Contactors and Motor Protection [Entire catalog in thumbnail view]Contactors and Motor Protection [6 pages in thumbnail view]Contactors and Motor Protection [Page in normal view]Contactors and Motor Protection [Page in fullsize view]            Contactors and Motor Protection [First page]    Contactors and Motor Protection [Previous page]    Page 45 of 101    Contactors and Motor Protection [Next page]    Contactors and Motor Protection [Last page]            Contactors and Motor Protection catalog view Downloadable PDF catalog Contactors and Motor Protection Flash page flip catalog Contactors and Motor Protection Visitor statistics of Contactors and Motor Protection
Zoom in
View extracted text

Page 45 of Contactors and Motor Protection by Moeller Electric USA

technicaldata dilm7 ­ dilm150 contactors dilm7 current heat loss 3-pole current heat loss at ith current heat loss at ie to ac-3 400 v impedance per pole magnet systems pick-up and drop-out values ac [w [w [m 4.7 0.37 2.5 dilm9 4.7 0.6 2.5 dilm12 4.7 1.1 2.5 dilm17 7.3 1.7 2 dilm25 9.6 3.8 2 dilm32 12.1 6.1 2 pick-up drop-out dc pick-up drop-out power consumption of the coil at cold state and 1.0 x uc ac pick-up single-voltage coil 50 hz 60 hz 60 hz 50/60 hz sealing pick-up sealing pick-up [x uc [x uc [x uc [x uc [va [w [va [w [va [w [va [w [va [w 0.8 ­ 1.1 0.3 ­ 0.6 0.8 ­ 1.1 0.15 ­ 0.6 24 19 4 1.2 29 23 4.4 1.3 28 26 22 21 4.6 3.9 1.4 1.2 3 3 100 20 15 35 15 10 0.8 ­ 1.1 0.2 ­ 0.6 0.8 ­ 1.1 0.15 ­ 0.6 24 19 4 1.2 29 23 4.4 1.3 28 26 22 21 4.6 3.9 1.4 1.2 3 3 100 20 15 35 15 10 0.8 ­ 1.1 0.3 ­ 0.6 0.8 ­ 1.1 0.15 ­ 0.6 24 19 4 1.2 29 23 4.4 1.3 28 26 22 21 4.6 3.9 1.4 1.2 4.5 4.5 100 20 15 35 15 10 0.8 ­ 1.1 0.3 ­ 0.6 0.7 ­ 1.2 0.15 ­ 0.6 50 40 8 2.4 62 50 9.1 2.7 60 54 48 43 9.5 7.9 2.8 2.4 12 at 24 v 0.5 at 24 v 100 25 20 55 15 10 0.8 ­ 1.1 0.3 ­ 0.6 0.7 ­ 1.2 0.15 ­ 0.6 50 40 8 2.4 62 50 9.1 2.7 60 54 48 43 9.5 7.9 2.8 2.4 12 at 24 v 0.5 at 24 v 100 25 20 55 15 10 0.8 ­ 1.1 0.3 ­ 0.6 0.7 ­ 1.2 0.15 ­ 0.6 50 40 8 2.4 62 50 9.1 2.7 60 54 48 43 9.5 7.9 2.8 2.4 12 at 24 v 0.5 at 24 v 100 25 20 55 15 10 50/60 hz sealing [va [w dc operated pick-up sealing duty factor switching times at 100 uc approximate values main contacts ac closing delay opening delay dc closing delay opening delay arcing time electromagnetic compatibility emc emitted interference noise immunity [w [w df [ms [ms [ms [ms [ms to en 60947-1 to en 60947-1 at 24 v 0.7 ­ 1.3 without additional auxiliary contact modules and ambient temperature 40° c rdc 24 umin 24 v dc/umax 27 v dc rdc 60 umin 48 v dc/umax 60 v dc rdc 130 umin 110 v dc/umax 130 v dc rdc 240 umin 200 v dc/umax 240 v dc example uc 0.7 x umin ­ 1.2 x umax uc 0.7 x 24 v ­ 1.2 x 27 v dc

[close]
Contactors and Motor Protection [Entire catalog in thumbnail view]Contactors and Motor Protection [6 pages in thumbnail view]Contactors and Motor Protection [Page in normal view]Contactors and Motor Protection [Page in fullsize view]            Contactors and Motor Protection [First page]    Contactors and Motor Protection [Previous page]    Page 45 of 101    Contactors and Motor Protection [Next page]    Contactors and Motor Protection [Last page]            Contactors and Motor Protection catalog view Downloadable PDF catalog Contactors and Motor Protection Flash page flip catalog Contactors and Motor Protection Visitor statistics of Contactors and Motor Protection



All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA.


Home | Latest catalogs | Contact

© 2006-2008 by who-sells-it.com