Page 9 of 101 ![]() |
![]() View extracted text
Page 9 of Contactors and Motor Protection by Moeller Electric USAcontactors ac dc coil heavy duty contactors for demanding applications all contactors in this range feature electronically controlled magnet direct connection to plcs and low level input devices large hp devices from dilm580 are vacuum contactors which built-in suppressor circuit for control protection increase electrical lifespan and decrease space requirements systems that dramatically reduces pick-up seal-in while increasing control voltage tolerance three-pole contactors with 110 to 250v ac or dc electronic coil 185 to 1000 amps ie [a ac-3 185 225 250 300 400 500 580 650 750 820 1000 maximum ratings for three phase motors kw ul csa hp ac-3 three phase 220 v 380 v 660 v 230 v 400 v 690 v 1000v 200 v 230 v 460 v 575 v 55 70 75 90 125 155 185 205 240 260 315 90 110 132 160 200 250 315 355 400 450 560 175 215 240 286 344 344 560 630 720 750 1000 108 108 108 132 132 132 600 600 800 800 1000 50 60 75 100 125 150 200 200 250 290 60 75 100 125 150 200 200 250 300 350 400 125 150 200 250 300 400 400 500 600 700 800 150 200 250 300 400 500 600 600 700 860 1000 auxiliary contacts no 2 2 2 2 2 2 2 2 2 2 2 400v ac-1 275 315 350 400 500 700 800 850 900 1000 1000 nc 2 2 2 2 2 2 2 2 2 2 2 type dilm185/22ra250 dilm225/22ra250 dilm250/22ra250 dilm300/22ra250 dilm400/22ra250 dilm500/22ra250 dilm580/22ra250 dilm650/22ra250 dilm750/22ra250 dilm820/22ra250 dilm1000/22ra250 article number 208193 208197 208201 208205 208209 208213 208216 208219 208222 208225 267214 price see green pages application notes conventional a1/a2 are applied to voltage in the usual manner l1 n a10 a11 a2 a1 a10 a11 a2 a1 a10 a11 a2 a1 a 24 v output from the plc can be connected directly to connections a3/a4 l1 n direct from the plc from low-consumption command devices command devices which can only be subject to minimal loads such as circuit board relays control circuit devices or position switches can be connected directly to a10/a11 l1 n a3 a4 a3 a4 a3 a4 24 v gnd ordering instructions locate the desired contactor 1 order using the type article number 2 see page 24 for a different coil voltage 3 see pages 15 22 for auxiliaries accessories 4 wide range coil 110 250 v 40-60hz ac dc 660v 690v or 1000v do not reverse directly when operating with frequency inverters or when performing a high-voltage test the suppressor on the load side must be removed standstill in an emergency emergency stop[close] |
Page 9 of 101 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |