shaping the future of factory automation networks with the creating automation q61p q25hcpu qd81dl9 mode run err user bat at boot controller ntroller distributed cont control 6 qj71gp2 1-sx qj71c24r2 qy42 y4 p pull pull usb max.1 gbps melsecnet/h anywire cc-link is a high-speed and high-reliable deterministic i/o control network which realizes reduced wiring whilst offering multi-vendor compatible products this open field network is a global standard originating from japan and asia max 2.5 mbps cl2x16-d1 m1v s3d cl1pad1 cc-link/lt is a wire-saving sensor level network which is designed for use in panels between simple discrete devices its wiring system is based on reducing incorrect wiring and is based on cc-link realizing high-speed and robust noise resistance features easy installation using dedicated connectors the point mode setting 4 8 or 16-point mode enables effective use of i/o points the maximum link points is 1024 points in the 16point mode cl2y8-tp1b2 1d lc 2x1

innovation in shop floor safety cc-link safety a safety field network cc-link safety has been developed to reduce risks on the shop floor and to realize a safe work environment by connecting safety devices which detect errors in the production line and the safety programmable controller which stops the production line by signals from the safety devices with simple wiring accidents can be prevented during operation in addition cc-link safety can greatly reduce wiring for the safety system hazards of production lines mechanical hazard world wide safety ï¼»international safety standards compliantï¼½ conforms to the international safety standards iec 61508 sil3 and en954-1/iso 13849-1 category 4 to meet safety needs at global production sites safety assurance and wiring reduction ï¼»inherited cc-link functionsï¼½ noise/vibration hazard electrical hazard transmission speed of 10 mbps equivalent to cc-link is realized allowing use of the same cc-link cables and connection

cc-link cc-link/lt provide various useful functions device layout as we need cc-link allows flexible installation cc-link family remote i/o modules occupy a small footprint t-branch repeaters wireless optical repeaters optical repeaters and repeater hubs are available with cc-link they enhance the freedom of application even at 10 mbps repeater hub compact type remote i/o modules with 32 16 8 4 and 2 i/o points are available they can be installed in six different directions including ceiling installation front installation and flat surface installation and selected according to the installation environment and the application 1 4 5 6 7 8 direct installation on machines in 6 directions aj65fbt-rph power run sd rd unit power master station l1 rd l2 rd l3 rd l4 rd err 156k 625k 2.5m 5m 10m l5 rd l6 rd l7 rd l8 rd link1 link5 link2 link6 link3 link7 link4 link8 remote i/o station remote device station intelligent device station local station etc front installation front installation flat

case 2 mr b from the production section trunk cables and branch cables in the current network are different furthermore trunk cables are expensive mr b is in charge of production engineering he has been worried about utilization and high cost of the existing network therefore he collected cc-link information and compared it with other networks feature 1 cc-link is flexible to install feature 2 cc-link is reasonably priced cable comparison item other network cc-link cable diameter 7 mm thick cable 12 mm thin cable 7 mm trunk branch trunk and branch trunk branch total cable length no repeater max 1200 m 156 kbps max 500 m 125 kbps max 100 m 125 kbps 250 kbps 500 kbps it is stressful to design the necessary power supply capacity of a network he used to be bothered by complicated calculations for the required power capacity he soon learned that such bothersome calculation was not necessary feature 3 case 3 the calculation of the power supply capacity is not required for cc-link mr c

screw/2-piece terminal block type aj65btb features the i/o terminal block is removable the 2-piece structure allows easy servicing as the module can be replaced without rewiring the terminal block can be removed input modules model aj65btb1-16d aj65btb2-16d dc dc number of input points 16 16 input format positive/negative common positive/negative common input response time ≤ 10 ms ≤ 10 ms rated input voltage/current 24 v dc/7 ma 24 v dc/7 ma external connection 1-wire type 2-wire type output modules model aj65btb1-16t aj65btb2-16t aj65btb2-16r output format transistor sink type transistor sink type relay number of output points 16 16 16 leakage current at off ≤ 0.1 ma ≤ 0.1 ma output protection function no no no rated load voltage/current 12/24 v dc 0.5 a 12/24 v dc 0.5 a 24 v dc/240 v ac 2 a external connection 1-wire type 2-wire type 2-wire type i/o combined modules model input format aj65btb1-16dt aj65btb2-16dt dc dc aj65btb2-16dr dc positive common

analog modules connector type analog input modules analog output modules one-touch connector type one-touch connector type aj65vbtcu-68advn aj65vbtcu-68adin aj65vbtcu-68davn voltage input module model aj65vbtcu-68advn voltage output module number of channels number of occupied points 8 1/3 1 station type remote device model aj65vbtcu-68davn number of channels number of occupied points 8 1/3 1 station type remote device current input module model aj65vbtcu-68adin number of channels number of occupied points 8 1/3 1 station type remote device 1 three stations are occupied in ver 1 mode or one station is occupied in ver 2 mode terminal block type analog input modules analog output modules screw terminal block type screw terminal block type aj65sbt-64ad aj65sbt2b-64ad aj65sbt-62da aj65sbt2b-64da high accuracy high resolution high speed 2-piece terminal block type high resolution high speed 2-piece terminal block type voltage/current input module model aj65sbt-64ad aj65sbt2b-64ad

master/bridge modules melsec-q series qj61cl12 current consumption 130 ma 5 v dc supplied from programmable controller 28 ma 24 v dc supplied from power adapter current at start-up 70 ma 24 v dc supplied from power adapter weight 0.09 kg melsec-l series lj61cl12 current consumption 160 ma 5 v dc supplied from programmable controller 30 ma 24 v dc supplied from power adapter current at start-up 70 ma 24 v dc supplied from power adapter weight 0.12 kg melsec-fx3uc series melsec-fx series fx3uc-32mt-lt 2 fx2n-64cl-m current consumption 7 w main module only built-in power supply 24 v dc 350 ma for cc-link/lt network weight 0.25 kg cc-link/lt parameters for fx3uc-32mt-lt-2 can be configured with gx works2 gx developer or display modules cc-link to cc-link/lt bridge module current consumption 190 ma 5 v dc supplied from programmable controller 25 ma 2 v dc supplied from power adapter current at start-up 35 ma 24 v dc supplied from power adapter weight 0.15 kg configuration

cc-link ver.1.10 specifications control specifications item specifications remote i/o rx,ry maximum number of link points :2048 points each remote register rww :256 words remote register rwr :256 words remote i/o rx,ry number of link points per station :32 points each remote register rww :4 words remote register rwr :4 words transmission speed 10m/5m/2.5m/625k/156kbps communication method broadcast polling method synchronization method flag synchronous method encoding method nrzi method transmission path bus type conforms to eia rs-485 transmission format conforms to hdlc error control system crc x16 x12 x5 1 64 modules however the following conditions must be satisfied 1 x a 2 x b 3 x c 4 x d 64 a number of modules occupying 1 station b number of modules occupying 2 stations c number of modules occupying 3 stations d number of modules occupying 4 stations communication specifications number of connectable modules remote station number 16 x a 54 x b 88 x c 2304 a number of

cc-link partner association clpa actively promoting worldwide adoption of cc-link networks proactively supporting cc-link from promotion to specification development the cc-link partner association clpa was established to promote the worldwide adoption of the cc-link open-field network by conducting promotional activities such as organizing trade shows and seminars conducting conformance tests and providing catalogs brochures and website information clpa activities are successfully increasing the number of cc-link partner manufacturers and cc-link-compatible products as such clpa is playing a major role in the globalization of cc-link seminar trade show conformance testing lab visit the clpa website for the latest cc-link information url http www.cc-link.org 6f ozone front bldg 3-15-58 ozone kita-ku nagoya 462-0825 japan tel +81-52-919-1588 fax +81-52-916-8655 e-mail info@cc-link.org global influence of cc-link continues to spread cc-link is supported globally by clpa with offices

fa products plc melsec-q series universal model introducing the high-speed qcpu qnudvcpu for faster processing of large data volumes ◎realize high-speed high-accuracy machine control with various iq platform compatible controllers and multiple cpus ◎easily connect to gots and programming tools using built-in ethernet port ◎25 models from 10k steps small capacity to 1000k steps large capacity are available ◎seamless communication and flexible integration at any network level product specifications program capacity number of i/o points [x/y number of i/o device points [x/y basic instruction processing speed ld instruction external connection interface function module module extension style network plc 10k steps to 1000k steps 256 points to 4096 points/8192 points 120 ns to 1.9 ns usb all models equipped ethernet rs-232 memory card extended sram cassette i/o analog high-speed counter positioning simple motion temperature input temperature control