead/underground feed fig abcd rs250c series a rs251c series b ms252e014 parallel c ms252c parallel d model number rs250c rs251c ms252c installed breaker cbl2201 lcb2201 cb2201 spaces 0 5 5 wire range bc bc cabinet 17 x 26 size 17 x 26 17 x 26 load center lc55n1 lc55n1 lc88x2 unit wt 41 39 41 std pkg 1 1 1 ul y y y ms252e014 1 8 bc bc 14 x 31 43 1 y barrier space space space ...

service equipment surface 200a metered barrier 200 main main space space space space space 200 barrier space space 20 200 main load spacespacespacespace load 200 load 200 main main 200 main space 50 space 200 space load spacespacespace 200 load m208cr2b010 series a r281c1 series b m282c1c parallel c r200t series d m254c series e main 200 load main 225 nonauto metered overhead feed fig b a r280t series f load m285t series g model number r281c1 r200t 2 m208cr2b010 cb2200b cb120 cb4200h cb4200h installed breaker spaces 4 4 2 7 wire range an bk af bd s bj cabinet size 14 x 38 9 x 30 9 x 30 load ...

400amp features service equipment all-in-one · ul listed suitable for use as service equipment panelboard no 67 and meter sockets no 414 · units supplied with factory installed main breakers rated 22kaic where applicable · units available with or without load center with 8 circuit models being standard other configurations available consult manufacturer · load centers are provided with copper bus 22 kaic bus bracing and 100 neutral terminations feed-through lugs provided on load centers with main breakers service equipment 1 · 320 amp continuous duty meter socket available in ring-type k-4 bolt ...

service equipment pedestals 100a metered service equipment load load load load 100 main spacespacespace 100 main spacespacespace 100 main spacespacespace 100 main spacespacespacer101cp6 series a r101cb6 series b r101cp6hp series c r101cb6hp series d metered inline post fig a model number r101cp6 installed breaker cb2100 spaces 3 wire range t2 cabinet size 9pt load center lc55n1 unit wt 59 std pkg 1 ul y metered inline back to back fig b model number r101cb6 installed breaker cb2100 spaces 3 wire range t2 cabinet size 9pt load center lc55n1 unit wt 82 std pkg 1 ul y metered head post fig c ...

200a metered service equipment pedestals service equipment 1 50 space space space 100 space space load space space space space load 50 space space 50 space space space space space space gfi 20 200 main 200 main 200 main 200 main 200 200 main load spacespacespacespace load load 14-50r space load space r208cp6hp series a r211cp6 series b r225cp6 series c 14-50r m254cp6 series d 14-50r m255gp6 series e 5-20r2 r2502cp6 parallel f space 200 200 main load spacespacespacespace space space space load load spacespacespacespace load space 200 load load space load space space space space space space space ...

service equipment pedestals 200a metered service equipment 200 main load spacespacespacespace space load load spacespacespacespace load space 200 load load space load load spacespacespacespacespace spacespacespacer281c1b6h series a r281e1b6h series b r282c1b6h parallel c m282e1b6h parallel d metered head post back to back fig b d a model number r281e1b6h r281c1b6h installed breaker cb4200h cb4200h spaces 4 4 5 5 wire range ssss cabinet size 6h 6h 6h 6h c r282c1b6h lctnl lctnl lctl lctl load center top bottom lcbs lcbs lcbs lcbs unit wt 101 101 101 101 std pkg 1 1 1 1 ul yyyy florida ...

service equipment lever bypass 200a metered barrier barrier space space space space space space space space barrier barrier 200 main 200 main load load space load load 200 main load load load spacespacespacespacespace spacespacespacespacespace spacespace metered lever bypass overhead/underground feed fig b a r281cb1034 r208cr2a034 r208cr2a034 series a r281cb1034 series b r281eb1034 series c r281c1034 series d model number installed breaker cb4200h cb2200b spaces 4 8 loop feed lugs installed c r281eb1034 4 120/240 120/240 120/240 volts phases 1 1 wire range bk bk cabinet size 14 x 32 14 x ...

200a metered service equipment lever bypass service equipment 1 barrier load load load load load load load load barrier 200 main space 100 main 200 main space load load spacespacespacespacespace spacespacespacespacespace spacespacespacespacespace spacespacespacespacespace post r281c1p6h034 series e post r281e1p6h034 series f post r481c1p6h034 series g post r281c1b6h034 series h post r281e1b6h034 series i metered lever bypass pedestal fig e f r281c1p6h034 r281e1p6h034 model number installed breaker cb4200h cb2100 spaces 4 4 120/240 volts phases 1 1 wire range s s cabinet size 6h034 6h034 g ...

service equipment technical data m101c m100c model number hub opening y m101cb2 m101cp6 y msm100930 msm100p9 msm100p9 msm10014 msms1 mw200m mw200m mw200m msm100p9 msm100p9 msm10014 m101cb6 y msm100930 9 x 30 9pt m101cb6hp m102cb2 m102e m200t m101cp6hp m181cb1/gp nyyyynny lt100b250 lt100s350 lt100s350 lt100b350 14 x 26 9hp 14 x 26 14 x 38 14pt 9hp 6h 6h 14pt 14 x 28 9 x 30 9hp 9pt 9 x 30 c c 30 a d 26-1/4 30 9-3/4 b see page 31 see page 31 see page 31 14-1/4 9-3/4 5-3/16 c 5-3/16 3 4-9/16 3 10,000 10,000 6 10,000 10,000 10,000 10,000 msm100930 cdcd 26-1/4 38-3/8 38 28-5/8 ...

service equipment technical data 1 r100c r100t model number hub opening service equipment y r101c y msr100930 msr100p9 mw200r mw200r meter socket replacement parts post lugs r101cb2010 r101cp6 r101cb6hp r101cb6 r101cb2 r102e r200t r102cb2 r101cp6hp nyyynnnyyy msr100930 cabinet size 9 x 30 enclosure style page 29 height cabinet dimensions width 9 x 30 c msr100p9 msr10014 mw200r mw200r msrs mw200r msr100p9 msr100p9 msr100p9 lt200s350 lt100s250 lt200b350 lt100b250 14 x 26 9hp 14 x 26 14 x 38 14 x 28 14pt 14pt 14 x 28 9 x 17 9hp 9pt 9pt 14 x 26 9 x 30 c 30 a c 30 9-3/4 b depth ...

service equipment technical data rs45500c rs45508c u101c u102e u101cp6 u154c u208c u180c1 u181c1 u208cp6hp u280c1 u281c1 u281e1 u281c1p6h u281e1p6h ul412rmw model number hub opening y y y msr249 msr249 30 x 33 30 x 33 9 x 17 9pt e e 33 17-3/8 17-3/8 21-3/4 21-3/4 33 a 30-3/8 30-3/8 see page 32 9-3/4 9-5/16 9-5/16 14-3/4 4-3/4 9-3/4 b 6-1/8 5-3/16 5-3/16 6-7/16 4-3/4 4-3/4 6-1/8 c ¿ ¿ 3 22,000 10,000 10,000 22,000 nyyyynyyyyyyy lt100s250 lt200s350 b 14 x 21 9 x 21 9 x 21 14pt 9 x 17 baab 21-3/8 3 11 11 5 5 10,000 10,000 22,000 22,000 10,000 22,000 ...

service equipment post dimensions 9pt earth burial single head post double head post back to back 14pt earth burial unmetered a 65 b c 19-1/8 d 9 e 4-3/8 f 18 g 6 metered 77-1/2 45-1/4 19-1/8 9 4-3/8 18 6 single head post double head post back to back powerhead 9 x 30 14hp earth burial abcdefg metered 100a 200a 83-1/2 83-1/2 51-1/4 48-3/4 47 47 9 9 4-3/8 4-3/8 18 18 6 6 powerhead 14 x 38 14 x 21 single head post double head post back to back powerhead 14 x 34-1/2 unmetered metered a 83-1/2 86 b 50 c 49-1/2 49-1/2 d 9 9 e 4-3/8 4-3/8 f 18 18 g 6 6 ...

service equipment post dimensions 6h earth burial service equipment 6h034 earth burial 1 some models available in 4-3/8 contact distributor/manufacturer unmetered a 83-1/2 b c 46-1/2 d 9-1/2 e 3-1/2 f 18 g 6 x 21-1/2 y 9-1/2 metered 84 51-1/2 46-1/2 9-1/2 4-1/2 18 6 30 9-1/2 abcdefgxy metered 83-1/2 49 46-1/2 9-1/2 4-1/2 18 6 35 14 400 amp wire range and knockout detail table 400a line load 1 neutral n1 equip grnd connector crimp-on/connector lug is not supplied by midwest a 1-1/2 2 2-1/2 f 1/2 g 1/2 3/4 1 l 1/2 3/4 t 3-1/2 4 v 3/4 1 1-1/4 1-1/2 ...

service equipment table aw line load neutral equip grnd service equipment connector copper aluminum solid strand solid strand table bd line load neutral equip grnd 1/0-4/0 1/0-4/0 1/0-4/0 1/0-4/0 2-4/0 2-4/0 12-8 12-2 12-8 12-2 connector copper aluminum solid strand solid strand table bj meter line socket base load lugs neutral a neutral/grnd b neutral/grnd c 1/0-4/0 1/0-4/0 2-4/0 1/0-4/0 2-4/0 1/0-4/0 12-8 12-2 12-8 12-2 connector copper solid strand 14-8 6-4/0 1-4/0 1-4/0 6-2/0 14-4 1 table ax line load neutral a neutral b neutral c equip grnd ...
is easily installed by a single electrician · direct burial post mounted units ...
service equipment mobile home technical information basic models mp100b0 mp120b0 model number 1 service equipment post models listed also available as head only substitute mh for mp socket position 1 1 powerheads 1 1 socket rating 200 amp 200 amp 200 amp main breaker empty 200 amp empty 1 loadcenter type lug lug breaker panel wiring series series series mh mp weight weight 22 22 48 22 48 48 mp100s0 mp200b0 mp200s0 mp300b0 2 1 125 amp 2 ckt convertible lug lug breaker mp220b0 mp300s0 mp320b0 mp400b0 2 1 2 1 200 amp 3 1 200 amp 3 2 200 amp 3 2 200 amp 200 amp empty 125 amp 2 ckt convertible ...
site equipment from midwest electric combines the required components in a ... -power fully meets the 2002 national electrical code and osha requirements temp power ...
temporary power metered 20 20 spacespa 20 20 gfi gfi c e 20 20 gfi 20 20 2 5-20r2gfci gfi gfi 6-20r metered top feed fig ul abyyr011c010 r011g e r036g 5-20r2 6-20r f r038c010 2 5-20r2gfci 6-20r g r038c033 2 5-20r2gfci 6-20r barrier 20 20 20 20 20 space 20 20 20 space 20 20 20 spacehm038cb1010 2 5-20r2gfci model number receptacles 2 5-20r2gfci 6-20r 5-20r2gfci 6-20r 5-20r2 2 5-20r2 circuit protection 2 cb120 space cb120 cb220 cb120 2 gfi120 space cb120 gfi230 cb120 wire cabinet hub load unit std amp volts range size opening neutral bar wt pkg 100 40 100 40 120/240 120/240 aa aa 9 x 30 9 x 30 ...

temporary power metered barrier gfi barrier 20 20 20 space gfi 20 20 20 space 20 20 20 spac gfi gfi e gfi 20 20 20 space gfi 20 20 20 space 50 20 6-20r temp power power outlets a m038cb1033 5-20r2gfci 6-20r post b r038cp4033 5-20r2gfci 6-20r c r038g 2 5-20r2 6-20r d m038gb1 2 5-20r2 6-20r e m038gb1033 2 5-20r2gfci 10-50r f m051c010 5-20r2gfci 3 50 20 50 20 gfi 50 gfi 20 50 20 gfi gfi 50 20 10-50r metered top feed fig ul a y m038cb1033 r038cp4033 r038g m038gb1 m038gb1033 m051c010 g m051g 5-20r2 14-50r h r055c010 5-20r2gfci 14-50r i r055c033 5-20r2gfci 14-50r j r055g 5-20r2 14-50r post k m055gp6033 ...

temporary power metered 20 20 spacespac gfi gfi e 20 20 gfi 30 20 50 20 20 space gfi 50 20 20 14-50r 20 20 20 20 20 20 gfi 20 20 20 space 6-20r metered top feed continued fig ul abyyr076c010 r076c033 f r036cu 5-20r2 6-20r g r036c010u 5-20r2gfci 14-30r h r036c033u 5-20r2gfci 6-20r i r038c010u 2 5-20r2gfci model number receptacles 14-50r 2 5-20r2gfci circuit protection cb250 2 cb120 space cb120 gfi250 2 cb120 space cb120 wire cabinet hub load unit std amp volts range size opening neutral bar wt pkg 90 120/240 aa 9 x 30 y lc55n1 25 1 90 120/240 aa 9 x 30 y lc55n1 24 1 metered bottom feed fig ...

temporary power metered gfi 20 20 20 space 20 20 20 spac gfi gfi e 50 20 50 gfi 20 50 20 50 20 20 gfi space 6-20r 2 5-20r2gfci 6-20r temp power power outlets a r038c033u b r038gu 2 5-20r2 14-50r c ro55c010u 5-20r2gfci 14-50r d ro55c033u 5-20r2gfci 14-50r e ro55gu 5-20r2 14-50r f r076c010u 2 5-20r2gfci metered bottom feed continued fig ul model number receptacles abcefyyy r038c033u r038gu 6-20r 2 5-20r2gfci 2 5-20r2 3 circuit protection gfi220 2 cb120 space cb120 cb250 cb120 2 gfi120 space cb120 gfi250 cb120 wire cabinet hub load unit std amp volts range size opening neutral bar wt pkg 100 ...

temporary power technical data model number replacement parts m076c033 r011c010 r011g m076c010u m076c010 m055gu m055gp6033 m055g m055c033u m055c033 m055c010u m055c010 m055c m051g m051c010 m038gu m038gb1033 m038gb1 m038g m038cb1033 m038cb1010 m038cb1 m038c033u m038c033 m038c010u m038c010 msm100930 msm100ez msm10014 msm10014 msm10014 msm100ez 9 x 30u 9 x 30u 14 x 26 14 x 26 9 x 30 9 x 30 14 x 26 9 x 30 14 x 26 14 x 26 9 x 30 ccbbbb msm100930 msm100ez msm10014 msm10014 msm100930 msm100930 msm100930 msm100930 msm100930 msr100930 msr100ez msr100ez msr100930 msr100930 msr100930 msr100930 msm100930 msm100ez ...

temporary power technical data model number replacement parts meter socket cabinet size enclosure style page 57 height cabinet dimensions width r055c010 r038gu r055c010u r055c033 r055g r055gu r055c033u r076c010 u011c010 u011g msr100930 msm100930 msr100930 msr100930 msr100930 msr100ez msr100ez msm100ez msr100ez msr100ez 9 x 30u 9 x 30u 9 x 30u 9 x 30u 9 x 30u 9 x 30 6 x 14 6 x 14 9 x 30 9 x 30 9 x 30 9 x 30 cccccbaabbbb 30 a 30 9-3/4 b depth 30 9-3/4 5-3/16 c knockout figure page 57 30 9-3/4 5-3/16 3 30 9-3/4 5-3/16 2 30 9-3/4 5-3/16 3 30 9-3/4 5-3/16 2 temp power power ...
portable equipment requiring electricity continues to increase steadily in both ... for cord connected equipment midwest electric power outlets provide one or more ...
power outlets surface main s p a 20 c gfi espace 50 20 50 20 gfi a u361g 2 5-20r2 b u501 6-50r 6-50r c u511c 5-20r2 6-50r d u511g 5-20r2 e u546 14-60r 14-50r f u550f 5-20r2 30 30 30 30 space 30 s p a 20 20 c gfi gfi e 50 30 spacespacespace 50 2 r32u surface unmetered bdefcayyynyyu501 u361g g u614c 2 br32u 10-30r h u666c010 2 5-20rgfci i u870g/u870g6 l6-30r 2 l5-20r 14-50r j r058c r32u k m354c 14-50r fig ul model number receptacles 2 5-20r2 6-50r 5-20r2 6-50r circuit protection gfi120 cb250 cb120 fh2 wire cabinet hub load unit std amp volts range size opening neutral bar wt pkg 50 70 120/240 ...

power outlets pedestal 50 30 spacespace 30 30 30 space 50 30 50 30 spacespace 30 spacespace 30 30 30 30 30 post post post post 14-50r post b u132cp6 r32u post c u061cp6 2 r32u 14-50r a u058cp6 r32u d u058cb6 r32u e u132cb6 r32u f u061cb6 2 r32u 50 30 50 30 spacespace 50 30 30 spacespace 30 spacespacespacespacespace 50 spacespacespace 50 30 spacespacespace 50 post 14-50r post r32u post r32u post post h m132cp6 r32u post i m354cp6 14-50r 14-50r pedestal unmetered fig ul abyygr058cp6 r32u j r058cb6 k m132cb6 l m354cb6 14-50r model number u058cp6 2 u132cp6 2 u061cp6 2 receptacles 14-50r r32u r32u ...

power outlets technical data model number m058c m058cb6 m067cr2 m132cb6 m132cp6 m354c m354cp6 m358cp6 r058c u002c r058cp6 r058cb6 m354cb6 msm100930 msm100p9 msm100p9 msm10014 meter socket replacement parts post lugs lt100b350 lt100b350 lt100s250 lt100b350 lt100s250 lt100s250 lt100b350 cabinet size 9 x 30 9pt 9pt 9pt 9pt 9pt 9 x 30 9pt 9pt 9pt enclosure style page 68 height cabinet dimensions width b b 30 38-3/8 a 9-3/4 b depth 14 x 38 14-3/4 see page 68 5-3/16 6-3/8 c knockout figure page 68 2 5 msm100930 msm100p9 msm100p9 msm100p9 msr100p9 msm100p9 see page 70 see page 68 see ...

power outlets technical data model number u061ctl u070c u075c u132cb6 meter socket replacement parts post lugs cabinet size 9 x 17 9 x 17 9 x 17 6pt 6pt enclosure style page 68 height cabinet dimensions width a a a 17-3/8 17-3/8 17-3/8 a 9-3/4 9-3/4 9-3/4 b depth 5-3/16 5-3/16 5-3/16 c knockout figure page 68 2 2 2 u132ctl u354c u501 u511c u546 u550f u154f u361g u511g u614c u132cp6 lt100s250 lt100b250 see page 68 14 x 21 9 x 17 6 x 14 6 x 14 6 x 14 6 x 14 6x9 5x7 9 x 17 aaaaaaaa 17-3/8 17-3/8 14-3/8 14-3/8 14-3/8 9-1/8 7-1/8 21-3/8 14-1/4 ...

power outlets post dimensions 6pt earth burial unmetered a c 19-3/4 d 6-1/2 e 3-1/4 f g 18 6 62 6pt pad mount unmetered c 17-3/4 e d 6-1/2 3-3/4 a 36 single head post single head post double head post back to back temp power power outlets double head post back to back 3 9pt earth burial unmetered b 9 a 64-1/2 c 19-1/8 d f e 3-1/4 g 18 6 metered 77-1/2 9 45-1/4 19-1/8 3-1/4 18 6 9pt pad mount unmetered b 9 a 41-1/8 c 19-3/4 d metered 45-1/2 3-1/4 9 53-1/2 19-1/2 some models available in 4-3/8 contact distributor/factory e 3-1/4 single head post double head post ...
telephone cable tv connections and electric metering valox thermoplastic enclosure ... telephone cable tv connections and electric metering factory wired power ...

every recreational vehicle site with electrical supply shall be equipped with at least ... of all recreational vehicle sites with electrical supply shall each be equipped with a 50 ... as identified in figure 551-46c these electrical supplies shall be permitted to include ... of all recreational vehicle sites with electrical supply shall each be equipped with a 30 ... of all recreational vehicle sites with electrical supply shall be equipped with one or ... tent sites with a 15 or 20-ampere electrical supply shall be permitted to be ... be permitted for the connection of electrical equipment outside the recreational ... vehicle park the 2002 national electric code requires application information ... for your unique application midwest electric offers a complete line of power outlets ... park application that meet the national electrical code standard power outlets post ...

recreational vehicle park equipment surface space 50 20 50 20 20 s p a 20 20 c gfi gfi e 5-20r2gfci a m004c010 2 14-50r 2 5-20r2gfci b m011c010 r011c010 2 5-20r2 c m011g r011g r32u d m031c010 r031c010 2 5-20r2gfci 30 20 space 30 s p a 20 c gfi e 50 20 br32u rv products surface metered fig ul bayym004c010 e m041c010 r041c010 5-20r2gfci br32u f m041g r041g 5-20r2 14-50r g m055c010 r055c010 5-20r2gfci 5 model number ring type ringless m011c010 r011c010 receptacles 2 5-20r2gfci r32u 2 5-20r2gfci br32u 5-20r2gfci br32u 5-20r2 2 5-20r2 5-20r2gfci 2 14-50r circuit protection 2 cb120 space cb120 2 cb250 ...

recreational vehicle park equipment 50 20 gfi 50 30 20 space 50 30 s p a 20 c gfi e 50 20 20 space 50 20 spacespace 50 s p a 20 c gfi espace 14-50r surface metered fig ul a y m055g a m055g r055g 5-20r2 14-50r b m075c010 r075c010 br32u 5-20r2gfci 14-50r c m075g br32u 5-20r2 14-50r d m076c010 r076c010 2 5-20r2gfci 14-50r e m355c010 5-20r2gfci 14-50r f m355g r355g 5-20r2 model number ring type ringless r055g m075c010 m075g m076c010 m355c010 m355g r075c010 r076c010 r355g receptacles 14-50r br32u 5-20r2gfci 14-50r br32u 5-20r2 14-50r 5-20r2 circuit protection cb250 cb130 cb120 space cb120 cb250 ...

recreational vehicle park equipment pedestal 50 20 50 30 20 space 30 20 s p a gfi c e 50 20 gfi 50 30 20 space 2 14-50r post a m004cp6010 1 5-20r2gfci br32u post post br32u post 14-50r post 14-50r b m041cp6010 r041cp6010 5-20r2gfci c m041gp6 r041gp6 5-20r2 d m055gp6 5-20r2 e m075cp6010 r075cp6010 br32u 5-20r2gfci space 50 30 20 s p a gfi cespacespa 20 c e 50 20 50 gfi spacespace space space space space 50 50 20 gfi space 50 20 30 post 14-50r post 5-20r2 14-50r post 14-50r post 5-20r2 fig ul a y m004cp6010 ring type model number ringless receptacles br32u 5-20r2gfci br32u 5-20r2 2 14-50r 5-20r2gfci ...

pedestal recreational vehicle park equipment 30 20 space 30 20 space 30 20 s p a gfi c e 30 20 s p a gfi c e 50 30 20 space 50 30 20 space 50 30 20 s p a gfi c e 50 30 20 s p a gfi c e post br32u post 5-20r2gfci br32u post 5-20r2 14-50r post 5-20r2gfci 14-50r a m041cb6010 b m041gb6 r041gb6 c m075cb6010 br32u d m075gb6 r075gb6 br32u 5-20r2 space space space 50 space space space space space space 50 50 20 s p a gfi cespace 50 20 s p a gfi cespace space space space space space space space 50a 50a 20a 30a 50a 50a 20a 30a gfi space space post 14-50r post 5-20r2 14-50r gfi 20 20 pedestal metered back ...

recreational vehicle park equipment lighted rv 30 20 space 50 30 20 space br32u surface unmetered fig ul abyyau041ctll10 5-20r2gfci br54u b u075ctll10 br32u 5-20r2gfci lug type model number u041ctll10 u075ctll10 receptacles br54u br32u 5-20r2gfci br32u 5-20r2gfci loop feed loop feed circuit protection cb250 cb130 cb120 space cb130 cb120 amp 100 100 volts 120/240 120/240 wire cabinet hub load unit std range size opening neutral bar wt pkg w 9 x 17 9 x 17 n lc33n1t 14 1 w n lc55n1t 16 1 wire range table on page 97 30 20 space 50 30 20 space 50 30 20 space 50 30 20 space post br32u post space 14-50r ...

recreational vehicle park equipment technical data model number m004c010 m011c010 m011g m004cp6010 m031c010 msm100930 msm100p9 msm100p9 meter socket replacement parts post lugs lt100s250 cabinet size 9 x 30 9pt enclosure style page 94 height cabinet dimensions width b 30 30 a msm100930 9 x 30 m041c010 msm100930 msm100ez msm100p9 msm100p9 msm100p9 a a m041cb6010 m041cp6010 m041g m041gb6 m041gp6 m055g m055c010 m055gp6 m075c010 m041c010u msm100930 9 x 30 b see page msm m011c010 95 9-3/4 9-3/4 9-3/4 9-3/4 9-3/4 b depth 5-3/16 5-3/16 c knockout figure page 94 2 9 x 30 b m041cp4l10 ...

recreational vehicle park equipment technical data model number r076c010 r355g u004cb6010 r355gp6 r075gp6 r075gb6 meter socket replacement parts msr100930 msr100930 msr100p9 msr100p9 b lt100s250 lt100b350 post lugs cabinet size 9 x 30 9 x 30 9pt 9pt 9pt 9pt enclosure style page 94 height cabinet dimensions width a see page 95 9-3/4 9-3/4 see page 95 see page 95 see page 95 see page 95 b depth c knockout figure page 94 b b 30 30 5-3/16 5-3/16 2 2 u010c010 u010g u011c010 u004cp6010 lt100s250 lt100b350 lt100s250 6x9 9pt u011ctl010 u011gp6 u011gb6 u011g u011cp6010 lt100s250 ...

recreational vehicle park equipment technical data model number u131cp6010 u355g u355c010 u131ctl010 u076g u076c010 u075gtl u075gp6l u075gp6 u075gp4l u075gb6 u075ctll10 u075ctl010 meter socket replacement parts post lugs lt100b350 lt100s250 lt100s250 cabinet size 9 x 17 9pt 9pt 9 x 17 enclosure style page 94 height cabinet dimensions width a a 17-3/8 17-3/8 a 9-3/4 9-3/4 b depth see page 95 see page 95 see page 95 see page 95 5-3/16 5-3/16 c knockout figure page 94 2 2 lt100s250 9pt 9pt lt100b250 9 x 17 14pt 9 x 17 9 x 17 aaaa 17-3/8 21-3/8 17-3/8 ...

recreational vehicle park equipment post dimensions 6pt earth burial unmetered a c 19-3/4 d 6-1/2 f g 18 6 e 3-1/4 62 6pt pad mount unmetered a e c 17-3/4 d 6-1/2 3-3/4 36 single head post single head post double head post back to back double head post back to back 9pt earth burial unmetered a b 65 9 6 c 19-1/8 d f e 3-1/2 g 18 metered 77-1/2 19-1/8 3-1/2 18 6 9 45-1/4 9pt pad mount unmetered b 9 a 41-1/8 c 19-3/4 d e 3-1/2 metered 53-1/2 19-1/2 rv products 45-1/2 3-1/2 9 some models available in 4-3/8 contact distributor/factory single head post double head ...
telephone cable t.v connections and electric metering all this in one attractive ... in the quality tradition of midwest electric products inc electronic digital meter ... suitable for type rg-59 coax cable · electrical rating of 100 amp max 120/240 volt 1Ø- ...
· individual site metering to recover electrical costs rv products installation ... · unitized service panel to accept electrical components telephone cable tv and ...
125v receptacles j n h i one meter two meters electronic metering 200 amp rated ... 125/250v receptacles k g one meter two meters list pri $116 $162 $112 $47 rv ...
and attractiveness the 2002 national electrical code requires application information ... the locking and grounding types midwest electric offers a complete line of metered and ...
marina products dockpro® · · · · · thermoplastic nema 3r enclosure with aluminum extrusion frame 360° fluorescent or incandescent lighting for better visibility electronic metering option water shroud is included ul cul listed power phone tv under same door dockmaster® · · · · injection molded ge thermoplastic energy saving fluorescent light electronic metering option water shroud option ul cul listed crisp clean appearance · power phone tv under same door · · · dockmate® · · · · · marina products 6 electronic metering option water shroud option injection molded ge thermoplastic power center ...

marina products dockpro electronic meter window this dimension varies based on hose bib selected 20 gfci or ph/tv under flip cover 100 a pin sleeve receptacle twist lock 20a 30a or 50a locking receptacle mounted underneath in-use cover hose hanger hose bib secondary side plumbing primary side terminal bar all dimensions are in inches dockmaster electronic meter window lens for light top light meter window 13.06 13.06 breakers access panel 42 tv receptacles telephone water bracket for faucet 14.7 interior dockmaster bottom of base 13.62 all dimensions are in inches dockmate 41.5 10 12.75 20.75 ...
uwater34 3/4 hose bib vmaster1s 125v electric meter kit single vmaster2s 125v ... electric meter kit dual vmaster1d 125/250v ... electric meter kit-single vmaster2d 125/250v ... electric meter kit-dual for use on dockmate ... receptacles e b p i h one meter two meters electronic metering use with 125/ ... 250v receptacles d w one meter two meters use box below for appropriate meter ...
flexibility features and benefits electrical ratings rugged durability gs1201b20ul ...
transfer switches fig a single phase utility single phase switched neutral fig b -n utility fig c three phase utility load load load standby -n standby standby single phase 120/240 volts ac fig ul aayy model number gs3161g gs1101b12ul main standby 200 200 400 400 100 100 100 200 200 400 100 100 amps aaaayyyy gs1201b20ul gs1202b20ul gs1402b01ul 120/240 120/240 120/240 120/240 120/240 120/240 volts phase 1 1 wire range cual 12-1/0 6-250 6-250 12-1/0 included order separately hub 1 1 4 unit wgt 31 11 std pkg 1 1 1 1 neutral kits field installed only order model installed neu202 neu202 neu407 neu407 ...
installed cost features and benefits electrical ratings · 200 main amp rating · ul ...
parts accessories post extensions kit consists of 1 post extension bracket 2 1/2 bolts 2 1/2 nuts 4 1/2 flatwashers dimensions 18 l x 6 w or 9 w ek126 6pt 6 post models ek129 9pt 9 post models mounting bracket 265a6218g1 for mounting fs box to post for field installation of tv or telephone jacks post stake add cw for wepco approved model kit consists of 1 post stake bracket 2 1/2 bolts 2 1/2 nuts 4 1/2 flatwashers dimensions 44 l x 3 w or 1 d ms62 sealing ring tie bars snpr1 snap-on style sealing ring for ring-type meter sockets 121 asr1 screw style sealing ring for ring-type meter sockets ...

parts accessories lug assemblies part number ni60b2 neu102 ni100b2 neu202 ni200 ni200a5 neu407 ni400a1 gl3 gl6 lug size and qty 4 14-4 cu al 5 12-1/0 cu al 5 14-1/0 cu al 2 14-1/0 3 6-250kcmil cu al 31/0-250kcmil 3 12-1/0 cu al 31/0-250kcmil 3 12-1/0 cu al 2 14-1/0 3 2-600kcmil 21/0-600kcmil 31/0-250kcmil cu al 2 12-2 cu al 1/0 ground lug ni60b2 neu102 ni100b2 neu202 ni200 ni200a5 neu407 ni400a1 gl3 meter door replacement kits gl6 lic metered units please consult manufacturer to ensure the proper kit is ordered for your model meter door replacement kits are available for service entrance temporary ...
lever bypass for 034 models midwest electric manufactured meter socket only 2 ...
msrp ms200lbm ms5 5th jaw1 1 midwest electric manufactured meter socket only mounts ...