LVS DIN SERIES 2016-08-25 by Mitsubishi Electric Factory Automation

More catalogs by Mitsubishi Electric Factory Automation | LVS DIN SERIES 2016-08-25 | 4 pages | 2019-12-12

Ads

Contacts for Mitsubishi Electric Factory Automation

Catalog LVS DIN SERIES 2016-08-25

LVS DIN SERIES 2016-08-25 is listed under these categories

Industrial Supply

Featured catalog pages of LVS DIN SERIES 2016-08-25

factory automation din series miniature circuit breakers residual current circuit breakers ƒƒ all models fully comply with iec regulations ƒƒ high current-limiting performance ƒƒ c  ompliance with ip2x protection rating front surface ƒƒ all models are compatible with reverse

miniature circuit breakers/residual current circuit breakers characteristics product line-up model type mcb rccb no of poles [p rating instantane voltage [v ous tripping short-cir compliance cuit capacity standard [ka bhw-t10 1 2 3 4 6 to 63 a 0.5 to 63 a type b type c d 240/415 ac 10 iec 60898-1 bvw-t 2 1+n 4 3+n 16 to 63a — 240/415 ac — iec 61008-1 bhw-t10 model type wiring diagram short-circuit capacity instantaneous tripping model type and rated current residual current circuit breakers rccb automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity and also fulfills the function of isolation high short-circuit current withstand capacity with backup protection fuse explanation of markings example model type bhw-t10 fire resistant plastic parts endures abnormal heating and strong impact construction features independent of power supply and line voltage and free from external interference voltage fluctuation state of

miniature circuit breakers/residual current circuit breakers ordering information miniature circuit breakers mcb reference 1 1 residual current breakers rccb codes reference 1 codes type b 1 pole 2 poles 3 poles 4 poles 30 ma 2 poles 4 poles bhw-t10 m type b 6 a 291889 291908 291917 291926 bvw-t m 25a 30 ma 293548 293603 bhw-t10 m type b 10 a 291890 291909 291918 291927 bvw-t m 40a 30 ma 293550 293605 bhw-t10 m type b 16 a 291891 291910 291919 291928 bvw-t m 63a 30 ma 293551 293606 bhw-t10 m type b 20 a 291892 291911 291920 291929 300 ma 2 poles 4 poles bhw-t10 m type b 25 a 291893 291912 291921 291930 bvw-t m 25a 300 ma 293598 293613 bhw-t10 m type b 32 a 291894 291913 291922 291931 bvw-t m 40a 300 ma 293600 293615 bhw-t10 m type b 40 a 291905 291914 291923 291932 bvw-t m 63a 300 ma 293601 293616 bhw-t10 m type b 50 a 291906 291915 291924 291933 bhw-t10 m type b 63 a 291907 291916 291925 291934 type c 1 pole 2 poles 3 poles 4 poles bhw-t10 m type c 0,5 a 291953 291968 291983 291998

miniature circuit breakers/residual current circuit breakers specifications mcb rccb type type bhw-t10 no of poles [p 1 instantaneous tripping 2 iec/en 60898-1 icn number of operating cycles 1 ac 2 3 rated current in [a at ambient temperature 30° c 660 0.5 1 2 3 4 5 6 10 16 20 25 32 40 50 62 240 v 10 10 240 v 415 v 10 10 — 10 — 415 30 300 max operating time at ign [s 0.04 pulating current sensitivity type ac rated making and breaking capacity im [a 500 in 25 40 a 630 in 63 a rated residual making and breaking capacity igm [a 500 in 25 40 a 630 in 63 a rated conditional short-circuit current inc [ka 10 5 rated conditional residual short-circuit current igc [ka without current with current type of overcurrent release number of operating cycles thermal-magnetic mounting applicable wire size 1 to 25 mm2 mass [kg 0.13 0.26 0.39 0.52 0.13 0.26 0.39 0.52 terminal connection — mounting iec 35 mm rail applicable wire size 1 to 25 mm 2 0.22 0.44 solderless based on