Contactors and Motor Protection [Entire catalog in thumbnail view]Contactors and Motor Protection [6 pages in thumbnail view]Contactors and Motor Protection [Page in normal view]Contactors and Motor Protection [Page in fullsize view]            Contactors and Motor Protection [First page]    Contactors and Motor Protection [Previous page]    Page 53 of 101    Contactors and Motor Protection [Next page]    Contactors and Motor Protection [Last page]            Contactors and Motor Protection catalog view Downloadable PDF catalog Contactors and Motor Protection Flash page flip catalog Contactors and Motor Protection Visitor statistics of Contactors and Motor Protection
Zoom in
View extracted text

Page 53 of Contactors and Motor Protection by Moeller Electric USA

technicaldata dilm185 ­ dilm1000 contactors dilm185 dc rated operational current open dc-1 60 v 110 v 220 v 440 v 60 v 110 v 220 v 60 v 110 v 220 v dilm225 300 300 300 11 300 300 300 300 300 300 108 55 dilm250 300 300 300 11 300 300 300 300 300 300 95 48 dc-3 dc-5 current heat loss 3-pole current heat loss at ith current heat loss at ie to ac-3 400 v magnet systems voltage tolerance power consumption of the coil at cold state and 1.0 x uc ie ie ie ie ie ie ie ie ie ie [a [a [a [a [a [a [a [a [a [a [w [w 300 300 300 11 300 300 300 300 300 300 79 36 dilm comfort series dilm comfort series dilm comfort series pick-up drop-out pick-up sealing closing delay opening delay voltage interruptions reaction in marginal and transition 0 ­ 0.2 x uc min 10 ms range comfort series 0 ­ 0.2 x uc min 10 ms voltage dips 0.2 ­ 0.6 x uc min 12 ms 0.2 ­ 0.6 x uc min 12 ms 0.6 ­ 0.7 x uc min excess voltage 1.15 ­ 1.3 x uc max 1.3 x uc max 3 s 1.3 x uc max 3 s pick-up phase 0 ­ 0.7 x uc min 0.7 x uc min ­ 1.15 x uc max 1.15 x uc max permissible contact resistance of the external command device with actuation of a11 permissible residual current with actuation of a11 by the electronics with 0 signal sps signal level a3 ­ a4 to iec/en 61131-2 type 2 high low electromagnetic compatibility emc duty factor switching times at 100 uc approximate values main contacts dilm comfort series [x uc [x uc [va [w [va [w df [ms [ms 0.7 x uc min ­ 1.15 x uc max 0.2 x uc min ­ 0.6 x uc max 250 250 250 200 200 200 4.3 4.3 4.3 3.3 3.3 3.3 100 100 100 100 100 80 80 time is bridged successfully drop-out of the contactor time is bridged successfully drop-out of the contactor contactor remains switched on contactor remains switched on contactor remains switched on drop-out of the contactor contactor does not switch on contactor switches on with certainty contactor switches on with certainty 500 500 500 1 1 1 15 15 15 5 5 5 this product is designed for operation in industrial environments environment 2 usage in domestic areas environment 1 can cause radio frequency interence rfi so that additional interference to noise suppression measures must be provided 100 80 [m [ma [v [v uc min uc max ­ please see page 29 control transformer with uk 6%

[close]
Contactors and Motor Protection [Entire catalog in thumbnail view]Contactors and Motor Protection [6 pages in thumbnail view]Contactors and Motor Protection [Page in normal view]Contactors and Motor Protection [Page in fullsize view]            Contactors and Motor Protection [First page]    Contactors and Motor Protection [Previous page]    Page 53 of 101    Contactors and Motor Protection [Next page]    Contactors and Motor Protection [Last page]            Contactors and Motor Protection catalog view Downloadable PDF catalog Contactors and Motor Protection Flash page flip catalog Contactors and Motor Protection Visitor statistics of Contactors and Motor Protection



All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA.


Home | Latest catalogs | Contact

© 2006-2008 by who-sells-it.com