Page 41 of 101 ![]() |
![]() View extracted text
Page 41 of Contactors and Motor Protection by Moeller Electric USAtechnicaldata dilm7 dilm150 contactors dilm7 general main cable connection screw/bolt tightening torque control circuit cable cross-sections solid flexible with ferrule solid or stranded control circuit cable connection screw/bolt tightening torque tools main cable pozidriv screwdriver standard screwdriver control pozidriv screwdriver circuit cable standard screwdriver [nm [mm2 [mm2 [awg [nm [size [mm [size [mm m3.5 1.2 1 x 0.754.0 2 x 0.752.5 1 x 0.752.5 2 x 0.752.5 18 14 m3.5 1.2 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 dilm9 m3.5 1.2 1 x 0.754.0 2 x 0.752.5 1 x 0.752.5 2 x 0.752.5 18 14 m3.5 1.2 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 dilm12 m3.5 1.2 1 x 0.754.0 2 x 0.752.5 1 x 0.752.5 2 x 0.752.5 18 14 m3.5 1.2 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 dilm17 m5 3 1 x 0.75 4 1 x 0.75 4 1 x 0.752.5 2 x 0.752.5 18 14 m3.5 1.2 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 dilm25 m5 3 1 x 0.75 4 1 x 0.75 4 1 x 0.752.5 2 x 0.752.5 18 14 m3.5 1.2 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 dilm32 m5 3 1 x 0.75 4 1 x 0.75 4 1 x 0.752.5 2 x 0.752.5 18 14 m3.5 1.2 2 0.8 x 5.5 1x6 2 0.8 x 5.5 1x6 springloaded terminal connection 1 or 2 conductors can be connected main cable cross-section solid [mm2 flexible [mm2 flexible with ferrule [mm2 solid or stranded [awg control circuit cable cross-sections solid [mm2 flexible [mm2 flexible with ferrule [mm2 solid or stranded [awg tools wire strip length [mm screwdriver blade width [mm main contacts rated impulse withstand uimp [v ac overvoltage category/pollution degree rated insulation [v ac ui rated operational [v ac ue safe isolation to vde 0106 part 101 and part 101/a1 between coil and contacts [v ac between the contacts [v ac making capacity cos to iec/en 60947 up to 609 v [a breaking capacity 220/230 v [a 380/400 v [a 500 v [a 660/690 v [a 1000 v [a component lifespan ac-1 400 v [x 106 ie maximum operating frequency ac-1 400 v [ops/h ie ac-3 400 v [ops/h ie ac-4 400 v [ops/h ie short-circuit rating 400 v 500 v [a short-circuit type 2 protection 690 v 690 v [a max fuse 1000 v 1000 v [a type 1 400 v 500 v [a 690 v 690 v [a 1000 v 1000 v [a 0.75 2.5 0.75 2.5 0.75 2.5 18 14 0.75 2.5 0.75 2.5 0.75 2.5 18 14 10 3.5 8000 iii/3 690 690 400 400 112 70 70 50 40 1 800 1000 300 20 16 35 20 0.75 2.5 0.75 2.5 0.75 2.5 18 14 0.75 2.5 0.75 2.5 0.75 2.5 18 14 10 3.5 8000 iii/3 690 690 400 400 112 90 90 70 50 1 800 1000 300 20 16 35 20 0.75 2.5 0.75 2.5 0.75 2.5 18 14 0.75 2.5 0.75 2.5 0.75 2.5 18 14 10 3.5 8000 iii/3 690 690 400 400 144 120 120 100 70 1 800 1000 300 20 20 35 25 0.75 2.5 0.75 2.5 0.75 2.5 18 14 10 3.5 8000 iii/3 690 690 440 440 238 170 170 170 120 1 800 800 300 25 25 63 50 0.75 2.5 0.75 2.5 0.75 2.5 18 14 10 3.5 8000 iii/3 690 690 440 440 350 250 250 250 150 1 800 800 300 35 35 100 50 0.75 2.5 0.75 2.5 0.75 2.5 18 14 10 3.5 8000 iii/3 690 690 440 440 384 320 320 320 180 1 800 800 300 63 35 125 63 0[close] |
Page 41 of 101 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |