Page 105 of 176 ![]() |
![]() View extracted text
Page 105 of Circuit Breakers / Switches by Moeller Electric USA104 technical data circuit-breakers moeller sk1230-1157en-na rated uninterrupted current 160 a nzmb1 nzmn1 circuit-breakers disconnect switches up to 1200 a circuit-breakers rated impulse withstand voltage uimp main contacts auxiliary contacts rated operational voltage overvoltage category/pollution degree rated insulation voltage for use in it electrical power networks switching capacity rated short-circuit making capacity 240 v 50/60 hz 400/415 v 50/60 hz 440 v 50/60 hz 525 v 50/60 hz 690 v 50/60 hz ue ui v v v ac v v 6000 6000 690 iii/3 690 525 6000 6000 690 iii/3 690 690 icm icm icm icm icm ka ka ka ka ka 63 53 53 30 30 25 25 15 30 25 25 7.5 a 187 105 74 40 17 85 50 35 20 10 85 50 35 10 7.5 a rated short-circuit breaking capacity icn icu to iec/en 60947 operating sequence 240 v 50/60 hz icu ka o-t-co ka 400/415 v 50/60 hz icu ka 440 v 50/60 hz icu ka 525 v 50/60 hz icu 690 v 50/60 hz icu ka ics ka icu to iec/en 60947 operating sequence 240 v 50/60 hz o-t-co-t-co 400/415 v 50/60 hz ics ka ka 440 v 50/60 hz ics ka 525 v 50/60 hz ics ka 690 v 50/60 hz ics utilization category to iec/en 60947-2 rated short-time withstand current t 0.3 s icw ka ka t=1s icw rated making and breaking capacity rated operational current ac-1 400/415 v 50/60 hz ie a a 690 v 50/60 hz ie a ac-3 400/415 v 50/60 hz ie 690 v 50/60 hz ie a lifespan mechanical operations of which max 50 trip by shunt/undervoltage release maximum operating frequency ops/h lifespan electrical to iec/en 60947-4-1 section b ac-1 400/415 v 50/60 hz operations 690 v 50/60 hz operations ac-3 400/415 v 50/60 hz operations 690 v 50/60 hz operations w current heat loss per pole at i u overload releases temperature compensation for nzm2 to iec/en 60947 residual error in the range -25 °c 70 °c reference temperature 40 °c thermomagnetic k electronic total opening delay at short-circuit ms technical data divergent from the products for the iec market switching capacity na switches ul489 csa 22.2 no 5.1 240 v 60 hz 480v 60hz 600 v 60 hz notes 1 for 2 for 160 160 160 160 20000 120 10000 7500 7500 5000 13 160 160 160 160 20000 120 10000 7500 7500 5000 13 0.7 10 0.7 10 ka ka ka 35 252 85 352 switching capacity of na switches with nzm 1 na the following applies 480y/277 v from 60 a rated operational current ac-3 at nzm4 the following applies 400 v max 650 kw 600 v max 600 kw 3 for switching capacity of na switches with nzmh2 and nzmh3 the following applies current limiting switch to ul489 4 for switching capacity of na switches with nzmh4 at 240 v 60 hz the following applies please enquire[close] |
Page 105 of 176 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |