Page 92 of 101 ![]() |
![]() View extracted text
Page 92 of Contactors and Motor Protection by Moeller Electric USAoverloadrelays technical data electronic zev electronic zev general standards climatic proofing ambient temperature open enclosed storage temperature compensation mounting position weight mechanical shock resistance half-sinusoidal shock 10ms degree of protection protection against direct contact when actuated from front -25/60 °c -13/140°f -25/40 °c -13/104°f 40 80 °c 104176°f continuous as required [kg see page 0.20 [g 15 ip20 finger and back-of-hand proof [a iec/en 60947 vde 0660 ul csa damp heat constant to iec 60068-2-78 damp heat cyclic to iec 60068-2-30 [°c [°f [°c [°f [°c [°f auxiliary and control circuit connectionscontinued auxiliary circuit rated insulation voltage ui [v ac [v ac [v ac [a 250 240 240 6 rated operational voltage ue safe isolation to vde 0106 part 101 and part 101/a1 between the auxiliary contacts conventional thermal current rated operational current ac-15 make contact ith 120 v 240 v 415 v 500 v break contact 120 v 240 v 415 v 500 v ie ie ie ie ie ie ie ie ie ie ie ie p max [a [a [a [a [a [a [a [a [a [a [a [a [w [a gg/gl [x uc [x uc [v ac/dc [ac [dc 3 3 3 3 1 2.5 6 0.85 1.1 0.85 1.1 600 300 b600 same polarity b300 opposite polarity r300 1500 2720 3680 1500 1650 see page 92 5 k under response temperature immediate main contacts overload relay setting range short-circuit protection rating maximum fuse terminal screw tightening torque tools pozidriv screwdriver standard screwdriver rated impulse withstand voltage overvoltage category pollution degree terminal capacity solid flexible with ferrule solid or stranded terminal screw tightening torque tools pozidriv screwdriver standard screwdriver 1 820 with overload relay in conjunction with a transformer as required for the contactor m3.5 0.8 1 0.8 x 5.5 4000 iii/3 1 x 0.5 2.5 2 x 0.5 1.5 1 x 0.5 2.5 2 x 0.5 1.5 1 x 18 14 m3.5 0.8 1 0.8 x 5.5 dc-13 l/r 15 ms 24 v 60 v 110 v 220 v power consumption short-circuit rating without welding max fuse pick-up and drop-out values ac operated dc operated [nm [size [mm auxiliary and control circuit connections uimp [v ul csa rated voltage pilot duty [mm2 [mm 2 thermistor protection total resistance cold response value reset range recovery time overload thermistor tripping ground-fault protection [awg [nm [size [mm ambient temperature operating range to iec/en 60947 ptb -5 °c to +50 °c 23 °f to 122 °f rated operational current making and breaking conditions to dc-13 l/r constant as stated see overlay fuses for short-circuit rating time/current characteristic terminal capacities auxiliary and control circuits solid flexible with ferrules with connection of conductors only the following combinations are permissible 0.5 and 0.75mm2 0.75 and 1 mm2 1 and 1.5 mm2 safe isolation up to 240 v depending on contact assignment between mains and outputs no potential isolation to thermistor and summation current transformer input and current sensor neighboring contacts us 127 v rated operational current ac-15 contacts 95/96 and 97/98 3 a contactor control contacts 05/06 and 07/08 1.5 a auxiliary contacts overload relay main contact setting range setting range dependant on current sensor ambient temperature open and enclosed limited readability of the ldc display at -15 °c 5 °f 93[close] |
Page 92 of 101 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |