18 results for en 60947 found in 0.081 seconds

 

Catalog: Contactors and Motor Protection
Company/Brand: Moeller Electric USA


 

tolerance beyond that specified by iec/en 60947 this accommodates a range of -30 ... are the same frame size throughout the entire range the reduced size means smaller dc ...


 

and dil em contactors carry ul csa iec/en 60947 and vde 0660 approvals they are ...


 

dilm7 general standards ul csa iec/en 60947 vde 0660 lifespan mechanical ac ... iec 60068-2-30 ambient temperature open enclosed storage dilm9 dilm12 dilm17 dilm25 ... dc 180° mechanical shock resistance iec/en 60068-2-27 half-sinusoidal shock 10 ms ...


 

[v ac making capacity cos to iec/en 60947 up to 609 v [a breaking capacity 220/ ...


 

[w [w df [ms [ms [ms [ms [ms to en 60947-1 to en 60947-1 at 24 v 0.7 ­ 1.3 without ...


 

v 0.5 at 24 v 100 25 25 60 20 10 to en 60947-1 to en 60947-1 0.8 ­ 1.1 0.3 ­ 0 ...


 

dilm185 general standards ul csa iec/en 60947 vde 0660 lifespan mechanical ac ... iec 60068-2-30 ambient temperature open enclosed storage dilm225 dilm250 ops ops ops/h ... mechanical shock resistance iec/en 60068-2-27 half-sinusoidal shock 10 ms ...


 

the contacts making capacity cos to iec/en 60947 up to 690 v breaking capacity ...


 

the contacts making capacity cos to iec/en 60947 breaking capacity 220/230 v 380/ ... 60 hz open at 40° c at 50° c at 55° c enclosed conventional free air thermal current 1 ... -pole open enclosed ac-3 operation 220/230 v rated ...


 

standards ambient temperature open enclosed dil0mk dil1mk ul csa iec/en 60947 vde ... 230 v open 400 v 525 v 690 v 230 v enclosed 400 v 525 v 690 v making capacity i- ...


 

phase failure sensitive to iec/en 60947 manual automatic reset button built-in ...


 

phase failure sensitive to iec/en 60947 manual automatic reset button built-in ...


 

phase failure sensitive to iec/en 60947 manual automatic reset button built-in ...


 

phase failure sensitive to iec/en 60947 manual automatic reset button built-in ...


 

proofing ambient temperature open enclosed temperature compensation mounting ... 50 °c -13/122°f -25/40 °c -13/104°f iec/en 60947 vde 0660 ul csa damp heat ... temperature operating range to iec/en 60947 ptb -5 °c to +50 °c 23 °f to 122 °f ...


 

proofing ambient temperature open enclosed storage temperature compensation ... finger and back-of-hand proof [a iec/en 60947 vde 0660 ul csa damp heat ... temperature operating range to iec/en 60947 ptb -5 °c to +50 °c 23 °f to 122 °f ... sensor ambient temperature open and enclosed limited readability of the ldc display ...


 

proofing ambient temperature open enclosed storage temperature compensation ... from front [°c [°f [°c [°f [°c [°f iec/en 60947 vde 0660 ul csa damp heat ... temperature operating range to iec/en 60947 ptb -5 °c to +50 °c 23 °f to 122 °f ...


 

proofing ambient temperature open enclosed storage mounting position weight ... between contacts and supply voltage iec/en 60947 vde 0660 ul csa ptb 02 atex 3162 ...


 
  Similar searches   en 60947 (56)
en 60947 2 (54)
en 110 (275)
vulcan 500 en (17)
en 837 1 (14)
switch box 60947 (7)



Home | Latest catalogs | Contact