moeller hpl0211-2003/2004 4/3 system overview easy control relay ... dc operated power supply ac 100 115 ­ 240 v 50/60 hz dc 24 v dc da 12 v dc 8 ... digital inputs 2 inputs usable as analog inputs [dc/da ... versions only 4 relay outputs max 10 a 4 transistor outputs lcd display x ... and snap fitting screw terminals a page 4/5 expansion device i/o expansion ac or ... dc operated power supply ac 100 ­ 240 v 50/60 hz dc 24 v dc 12 digital inputs ... and snap fitting screw terminals a page 4/9 expansion device easy202-re output ... expansion 2 relay outputs max 10 a screw fixing and ... snap fitting screw terminals a page 4/9 coupling unit a page 4/9 connection ... cable e.g nym 3 x 1.5 mm2 networking bus interfaces ...


 

4/8 moeller hpl0211-2003/2004 easy control relays mfd-titan expansion ... interface module graphical display 132 x 64 pixels switchable backlight freely ... removable titan front frame nema 4x ip65 mfd-80 265250 1 off nema 3r 12 ... ip65 illuminated keypad with 4 cursor buttons 4 function buttons 1 ... .net control module/cpu power supply 24 v dc ip20 cage clamp terminals serial ... cage clamp terminals 12 digital inputs 4 inputs available as analog inputs 4 ... relay outputs 12 digital inputs 4 inputs available as analog inputs 4 ... transistor outputs 12 digital inputs 4 inputs available as analog inputs 4 ... 1 analog output 12 digital inputs 4 inputs available as analog inputs 4 ... time clock only for appropriate devices 200 180 160 140 120 100 80 60 40 20 0 25°c ...


 

4/10 moeller hpl0211-2003/2004 easy control relays networking ... per easy6 · 3 brackets per easy8 · 2 brackets per easy2 · 3 brackets per ... · rated input voltage 50/60 hz 115/230 v · rated output voltage 24 v/12 v · ... rated output current 0.25 a/20 a · rated input voltage 50/60 hz 115/ ... 230 v ac · rated output voltage residual ... ripple 24 v dc g 3 · rated output current 1.25 ... length 0.8 m length 1.5 m data cable · 4-wire · 4 x 0.14 mm2 twisted pair awg 26 · ... to astm-d 635/72 une 53315-75 une 20672/83 2-1 and iec-695-2-1 · degree of ... ip65 to iec-144 and 525 · 94 mm x 77 mm x 25 mm 4 space units · 130 mm x ... 77 mm x 25 mm 6 space units zb4-101-gf1 061360 9 ...


 

moeller hpl0211-2003/2004 4/11 easy control relays documentation ... for inspection flap window · 12 mm x 66 mm x 82 mm · mounting on inspection ... window with front mounting units skf-ha 233782 2 off profibus-dp bus connector plug · ... cable entry suitable for easy204-dp zb4-209-ds2 206982 zb4-209-ds3 217820 1 off 1 off ... profibus dp data cable · 2-wire · 2 x 0.64 mm2 twisted · length 100 m ... -function display can be rotated by 4 x 90° sealing facility for protection ... use in the food industry zb4-900-kb1 206983 100 off mfd-xs-80 265259 1 off mfd-xm- ... 80 265258 1 off connection cable for connecting ... to easy800 or mfd-titan to mfd-titan 2 m long made up 5 m long can be prepared ...


 

-re general standards dimensions w xhxd weight mounting terminal capacities ... humidity non-condensing iec/en 60068-2-30 air pressure operation corrosion ... resistance iec/en 60068-2-42 iec/en 60068-2-43 ambient conditions ... iec/en 60529 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ... 60068-2-27 semi-sinusoidal 15 g/11 ms drop to iec/ ... en 60068-2-31 free fall packaged iec/en 60068-2-32 ... electrostatic discharge iec/en 61000-4-2 level 3 esd air discharge contact ... electromagnetic fields iec/en 61000-4-3 rfi radio interference suppression en ... 55011 burst pulses iec/en 61000-4-4 level 3 supply cables signal lines high ... -energy pulses surge iec/en 61000-4-5 high-energy pulses surge iec/en 61000-4 ...


 

easy6 general standards dimensions w xhxd weight mounting terminal capacities ... humidity non-condensing iec/en 60068-2-30 air pressure operation corrosion ... resistance iec/en 60068-2-42 iec/en 60068-2-43 ambient conditions ... iec/en 60529 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ... 60068-2-27 semi-sinusoidal 15 g/11 ms drop to iec/ ... en 60068-2-31 free fall packaged iec/en 60068-2-32 ... electrostatic discharge iec/en 61000-4-2 level 3 esd air discharge contact ... electromagnetic fields iec/en 61000-4-3 rfi radio interference suppression en ... 55011 burst pulses iec/en 61000-4-4 level 3 supply cables signal lines high ... -energy pulses surge iec/en 61000-4-5 high-energy pulses surge iec/en 61000-4 ...


 

input current at 115/120 v ac 60 hz at 230/240 v ac 50 hz voltage dips iec/en ... 61131-2 power loss at 115/120 v ac at 115/230 v ... ac 100/110/115/120/230/240 ac 10 15 90 ­ 264 50x60 g 5 ... normally 40 normally 20 20 normally 5 normally 5 easy412-ac 100/ ... 110/115/120/230/240 ac 10 15 85 ­ 264 50x60 g 5 ­ normally 35 20 normally 10 ... 10 easy618/619-ac-r 100/110/115/120/230/240 ac 10 15 85 ­ 264 50x60 g 5 ... normally 70 normally 35 20 normally 10 normally 10 easy8 ac-r ... digital inputs 115/230 v ac number status indication potential ... no yes yes v ac v ac hz ma ma ma ma 0 ­ 40 79 ­ 264 50 ­ 60 ­ 6 x 0.25 at 115 v ac ... 60 hz 6 x 0.5 at 230 v ac 50 hz ­ 2 x 4 at 115 v ac 60 hz 2 x 6 at 230 v ac 50 ...


 

two contacts making capacity ac-15 250 v ac 3 a 600 ops h dc-13 l/r f 150 ms ... 24 v dc 1 a 500 ops h breaking capacity ac ... -15 250 v ac 3 a 600 ops h dc-13 l/r f 150 ms ... 24 v dc 1 a 500 ops h filament bulb load ... 1000 w at 230/240 v ac 500 w at 115/120 v ac fluorescent ... lamp load fluorescent lamp load 10 x 58 w at 230/240 v ac with upstream ... uncompensated fluorescent lamp load 1 x 58 w at 230/240 v ac conventional ... load ul/csa uninterrupted current at 240 v ac uninterrupted current at 24 v dc ... notes easy202-re operations v ac v ac x 106 a ma a a kv v ac v ac v ac v ac yes ... 300 600 10 8 500 16 16 6 250 250 300 300 300000 200000 300000 200000 ... 25000 25000 yes 300 600 10 8 500 16 16 6 250 250 ...


 

20 technical data moeller sk2528-1125gb- ... suppressor circuit 1 t0.95 1 ms r 48 o l 16 mh utilization factor duty ... .5 hz max df 50 dc13 t0.95 72 ms r 48 o l 1.15 h utilization factor duty ... f 0.5 hz max df 50 t0.95 15 ms r 48 o l 0.24 h utilization factor duty ... factor notes 8 ue ue v dc v dc ma ma 24 20.4 ­ 28.8 f5 18 ­ 32 24 ­ 44 yes ... ma v v max 0.5 3 q1 ­ q4 5 q5 ­ q8 0.1 2.5 u ue -1 v yes electronic q1 ­ q4 ... diagnostics input i16 i15 0.7 f ie f 2 16 32 yes 40000 steuerrelais easy ... a a ops h max a group 1 q1 to q4 group 2 q5 to q8 4 2 lcd display if provided g ... df operations 0.25 100 1500 g df operations 0.25 100 1500 ... g df operations 0.25 100 1500 g df operations 1 100 ...


 

22 technical data moeller sk2528-1125gb- ... -dp steuerrelais easy dimensions w xhxd weight mounting terminal capacities ... humidity non-condensing iec/en 60068-2-30 air pressure operation corrosion ... resistance iec/en 60068-2-42 iec/en 60068-2-43 ambient conditions ... iec/en 60529 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ... 60068-2-27 semi-sinusoidal 15 g/11 ms drop to iec/ ... en 60068-2-31 free fall packaged iec/en 60068-2-32 ... electrostatic discharge iec/en 61000-4-2 level 3 esd air discharge contact ... electromagnetic fields iec/en 61000-4-3 rfi radio interference suppression en ... 55011 burst pulses iec/en 61000-4-4 level 3 as-interface cables supply ... high-energy pulses surge iec/en 61000-4-5 level 2 immunity to line-conducted ...


 

24 technical data moeller sk2528-1125gb- ... -co general standards dimensions w xhxd weight mounting terminal capacities ... humidity non-condensing iec/en 60068-2-30 air pressure operation corrosion ... resistance iec/en 60947-2-42 iec/en 60947-2-43 ambient conditions ... iec/en 60529 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ... 60068-2-27 semi-sinusoidal 15 g/11 ms drop to iec/ ... en 60068-2-31 free fall packaged iec/en 60068-2-32 ... electrostatic discharge iec/en 61000-4-2 level 3 esd air discharge contact ... electromagnetic fields iec/en 61000-4-3 rfi radio interference suppression en ... 55011 burst pulses iec/en 61000-4-4 level 3 supply cables signal lines high ... -energy pulses surge iec/en 61000-4-5 level 2 immunity to line-conducted ...


 

26 technical data moeller sk2528-1125gb- ... -pow general standards dimensions w xhxd weight mounting terminal capacities ... humidity non-condensing iec/en 60068-2-30 air pressure operation corrosion ... resistance iec/en 60947-2-42 iec/en 60947-2-43 max installation ... 60529 en 50178 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ... 60068-227 semi-sinusoidal 15 g/11 ms drop to iec/ ... en 60068-2-31 free fall packaged iec/en 60068-2-32 ... electrostatic discharge iec/en 61000-4-2 level 3 esd air discharge contact ... electromagnetic fields iec/en 61000-4-3 rfi radio interference suppression en ... 55011 burst pulses iec/en 61000-4-4 level 3 high-energy pulses surge iec/en ... 61000-4-5 high-energy pulses surge iec/en 61000-4 ...


 

28 technical data moeller sk2528-1125gb- ... -hci general standards dimensions w xhxd mounting channels voltage range at ue ... higher current 115/230 v ac extension of the switch off delay ... humidity non-condensing iec/en 60068-2-30 air pressure operation corrosion ... resistance iec/en 60947-2-42 iec/en 60947-2-43 ambient conditions ... iec/en 60529 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ... 60068-2-27 semi-sinusoidal 15 g/11 ms drop to iec/ ... en 60068-2-31 free fall packaged iec/en 60068-2-32 ... electrostatic discharge iec/en 61000-4-2 level 3 esd air discharge contact ... electromagnetic fields iec/en 61000-4-3 rfi radio interference suppression en ... high-energy pulses surge iec/en 61000-4-5 immunity to line-conducted interference ...


 

moeller sk2528-1125gb-int 29 technical data mfd-80 general ... standards dimensions w xhxd weight mounting mfd-cp8 kg terminal ... humidity non-condensing iec/en 60068-2-30 air pressure operation ambient ... iec/en 60529 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ... 60068-2-27 semi-sinusoidal 15 g/11 ms drop to iec/ ... en 60068-2-31 free fall packaged iec/en 60068-2-32 ... electrostatic discharge iec/en 61000-4-2 level 3 esd air discharge contact ... electromagnetic fields iec/en 61000-4-3 rfi radio interference suppression en ... 55011 burst pulses iec/en 61000-4-4 level 3 supply cables signal lines high ... -energy pulses surge iec/en 61000-4-5 high-energy pulses surge iec/en 61000-4 ... -5 level 2 immunity to line-conducted interference ...


 

mfd-t easy control relay dimensions w xhxd weight mounting terminal capacities ... ambient temperature mm kg en 61000-6-1 2 3 4 iec 60068-2-6 iec 60068-2-27 89 x ... 90 x 44 0.15 fitted into the power supply unit ... 0.75x2.5 awg 22 ­ 12 0.5x1.5 awg 22 ­ 12 3.5 x 0.6 en 61000-6-1 2 3 4 iec ... 60068-2-6 iec 60068-2-27 89 x 90 x 25 installed 0.14 fitted into the power ... supply unit 0.75x2.5 awg 22 ­ 12 0.5x1.5 awg 22 ­ 12 3.5 x 0.6 mm2 ... humidity non-condensing iec/en 60068-2-30 air pressure operation ambient ... iec/en 60529 vibrations iec/en 60068-2-6 constant amplitude 0.15 mm constant ... acceleration 2 g mechanical shock resistance iec/en ...


 

two contacts making capacity ac-15 250 v ac 3 a 600 ops h dc-13 l/r f 150 ms ... 24 v dc 1 a 500 ops h breaking capacity ac ... -15 250 v ac 3 a 600 ops h dc-13 l/r f 150 ms ... 24 v dc 1 a 500 ops h filament bulb load ... 1000 w at 230/240 v ac 500 w at 115/120 v ac fluorescent ... lamp load fluorescent lamp load 10 x 58 w at 230/240 v ac with upstream ... uncompensated fluorescent lamp load 1 x 58 w at 230/240 v ac conventional ... load ul/csa uninterrupted current at 240 v ac uninterrupted current at 24 v dc ... capacity at r 300 operations v ac v ac x 106 a ma a a kv v ac v ac v ac v ac yes ... yes 300 600 10 8 500 16 16 6 250 250 300 300 300000 200000 300000 200000 ... 25000 25000 ue ui operations operations operations ... operations operations operations 25000 25000 25000 x 106 hz hz hz a a 10 10 2 0.5 10 ...


 

potentiometer ip 54 10 k linear 0.25 w max dil et etr4-70 rr-10 031344 ... cs-te 095853 for panel mounting of etr 4 timing relays component labelling ... system clip-in label plate 8 x 10 mm dil kg10 1 022256 clips into 2- ... contact modules standard quantity 500 8 x 20 mm dil e dil er dil dil r kg20 1 ... 091075 clips into 4-pole auxiliary contact modules and basic ... 500 label plate with mounting stud 8 x 17,5 mm color white dil xgks-z 1 ... 207508 for use with moeller equipment with ... quantity 500 sheet of labels 7,5 x 17 mm color yellow hks 3 ral 1018 xgks- ... t kg 20 for inscription using laser printer ... printer plotter marker pen photocopier xgke-ge 2 207517 standard quantity pad of 25 ... sheets 240 labels persheet self-adhesive price per ...


 

r g-dil00m mounting rails 7,5 length 2 m 6 ½ ft dil e dil r etr 4 ts 35 x 7 ... mounting rail to en 50 022 35 ts 35 x 15 050657 15 24 the diagrams show the ... dil er-ac normally open 0 1,9 2,78 mm dil r normally open 0 4,3 5,7 mm 2,5 ... 5,7 mm normally closed 0 0,95 2,78 mm normally closed 0 dil er-dc normally ... open 0 1,9 2,85 mm 2,85 mm early make late break dil normally ... open 0 0 2,4 4 5,7 mm 5,7 mm normally closed 0 0,95 ... dil e normally open 0 1,9 2,78 mm 2,78 mm 0 5,6 3,9 7 mm 7 mm normally closed ... 0 0,89 tp 11 dil normally open 0 4,1 5,7 mm 5,7 mm d dil e early make 0 1, ... 06 1,86 1,9 2,88 mm 2,88 mm 2,78 mm 2,78 mm normally closed 0 1,7 late break 0 ... article no list price see price list 35 27 ...


 

ie rated operational current x 10 6 2000 20 10 5 1000 dil r ac-15 normally ... control relay electronic timing relay 2 1 0.5 ac-15 0.2 0.1 0.01 0.02 0.05 0.1 ... 0.2 0.5 1 2 5 10 a e 500 200 ac-15 240 v 100 0 1 2 3 4 5 6 7 8 9 10 a e 240 v ... ie rated operational current s/h 5000 x 10 6 2000 20 10 1000 5 2 1 dc-13 0.5 0. ... 2 0.1 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 a e 500 dc-13 200 220 v l r 100 0 ... 1 2 3 4 5 6 7 8 9 10a e 220 v l r 50 ms 50 ms dil r dc-131 ... rated operational current s/h 5000 106 2000 20 10 5 500 1000 2 1 dc-13 0.5 0.2 0.1 ... 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 a l r 24 v 50 ms dc-13 200 24 v l ... r 100 0 1 2 3 4 5 6 7 8 9 10a 50 ms le le notes 1 make ...


 

60 947 vde 0660 operations operations x106 x106 s/h 10 20 20 20 9000 7000 damp ... heat constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 50 -25 40 as required except vertical with a1/a2 ... at bottom -25 50 -25 40 as required except suspended min max ... contact module sinusoidal impulse 20 ms basic unit n.o n.c contact basic ... solid flexible with ferrule to din 46 228 solid or stranded terminal screw ... max size g g 10/8 10/8 ­ ­ g g ­ ­ ip 20 yes page 02/055 10/6 10/6 ip 20 dil r ... page 02/056 page 14/020 page 14/020 1 x 0.75 ­ 4 2 x 0.75 ­ 4 1 x 0.75 ­ 2.5 2 ... x 0.75 ­ 2.5 18 12 m3.5 2 0.8 x 5.5 1x6 1.2 kg kg mm2 mm2 mm2 mm2 awg ...


 

947 positively driven contacts to zh 1/457 including auxiliary contact module ... /3 690 600 300 yes 8000 iii/3 690 500 440 220/240 v 380/415 v 500 vaaa 6 41 3 21 ... 1,5 6 4 1,5 dc-132 above 110v and at l/r 15ms ... valves dc motors contacts in series 1 24 v 2 1 60 v 3 1 110 v 3 1 220 v l/r 50 ... solenoid brakes contacts in series 2 24 v 2 60 v 3 1 110 v 3 1 220 v control ... circuit reliability ue 24 v umin 17 v imin 5.4 ma fault ... current ith component lifespan ue 240 v ac-15 dc-13 l/r 50 ms >2 contacts ... welding max overcurrent protective 220/240 v device 380/415 v 220/230 v maximum ... pilot duty general use rating notes 2 aaaa 2,5 2,5 1,5 0,5 10 10 6 6 3 5 1 ...


 

60 hz pick-up pick-up pick-up pick-up x uc x uc x uc x uc 0,8 1,1 0,85 1,1 0, ... va/w va/w va/w w df ms ms ms ms ms ms 25/22 4,6/1,3 30/26 5,4/1,6 29/24 3,9/1,1 ... 2,6 100 14 ­ 21 8 ­ 18 45 26 ­ 35 15 ­ 25 70 67/52 8,5/2,5 ­ ­ ­ ­ 9,5 100 22 14 ...


 

mounting position v dil vs 1 dil vs 2 dil ets 4-vs 3 ul csa iec/en 60 947 vde ... 0660 x 106 x 106 ops h ops h 1 1 5 1 ­ 10 ­ 9000 ­ ... 1500 damp heat constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 50 -25 40 as required except suspended 1 10/6 ­ ... ip 00 yes page 02/056 0.08 -25 50 -25 40 as required min max min max °c °c -25 ... 50 -25 40 as required -25 60 -25 45 as required mechanical shock resistance ... sinusoidal shock 20ms n.o n.c contact mechanical latching ... solid flexible with ferrule to din 46 228 solid or stranded terminal screw ... screwdriver tightening torque notes 1 2 g g ­ 20 ip 00 page 02/056 0.1 10/­ ­ ... ip 00 page 02/056 0.04 vs 1 0.05 vs 2 1 x 0.75 ­ 4 2 x 0.75 ­ 4 1 x 0.75 ­ 2.5 2 ...


 

tpe 11 dil tpd 11 dil v dil vs 1 dil vs 2 dil ets 4-vs 3 industrial control ... 947 positively driven contacts to zh 1/457 including auxiliary contact module ... ue rated operational current ie ac-15 220/240 v 380/415 v dc-13 1 above 110v and ... valves dc motors contacts in series 1 24 v 1 60 v 1 110 v 1 220 v l/r 50 ms e.g ... solenoid brakes contact in series 1 24 v 1 60 v 1 110 v 1 220 v l/r 300 ms 1 ... 24 v 1 60 v 1 110 v 1 220 v control circuit reliability ue 24 v ... umin 17 v imin 5,4 ma fault probability conv thermal ... ith component lifespan at ie 0.1 a/1.2 a ac-15 230 v operations dc-13 230 v ... 1000va without welding max overcur 220/240 v rent protec 380/415 v tive device ... yes v v ac v ac a a 6000 iii/3 690 500 4 4 ­ 8000 iii/3 690 415 ­ ­ ­ 4000 iii/2 ...


 

50 hz dc operated v dil vs 1 dil vs 2 dil ets 4-vs 3 unlatching unlatching ... pick-up unlatching x uc x uc x uc x uc ­ ­ ­ ­ ­ ­ ­ 0,85 ­ 1,1 0,8 ­ 1,1 0 ... ,8 ­ 1,1 0,75 ­ 1,25 ­ ­ ­ 0,85 ­ 1,2 ­ pull-in sealing pull-in sealing va/w ... va/w w df ­ ­ ­ 100 13/12 5/2 26 100 at ac 200 ms at dc ­ ­ 35 25 45 25 ... ­ ­ ­ ­ ­ ­ 0,27 100 ­ ­ 0,6 100 closing delay opening ... ms ms ms ms ms ms ­ ­ ­ ­ ­ ­ 3 5 0,2 k 15 20 6 2,5 ­ ­ ­ ­ ­ ­ ­ ­ 7 3 ... to ambient temperature based on +20 °c long-time deviation recovery time ...


 

02/048 dil et etr 4 timing relays technical data dil et-a ... etr 4-a industrial control relays electronic ... shock resistance sinusoidal shock 20 ms degree of protection dimensions ... terminal capacity csa ul iec/en 60 255 vde 0435 iec/en 60 947 operations ... operations x 106 x 106 30 30 30 30 damp heat constant to ... iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 20 60 -20 45 as required 4 ip 20 page 02/056 0,09 page 02/040 as dil er ... 6000 iii/2 600 440 250 -25 60 -20 45 as required 4 ip 20 page 02/056 0,1 ... page 02/043 as ets 4 vs 3 6000 iii/3 600 440 250 min max min ... contacts making capacity ac-14 cos 0,3 440 v ac-15 cos 0,3 220 v dc-11 l/r 40 ms ...


 

data esr3-no-31 esr4-no-31 esr4-no-21 industrial control relays electronic ... -circuit current fuse pick-up v ac v dc x uc 230 ­ 0,85 ­ 1,1 24 24 0,85 ­ 1,1 24 ... 24 0,85 ­ 1,1 va/w w v dc v dc ma a 3,2/2,5 ­ 24 40 40 1 short-circuit ... protected transformer 2,4/1,4 1,3 24 ­ 40 1,4 ptc resistor 3,5/2,1 1,5 24 ­ 50 2, ... 2 ptc resistor response time recovery ... interference noise immunity ms ms ­ ­ 2000 3000 2000 3000 ma ms ms ms ms ms ms y13 ... y14 40 y12 y31 15 80 500 50/100 50 500 ­ y2 40 ... ­ 50 40 50 50 ­ s12 30 s31 s22 20 80 60 40/100 50 500 ­ to en 50 081-1 ... and en 50 081-2 to en 50 082-2 ...


 

ul/csa max hp rating 50/60hz 1 phase 4 115 v hp 230 v hp 3 phase 200 v hp 230 ... v hp 460 v hp 575 v hp article no see price list ... 120v coil 1 overload relay not included 2 list price magnetic contactors magnetic ... starters ½ 1 2 2 3 3 3 5 1½ 2 3 3 5 7½ 10 15 3 3 5 5 10 10 15 20 3 3 ... 7½ 7½ 10 15 20 25 5 7½ 10 15 20 25 40 50 7½ 10 15 20 25 30 40 50 dil00m/11/ ... z00 x/sm 100460 dil00am/11/z00 x/sm 100458 dil0m/11/z00 x/sm 100464 ... dil0am/11/z00 x/sm 100462 dil1m/11s/z1 x/sm 100467 dil1am/11s/z1 x/sm 100466 ... dil2m/11/z1 x/sm 100470 dil2am/11/z1 x/sm 100469 dil2am/11/z1-75/sm 3 100468 ... notes 1 2 3 4 for coil voltages other than 120v refer ...


 

03/032 system pkz 2-sp self-protected combination starters all ... fuses as per the intent of nec article 430 and cec rule 28 the self-protected ... or set of fuses is required the pkz 2/zm s-sp has two sets of main contacts ... rated to switch a motor load of 30hp at 460v 25 hp at 575v ac eleven plug-in trip ... fractional hp sizes through 30 hp at 460v and 25 hp at 575v ac as a result ... capable of delivering 65ka rms sym at 480y/277v ac and 42ka rms sym at 600y 347v ... in hard-to-fit areas exceeds iec type 2 coordination without the need for ... s-pkz2 contactors a page 08/024 1 2 3 4 5 6 7 8 9 10 11 12 13 both field wiring ... with 1 n.o and 1 n.c auxiliary contacts 2 n.o contacts are also available the ... magnetic trip dial range 8.5 14 x trip module rating adjustable thermal ...


 

shown in the alpha-numeric price list xk0211-2001/2002-cdn under full voltage starters ... standard 1-unit pushbutton standard 2-unit pushbutton standard 3-unit pushbutton ... or illuminated pushbutton 1 12 13 3r 4x 1 12 13 3r 4x all types all types all ... types 1 12 13 3r 4x 1 12 13 3r 4x 1 12 13 3r 4x all types added devices ... contact no charge type emt6 no charge 250v 1 or 2 fuses 600v 2 fuses unwired wired ... auxiliary relays control relay max of 4 poles timing relay terminal block wired ... price list 0am 1m 1am see price list 2m 2am see price list 3m80 4m115 2 speed 2 ... speed 3 x 1 description m185 m250 m300 see price ...


 

shown in the alpha-numeric price list xk0211-2001/2002-cdn under reduced voltage ... standard 1-unit pushbutton standard 2-unit pushbutton standard 3-unit pushbutton ... or illuminated pushbutton 1 12 13 3r 4x 1 12 13 3r 4x all types all types all ... types 1 12 13 3r 4x 1 12 13 3r 4x 1 12 13 3r 4x all types added devices ... circuit type emt6 no charge no charge 250v 1 or 2 fuses 600v 2 fuses unwired wired ... auxiliary relays control relay max of 4 poles timing relay terminal block wired ... meter nameplates special nameplates 3 x 1 description price adder to main ... price list 0am 1m 1am see price list 2m 2am see price list 3m80 4m115 m185 m250 ...


 

starters accessories dimensions width x height for use with type article no ... system 1 clip-in label plate 8 x 10 mm dil kg10 1 022256 clips into 2- ... contact modules standard quantity 500 8 x 20 mm dile diler dil dilr kg20 1 ... 091075 clips into 4-pole auxiliary contact modules and basic ... 500 label plate with mounting stud 8 x 17,5 mm color white dil xgks-z 1 ... 207508 sheet of labels 7,5 x 17 mm color yellow hks 3 qral 1018 xgks ... xgks-z kg 20 for inscription using laser printer ... plotter marker pen copier xgke-ge 2 207517 standard quantity pad of 25 sheets 240 ... plotter by phoenix contact or others 8 x 17,5 mm dil3m80 to dilm820 xgks-t 2 ... 207505 standard quantity 10 cards 40 labels per card universal mounting ...


 

outlined in appendix b of iec 60 947-4 are used by manufacturers to establish ... iec utilization categories e.g ac-3 ac-4 the iec 60 947 standard states that ... iec utilization categories ac-3 and ac-4 are most often encountered in contactor ... electrical characteristics make up to 6 x rated motor current break 1 x rated ... machines extreme switching duty ac-4 for squirrel-cage motors electrical ... characteristics make 6 x rated motor current break 6 x rated ... current utilization category 100 ac-4 determination of the maximum number of ... per hour type s/h 9000 6000 5000 4000 3000 ac-1 2 2 2 2 2 2 2 2 2 ac-3 1 1 1 ... 1 1 1 1 1 1 ac-2 ac-4 3 3 3 3 3 3 3 3 3 2000 1500 1000 800 600 500 400 300 200 150 ...


 

based on utilization categories at 460v 50/60hz ac-3 electrical characteristics ... make 6 x motor flc break 1 x motor flc normal switching duty 100 ac- ... a 3 phase motor flc at 50 60 hz ac-4 electrical characteristics extreme ... motor flc at 50 60 hz s-pkz2 notes 1 2 ac-3 and ac-4 lifespan values for ... dil3m80 and dil4m145 are determined at 400v ac apply a derating factor of 0.9 90 ... for corresponding 460v ac values for 600v ratings and larger ... contactors magnetic starters make 6 x motor flc break 6 x motor flc inching ... plugging 100 ac-4 ...


 

technical data dil em dc 12 v 24 v 60 v 110 v 220 v dc-3 12 v 24 v 60 v ... 110 v 220 v dc-5 12 v 24 v 60 v 110 v 220 v current heat loss 3 or 4 pole with ... thermal current ith with ie to ac-3/400 v magnet systems pick-up and drop-out ... frequency coil v 50/60 hz dc operated 2 power consumption of the coil ac ... 50 hz v 50/60 hz at 60 hz dc operated 2 pull-in sealing duty factor switching ... time at 690 v ac coil 50/60 hz notes 1 2 dil em4 dil em-g magnetic contactors ... starters dc-1 aaaaaaaaaaaaaaaww 20 20 20 20 20 8 8 4 3 ­ 2,5 2,5 2,5 1,5 0,3 2 0 ... ,5 ­ ­ ­ ­ ­ ­ ­ ­ ­ 1 ­ ­ ­ 2,5 1 2,7 ­ 20 20 20 20 20 8 8 4 3 ­ 2,5 2,5 2,5 ...


 

dil 0 m dil 0 am dil 1 m dil 1 am dil 2 m dil 2 am dil 3m 80 dil 4m 115 dil m ... 185 dil m 225 dil m 250 dil m 300 dil m 400 dil m 500 dil m 580 dil m 650 dil m 750 ... current ie open dc-1 to 60 v 110 v 220 v 440 v dc-3 to 60 v 110 v 220 v 440 v ... dc-5 to 60 v 110 v 220 v 440 v current heat loss 3 pole with conv ... thermal current ith with ie ac-3/400 v magnet systems pick-up and drop-out ... -out pick-up drop-out aaaaaaaaaaaaww 20 20 12 3 15 15 5 ­ 12 12 ­ ­ 20 20 15 3 20 ... 20 8 ­ ­ ­ ­ ­ ­ ­ 35 35 20 5 20 20 10 ­ 18 18 ­ ­ 3,7 0,7 25 55 55 40 7 28 ... 28 15 ­ 25 25 ­ ­ 27 27 90 90 80 10 70 70 45 ­ 45 45 ­ ­ 48 48 ...


 

dil 0 m dil 0 am dil 1 m dil 1 am dil 2 m dil 2 am dil 3m 80 dil contactors ... technical data dil 4m 115 dil m 185 dil m 225 dil m 250 dil m ... 300 dil m 400 dil m 500 dil m 580 dil m 650 dil m 750 ... sealing voltage interruptions 0 ­ 0,2 x us f 10 ms 0 ­ 0,2 x us 10 ms voltage ... drops 0,2 ­ 0,6 x us 0,2 ­ 0,6 x us 0,6 ­ 0,7 x us excess voltage 1,15 ... ­ 1,3 x us 1,3 x us 1,3 x us magnetic contactors magnetic ... starters ms ms ms ms ms ms 14 ­ 22 5 ­ 14 35 ­ 40 5 ­ 10 13 ­ 212 10 9 ­ ... 19 5 ­ 13 40 ­ 55 6 ­ 10 13 ­ 192 20 11 ­ 19 6 ­ 13 68 ­ 75 10 ­ 15 12 ­ 162 ... 20 14 ­ 22 5 ­ 15 75 ­ 90 12 ­ 18 13 ­ 192 20 20 ...


 

rated operational current ie ac-15 200/240 v 380/415 v 500 v 24 v dc-131 l/r 15ms ... 60 v 110 v 220 v conventional thermal current ith ... control circuit reliability at ue 24 v dc umin 17 v imin 5,4 ma fault ... probability hf component lifespan ue 230 v ac-15 3 a operations short-circuit ... rating without welding maximum fuse 2 max overcurrent protective device v v ... v ac aaaaaaaa sdilm 6000 iii/3 690 500 440 440 6 4 1,5 10 6 3 1 16 dil m 6000 iii ... /3 690 500 440 440 6 4 1,5 10 6 3 1 16 dil m 820-xhi 6000 iii ... /3 690 500 440 440 6 4 1,5 10 6 3 1 10 magnetic contactors ... 028 16 ­ dil r diagram a page 02/028 16 4 dil r diagram a page 02/028 16 4 220/ ... 230 v using faz-c paralleling links p1 dil ...


 

mini contactors dil em g 52 35 45 83 contactors dil 00 m g to dil 2 am g ... a5 a4 a c2 c3 c1 4,7 c dil a a1 a4 a5 b b1 b2 c without h ... mde mde b4 a2 a3 c6 12 00 m 00 am 00 m 4 45 35 ­ ­ 77 39 60 74 76,5 107 136 136 ... g g g 45 35 ­ ­ 77 39 60 99 101,5 132 161 161 0m ... 0 am 45 35 55 60 91 46 75 79 86,3 112 141 ­ g g 45 35 55 60 ... 91 46 75 104 113,3 137 166 ­ 1m 1 am 60 50 70 ... 80 98 49 75 97 ­ 130 159 ­ g g 60 50 70 80 98 ... 49 75 122 ­ 155 184 ­ 2m 2 am 70 60 80 90 118 59 90 102 ­ 135 164 ... 90 118 59 90 127 ­ 160 189 ­ b1 b3 b2 b 2 m4 × 16 dil 00 am dil 0 am 2 m5 × 16 ... dil 1 am dil 2 am 00 34 45 120 19 90 34 45 120 19 115 00 34 45 133 18 96 34 45 133 ...


 

relay tripping class class 5 10 15 20 can be selected tripping delay in s 10 ... load from cold setting current ie x3 11.3 22.6 34 45.3 x4 8 15.9 23.9 31.8 ... x5 6.1 12.3 18.4 24.6 x6 5 10 15 20 x 7.2 4.1 8.2 12.3 16.4 x8 3.6 7.3 10.9 14.6 ... x 10 2.9 5.7 8.6 11.5 operational readiness ... delay in minutes class 5 10 tready 5 6 25 30 35 40 56.6 39.8 30.7 25 20.5 18.2 14 ... .4 67.9 47.7 36.8 30 24.5 21.9 17.2 79.2 55.7 43 35 28.6 25.5 20.1 90.5 63.6 49. ... 1 40 32.7 29.2 23 15 7 20 8 25 9 30 10 35 11 40 12 tripping delay in s ... 10 with load imbalance in 2 poles from cold x3 8.4 16.5 24.5 32.5 ...


 

thermistor tripping units 5.5 106 49 32 45 =5 58 z00 ez00 z1 ez1 4.7 a c1 ... c mda mde a1 ez00 ez00 2 m4 x 12 ez1 2 m5 x 15 a3 mda a2 mde b2 b3 ez1 60 50 ... 41.5 30 86 42.5 ­ 75 36 ­ 112 102 12 a a1 a2 a3 b b1 b2 ... b3 b4 b5 c c1 45 35 34 22.5 85 42.5 60 75 41 7.5 73 90 b1 b b4 z5 sk a1 a3 ... a1 a2 a3 b b1 b2 b3 c c1 d e 100 80 80 28 117 74 135 22 133 82.5 94 6 z5 sk4 118 ... 80 100 28 117 74 135 23 133 84 94 7 b1 b2 b z5 a2 a e a ...


 

-phase and dc current motors 1-pole 2-pole tripping characteristics these tripping ... are mean values of the spread at 20°c ambient temperature in a cold state ... overload relay reduces to approximately 25 of the read off value 2h zb12 100 60 ... zb32 40 zb65 ze 20 10 6 4 2 1 40 3-phase 20 10 6 4 2-phase 2 1 0.6 1 1.5 ... 2 3 4 6 8 1015 20 x setting current 2h 100 60 40 20 10 6 4 2 1 40 20 10 6 4 2 ... 1 0.6 z5 3-phase 2-phase 1 1.5 2 3 4 6 8 1015 20 x setting current 2h 100 60 ... 40 20 10 6 4 2 1 40 20 10 6 4 2 1 0.6 zw7 minutes minutes minutes ... level seconds seconds seconds 1 1.5 2 3 4 6 8 10 15 20 x rated current 83 ...


 

actuated from front [°c [°f [°c [°f -25/50 °c -13/122°f -25/40 °c -13/104°f iec ... ul csa damp heat constant to iec 60068-2-78 damp heat cyclic to iec 60068-2-30 -25/ ... 50 °c -13/122°f -25/40 °c -13/104°f -25/50 °c -13/122°f -25/40 °c -13/104°f ... continuous see page 83 0.09 10 ip20 -25/50 °c -13/122°f -25/40 °c -13/104°f -25 ... /50 °c -13/122°f -25/40 °c -13/104°f [kg [g 0.15 10 ip00 0.25 ... back-ofhand proof 6000 iii/3 690 690 440 440 40 ­ 540 ­ main contacts rated ... compensation residual error 20 °c short-circuit protection rating ... flat conductor number of segments x width x thickness busbar width push- ... v ac [v ac [v ac [a 6000 iii/3 690 690 440 440 0.1 ­ 32 0.25 see page 78 2.5 6 2 x ...


 

data overload relays ze 6000 iii/3 2 x 0.75 ­ 2.5 2 x 0.5 ­ 1.5 2 x 18 ­ 12 m3 ... .5 0.8 ­ 1.2 2 0.8 x 5.5 690 500 300 6 zb12 zb32 zb65 6000 ... iii/3 2 x 0.75 ­ 4 2 x 0.75 ­ 2.5 2 x 18 ­ 12 m3.5 0.8 ­ 1.2 2 1x6 500 500 ... 240 6 z5 iff250 6000 iii/3 2 x 0.75 ­ 4 2 x 0.75 ­ 2.5 2 x 18 ­ 12 m3.5 0.8 ­ 1.2 ... 2 1x6 500 500 240 6 zw7 6000 iii/3 2 x 0.75 ­ 4 2 x 0.75 ­ 2.5 2 x 18 ­ 12 m3. ... 5 0.8 ­ 1.2 2 1x6 500 500 240 6 auxiliary and control circuit ... current ac-15 make contact 120 v 240 v 415 v 500 v break contact 120 v 240 v 415 v ...


 

aids l1 l2 l3 n z1 menu class 5 10 15 20 25 30 35 40 95 97 05 07 on off z2 c1 c2 ... class free parameter 1 free parameter 2 reset hand auto if 1 free parameter 1 ... class 5 1.00 class 10 1.00 class 15 1.22 class 20 1.41 class 25 1.58 class 30 1. ... 73 class 35 1.89 class 40 2.00 relays with integrated sensor with the ... zev-xsw-25 to zev-xsw-145 push-through sensors the motor supply ... 1 a the motor supply leads with the zev-xsw-25 are inserted in loops the number of ... ie between lowest and highest value a a 4 0.31 ­ 0.4 1.24 ­ 1.6 3 0.41 ­ 0.62 1. ... 23 ­ 1.86 2 0.63 ­ 1.24 1.26 ­ 2.48 the current setting ie of the device is ... calculated as ie n x in 91 ...


 

can be selected tripping time in s ± 20 setting current ie x3 x4 x5 x6 x 7.2 ... x8 x 10 class 5 11.3 8 6.1 5 4.1 3.6 2.9 10 22.6 15.9 12.3 10 8.2 7.3 5.7 15 34 ... 23.9 18.4 15 12.3 10.9 8.6 20 45.3 31.8 24.6 20 16.4 14.6 11.5 25 56.6 39.8 30.7 25 ... 20.5 18.2 14.4 30 67.9 47.7 36.8 30 24.5 21.9 17.2 35 79.2 55.7 43 35 28.6 25.5 ... 20.1 40 90.5 63.6 49.1 40 32.7 29.2 23 with 3-pole symmetric loading from cold ... class trecovery min 5 5 10 6 15 7 20 8 25 9 30 10 35 11 40 12 with unbalance 50 ... with phase failure the trip occurs in 2.5s thermistor tripping rated trip ...


 

operators tamper proof to iso 13 850/en 418 can be secured by means of sealable ... to iec/en 60 947-5 -1 a page 05/026 4 indicating lights flush and conical ... with and without text can be engraved 2 centering adapter for centering ... voltage range 18 ­ 30 v ac/dc 85 ­ 264 v ac a page 05/027 4 key-operated ... titanium or black · mounting diameter 22.3 mm · minimum grid dimension 30 x 40 mm ...


 

tamper proof to iso 13 850/en 418 pull to release max number of contacts ... that can be used 3 x m22 ck 1 1 14 22 13 21 nema/ul/csa 12 13 3r 4x ce color ... color 1 red m22-pv/kc11/iy-na 109496 ­ 2 12 22 11 21 red m22-pv/kc02/iy-na ... tamper proof to iso 13 850/en 418 pull to release max number of contacts ... that can be used 4 x m22 ck ­ 1f 21 red m22-pv/k01 216515 m22-pv/k11 216516 ... 22 1 1f 13 21 red 14 22 emergency-stop operator ­ ­ ­ red m22- ... pv 216876 stop pushbutton operator emergency-stop ... illuminated ­ ­ ­ black m22s-pv 225528 m22-pvl 216878 ­ ­ ­ red emergency-stop ... individual lock mechanisms ­ ­ ms2 ­ 20 individual lock mechanisms ­ ­ ­ ­ red ...


 

numbers on mounting adapter 1 3 2 m22-a 216374 contact elements with ... terminals front mounting 1 ­ ­ 1f .3 0 .4 .1 2.7 5.5 1 1 3 3 2 2 m22-k10 216376 ... m22-k01 216378 0 1.0 .2 5.5 base mounting 1 ­ .3 0 .4 2.7 5.5 2 ... 3 1 m22-kc10 216380 m22-kc01 216382 ­ 1f .1 0 1.0 .2 5.5 2 3 1 contact ... cage clamp3 front mounting 1 ­ .3 0 .4 2.8 5.5 1 1 3 3 2 2 m22-ck10 216384 m22- ... ck01 216385 ­ 1f .1 0 1.0 .2 5.5 base mounting 1 ­ ­ 1f .3 0 .4 .1 2 ... .8 5.5 2 2 3 3 1 1 m22-ckc10 216386 m22-ckc01 216387 0 1.0 .2 5.5 contact ... and mounting adapter front mounting 21 13 1 1f 14 22 1 0 1.0 2.7 5.5 3 2 m22- ...


 

cable entry knockouts quantity x m20 type article no price see price ... aluminium light anodized ip54 ip54 1 1 2 3 4 5 6 yellow gray ­ ­ ­ ­ ­ ­ ­ m22- ... ey1 216542 m22-e1 216541 m22-e2 216543 m22-e3 216544 m22-e4 216545 m22-e5 ... 216546 m22-e6 216547 shrouds plastic light gray ip55 1 2 3 ... ip40 4 5 6 gray 3 4 4 4 5 6 m22-h1 216548 m22-h2 216549 m22-h3 216550 m22-h4 ... 216551 m22-h5 216552 m22-h6 216553 set of plaster keys consists of two ... of shrouds in plaster ­ ­ ­ ­ m22-upe 216554 notes 1 yellow ral 1004 light gray ral ...


 

entry knockouts nema/ul/csa 12 13 3r 4x ce type article no price see price ... list bottom quantity x m surface mounting enclosure ip66 with ... screws for emergency-stop buttons 1 1 2 2 x 16 2 x 16 2 x 16 sides quantity x ... pg color1 2 x 16 1 x 13.5 2 x 16 1 x 13.5 2 x 16 1 x 13.5 yellow gray gray ... m22-iy1-pg 229234 m22-i1-pg 229233 m22-i2-pg 229235 3 2 x 16 2 x 16 2 x 13 ... .5 gray m22-i3-pg 229236 4 2 x 16 2 x 16 2 x 13.5 gray m22-i4-pg 229237 6 2 x ... 16 2 x 16 2 x 13.5 gray m22-i6-pg 229238 surface mounting enclosures ip55 12 2 x ...


 

circuit devices tmean ac at ta +25 °c blade terminal to din 46 244 1 x 6.3 ... x 0.8/2 x 2.8 x 0.8 mm for contact and lamp socket ... elements use insulated ferrules to din 46 245 bt483 059904 ba 9s filament bulbs ... indicating lights maximum length 28 mm diameter 10 mm made from selected ... high-quality components 110 ­ 130 v/2.4 w 6 v/2.0 w 12 v/2.0 w 24 v/2.0 w 48 v/ ... 2.0 w 60 v/2.0 w 24 v/1.2 w ba 9s neon bulbs for compact ... indicating lights maximum length 28 mm diameter 10 mm 110 ­ 130 v ac/0.1 w ... 220 ­ 240 v ac/0.33 w ba 9s single-chip leds for ... ac and dc positive pole connected to x1 protected against polarity reversal ... -in suppressor circuit up to 1500 v 2000 h 5000 h 5000 h 5000 h 5000 h 5000 h ...


 

colors white green red yellow blue 2 a page 05/047 5 pushbuttons momentary ... two or three positions switching angle 45° spring-return and maintained various ... two or three position switching angle 45° spring-return and maintained ... and minimum grid dimensions 18 x 18 mm or 25 x 25 mm · mounting diameter ... 16.2 mm to en 50 007 · degree of protection ... electronic devices to iec/en 61 131-2 · technical data to iec/en 60 947-5-1 ... tamper proof to iso 13 850/en 418 1 n.c contact element red with blade ... safety function to iec/en 60 947-5 -1 4 indicating lights flush and conical ...


 

nema 13 ip65 momentary button plate 18 x 18 mm type article no 25 x 25 mm type ... q18d-11 086332 q18d-10 086299 q18d-20 054041 q18d-19 054040 q18d-sw 086788 ... q18d-ge 086417 q18d-bl 086384 q18d-x 093623 q18dr-sw 086269 q18dr-ws 086243 ... q18dr-ge 090482 q18dr-bl 090241 q18dr-x 093625 q25d-111 102422 q25d-110 102421 ... q25d-ge 086343 q25d-bl 086328 q25d-x 093624 q25dr-sw 088739 q25dr-ws 088701 ... q25dr-ge 088404 q25dr-bl 088110 q25dr-x 093626 maintained black white green red ... yellow blue without contact elements 1 2 admissible operational voltage 5 ­ 250 ... v 1 1f .3 green 0 2,2 3,7 mm e10 090351 e01 090401 e10 090351 ...


 

n.c key removeable in position color 18 x 18 mm type article no 25 x 25 mm type ... list selector switches nema 13 ip65 2 positions includes vs anti-rotation ... guard ring v v 45° 45° q18wk1 036515 q18wk1r 036598 q25wk1 ... operated selector switches nema 13 ip65 2 positions includes 1 key and vs anti- ... to one lock mechanism vvvvvvvv 45° 45° 45° 45° 45° 45° 45° 45° 45° 45° 45° 0 0 0 0 ... q25s1r-bl 045502 contact elements1 2 admissible operational voltage 5 ­ 250 ... v 1 .3 green 0 2,2 3,7 mm e10 090351 e01 090401 e10 090351 ... e01 090401 .4 1f .1 red 0 1 3,7 mm .2 notes 1 xy x sequence numbers on front ... y function numbers on contact element xy 2 snaps firmly on the sides of the ...


 

key removeable in position color 18 x 18 mm type article no 25 x 25 mm type ... includes vs anti-rotation guard ring 45° x 45° 45° 45° 45° x c c 45° 45° 45° ... includes vs anti-rotation guard ring 45° x 45° 0 45° 45° 45° 45° 45° 45° 45° 45 ... ° other individual lock 45° mechanisms each color 45° corresponds ... to one lock mechanism 45° 45° 45° 45° 45° 45° xxxxccccxxxxxxxx 45° 45° 45° 45° 45 ... ° 45° 45° 45° 45° 45° 45° 45° 45° 45° 45° 45° iiiiiii 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ... aids and accessories contact elements1 2 admissible operational voltage 5 ­ 250 ...


 

60 947-5-1 n.o n.c thumb-grip color 18 x 18 mm type article no 25 x 25 mm type ... selector switches nema 13 ip65 2 positions includes vs anti-rotation ... guard ring without filament bulb v 45° vvvvv 45° 45° 45° 45° 45° white red ... guard ring without filament bulb 45° x 45° 45° 45° 45° 45° 45° 45° 45° 45° 45° 45 ... ° 45° xxxxxcccccc 45° 45° 45° 45° 45° 45° 45° 45° 45° 45° 45° white red green ... q25lwk3r2-gn 072369 contact elements1 2 admissible operational voltage 5 ­ 250 ... v 1 .3 green 0 2,2 3,7 mm e10 090351 e01 090401 e10 090351 ... e01 090401 .4 1f .1 red 0 1 3,7 mm .2 notes 1 xy x sequence numbers on front ...


 

momentary thumb-grip color 18 x 18 mm type article no 25 x 25 mm type ... selector switches nema 13 ip65 2 positions includes vs anti-rotation ... guard ring with filament bulb 24 v v 45° white q18lwk1-ws/wb 038978 q18lwk1-rt/ ... wb v 45° red 038930 v 45° green q18lwk1-gn/wb 038883 v 45° white ... q18lwk1r-ws/wb 039335 v 45° red q18lwk1r-rt/wb 039248 v 45° green ... -rotation guard ring with filament bulb 24 v 45° x 45° white q18lwk3-ws/wb 072334 ... 45° x 45° red q18lwk3-rt/wb 072335 45° x 45° green q18lwk3-gn/wb 072336 45° x 45 ... ° white q18lwk3r-ws/wb 072337 45° x 45° red q18lwk3r-rt/wb 072338 45° x 45° ... green q18lwk3r-gn/wb 072339 45° 45° 45° 45° 45° 45° cccccc 45° 45° 45° 45° 45° 45° ...


 

elements square style front dimensions 25 x 25 mm type article no ul csa iec ... 13 ip65 tamper proof to iso 13 850 en 418 red plunger remains in actuated ... illuminated with integral multiple led 24 v dc ie 15 ma positive pole connected ... to x1 no need to change the bulb q25lpv ... emergenza yellow with black text 50 x 50 mm o 60 mm square round sqt1 058874 ... 063263 sr-ge 063264 contact elements1 2 admissible operational voltage 5 ­ 250 ... v 1 1f .3 green 0 2,2 3,7 mm e10 090351 e01 090401 .4 .1 red ... 0 1 3,7 mm .2 notes 1 xy x sequence numbers on front element y ... function numbers on contact element xy 2 snaps firmly on the sides of the ... fast-on connectors ul listed file no e 29 184 csa certified file no 46 552 3 ...


 

price see price list tmean ac at ta +25 °c filament bulbs wedge base w 2 x 4.6 ... d 6 v/1.0 w 12 v/1.0 w 24 ­ 28 v/1.0 w multiple leds wedge base w 2 x ... 4.6 d for ac/dc 6 v/45 ma 10000 h 15000 h 7000 h wbgl6 090223 ... -gn12 055715 wbled-rt12 055716 12 v/24 ma 60000 h yellow green red single-chip ... led wedge base w 2 x 4.6 d positive pole to x1 integral ... h yellow green red white blue ledwb-y 208724 ledwb-g 208725 ledwb-r 208726 ledwb-w ... 208728 ledwb-b 208727 r16-ms 090297 assembly tool for lock ... bulb extractor terminal insulator for 2.8 x 0.8 mm fast-on connectors can be push ... from the front also suitable for .110 x .32 inch fast-on receptacles amp 60197 ...


 

rate approx 60/min a page 05/068 2 basic module easy to assemble with ... in tubular column terminal connection 6 x 1.5 mm2 approx awg 24 14 includes top ... in four lengths base 90° wall mounting 4 hole mounting a page 05/069 7 lenses ... grooves ensure even light distribution 4 control circuit devices continuous ... volume approx 90 db at 60 cm frequency 2750 hz 5 ...


 

shock resistance to iec 60 068-2-27 half-sinusoidal shock duration 11 ms ... terminal capacity cu only 1 or 2 wire dimensions contacts iec data rated ... degree control circuit reliability at 24 v dc/5 ma fault probability hf 5 v dc/1 ... ma fault probability hf °c g -25 70 as required 30 -25 701 as required ... 30 -25 70 as required 30 -25 70 as required 30 -25 70 as required ... 30 operations x 106 ops/h n nm ul csa iec/en 60 947 vde ... ­ ip20 ­ ­ ­ ­ ip20 5 3600 f5 ­ ip66 0.2 3600 f5 ­ ip65 0.1 2000 ­ f 0,3 ip66 ... shock resistance to iec 60 068-2-27 half-sinusoidal shock duration 11 ms ... dimensions °c g -25 70 as required 30 a page 05/075 -25 70 ... as required 30 a page 05/075 -25 70 as required 30 a page 05/075 -25 70 ... ip66 damp heat constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 ...


 

control circuit devices operations x 105 ops/h n nm ul csa iec/en 60 947 vde ... 0660 100 30 3 3600 3600 1800 3 4 ­ ­ ip20 with ish2,8 ip65 damp heat ... constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 60 -25 40 as required 40 -25 60 -25 40 as required 40 3 1800 ­ 0.2 ip65 ... 60 947 vde 0660 30 3 3 3600 1800 1800 4 ­ ­ f 0,2 ip65 ip65 damp heat constant ... to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 60 -25 40 as required 40 ­ ­ ­ a page 05/080 -25 60 -25 40 as ... required 40 ­ ­ ­ a page 05/08 3 1800 ­ f 0,4 ip65 ... 0.5 600 25 ­ ip65 0.5 600 25 ­ ip65 ambient temperature open ... shock resistance to iec 60 068-2-27 half-sinusoidal shock duration 11 ms ...


 

pushbuttons control circuit devices 21.5 21.4 19.3 30 30 45 pushbutton with m22 ... ck 17.8 surface mounting adapter a 22.4 10 10 30 10 45 71 3.1 56.7 35.2 1 x m22 ... -k 2 x m22-k 1 x m22-ck 2 x m22-ck a 37.2 37.2 39 39 pushbutton ... indicating light with telescopic clip 20 20 m22 tcv m22-d m22-l m22-w m22-p ... 4.5 45 60 ­ 100 10 39 10 foot and palm ... switches fak 4.5 m4 m22-d m22-l m22-w m22-p 22.4 54. ...


 

a1 e y 1 72 e2 105 e3 138 e4 171 e5 204 e6 237 shrouds m22-h a2 e 56 89 122 ... 155 188 221 95 type m22-i y 1 m22-i2 m22-i3 m22-i4 ... -part m20 m20 m20 number of locations 1 2 3 4 6 a 72 120 153 186 252 e 58.5 106.5 ... 139.5 172.5 238.5 cable entries 2 x m16 2 x m16 2 x m16 2 x m16 2 x m16 1 x ... pg13.5 1 x pg13.5 2 x pg13.5 2 x pg13.5 2 x pg13.5 2 x pg16 2 x pg16 2 x ... pg16 2 x pg16 2 x pg16 type h1 h2 h3 h4 h5 h6 a2 42 75 ... 108 141 174 207 cable entry 3 x m20 4 x m20 4 x m20 4 x m20 5 x m20 6 x m20 59 ...


 

cover number of contacts 1 n.o 1 n.c 2 n.o 2 n.c as snap-action or standard ... along the device s position axis 2 roller lever for high speed single- ... /009 11 basic device wide version with 2 x m20 number of contacts 1 n.o 1 n.c 2 ... n.o 2 n.c as snap-action or standard action ... contacts page 06/004 7 at 4 enclosures/switch mechanisms operating ... with a steel-spring rod 3 page 06/016 4 operating heads can be rotated 90° ... elements page 06/016 9 enclosure at 4 narrow version to en 50 041 page 06/016 ... of contacts 1 n.o 1 n.c page 06/016 2 7 12 8 enclosure at 4 wide version with ... 3 x m20 page 06/016 product features at 0 ... atr at 4 · modular system · degree of protection ... nema 4 13 and iec ip 65 · · personnel ...


 

instrumentation selector switches 3 x phase-phase with off position t0-2- ... -na 110096 ivs-na 110103 z-na 104487 1 2 l1-l2 l2-l3 l3-l1 3 4 5 6 7 8 l2-l3 l1- ... l2 l3-l1 fs 164854 3 x phase-phase without off position 3 x ... phase to neutral with off position t0-2-15922 e 053099 ez 055472 i2-na 110097 ivs ... 060218 z 062591 t0-2-15177 e-na 104488 ez-na 104489 i2-na 110098 ... ivs-na 110104 z-na 104490 1 2 l3-l1 l2-l3 l1-l2 0 l1-n l2-n l3-n 3 4 ... 5 6 7 8 9 10 11 12 3 x phase-phase 3 x phase to neutral with off position t0-3 ... -na 110099 ivs-na 110105 z-na 104610 1 2 l1-l2 l2-l3 l3-l1 l1-n l2-n l3-n 3 4 5 ... 6 7 8 9 10 11 12 3 x phase-phase 3 x phase to neutral without off position ...


 

t3 e i2 z p1 e i2 z t0-1 up to t0-4 i2 e t3-1 up to t3-5 i2 t3-1 up to ... z p1 e i2 z padlockable with up to 2 padlocks interlocked positions pre- ... t3 only position a is locked example 2 svca,e t3 positions a and e are locked ... a through j are locked range example 4 dtvg t3 push-release mechanism needs to ... emergency-stop function per iec/en 602-4-1 with red handle and yellow front plate ... plate yellow c b d 330 300 315 e 0 30 45 f g h 60 90 a specified positions need ... in its released state with up to 2 padlocks locking cams 2 cams per set ... all switching angles +dtv t3 104291 ­ 270 240 225 135 210 180 150 j k 120 rqpnml ... all switching angles for dtv-t3 order 2 x vr-t3 ­ vr-t3 050987 spare keys ...


 

see price list cable entries quantity 2 x o 20 mm 2 x o 15 mm cross-section 5 ... x 6 mm2 5 x 2,5 mm2 cam switches motor disconnect ... for cover mounted switches with up to 4 contact chambers t0 e t3 e p1 e h3-t0 ... for protection of terminals for up to 2 contact chambers extension of h1-t5 ... and/or outgoing conductors order 2 covers in the case of both 1 hz-t5 ... and/or outgoing conductors order 2 covers in the case of both to cover ... and/or outgoing conductors order 2 covers in the case of both the cover ... of a 5 pole switch 3 power poles and 2 auxiliary modules unused portions of ...


 

shock resistance shock duration 20 ms main contact rating per iec/en 60 ... in intermittent operatin class 12 ab 60/40/25 short circuit rating max fuse rated ... flexible with ferrule 1 ferrule to din 46 228 terminal screw metric max ... ul csa iec/en 60 947 vde 0660 iec/en 60 204 switch-disconnectors to iec/en 60 947-3 ... -break switch to iec/en 60 947-3 106 5 x 105 3000 3000 damp heat constant to iec ... 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 50 -25 50 -25 40 -25 40 as required a page 07/076 a page 14/020 ... 15 690 6000 iii/3 22/20 1,3/1,6/2 x ie 20 320 440 15 2 690 6000 iii/3 35/ ... 32 5 x 105 3000 -25 50 -25 40 a page 07/081 15 690 6000 iii/3 72/63 ...


 

disconnect switches technical data p1-25 p1-32 p3-63 p3-100 cam switches motor ... shock resistance half-sinusoidal shock 20 ms main contact ratings per iec/en 60 ... intermittent operation class 12 ab 60/40/25 df short-circuit rating max fuse ... flexible with ferrule 1 ferrule to din 46 228 terminal screw metric max ... tightening torque notes g v ac v a x ie a gl/gg aeff up to v ac v ac ul,csa ... iec/en 60 947 vde 0660 iec/en 60 204 switch-disconnector to iec/en 60 947-3 ... 3 x 105 3 x 105 105 50 50 50 damp heat constant to ... iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 50 -25 50 -25 50 -25 40 -25 40 -25 40 as required a page 07/083 a page 14/020 ... 20 20 20 690 6000 iii/3 25 1,3/1,6/2 25 640 660/690 440 690 6000 iii/3 32 1, ...


 

combinaisons selon les modèles qqqq 30 45 60 90 qqqt0 t3 t5b max characters ... sur plaque fs degrees degrés 0,180 30 210 330 45 135 225 315 60 120 240 300 90 ... 270 150 t03 13 8 6 5 4 8 t5b 13 8 7 7 7 8 qqqqqqqqqqq 1 2 3 4 ... 11 qqqqqqqqqqq 12 13 14 15 16 17 18 19 20 21 22 qqqqqqqqqqqe ea/svb q ea/svb-sw ... i svb q i svb-sw ivs v/svb q v/svb-sw x q xz z s-t0 front plate no plastron ... n° contact chambers/galettes 1 2 3 4 5 6 7 8 9 10 11 fs k complete ... totale k spring return retour autom 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ... 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 ...


 

the main prix unitaire catalog qqqq 30 45 60 90 qqqt0 t3 t5b reportez-vous au ... les modèles degrees degrés 0,180 30 210 330 45 135 225 315 60 120 240 300 90 ... 270 150 t03 13 8 6 5 4 8 t5b 13 8 7 7 7 8 qqqqqqqqqqq 1 2 3 4 ... 11 qqqqqqqqqqq 12 13 14 15 16 17 18 19 20 21 22 qqqqqqqqqqqe ea/svb q ea/svb-sw ... i svb q i svb-sw ivs v/svb q v/svb-sw x q xz z front plate no plastron n° ... contact chambers/galettes 1 2 3 4 5 6 7 8 9 10 11 fs k complete ... totale k spring return retour autom 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ... 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 330 300 315 ... 270 240 225 210 30 45 60 90 135 120 150 180 marking/repérage ...


 

module normal switching duty ac-3/400v kw a 5,5 11.4 3 2.2 1.5 1.1 0.75 0.55 ... rated operational current e 50 60 hz 4 1.8 8 1.8 6 1.2 5 1.6 3 1.65 2 1.86 1. ... 42 0.1 0.2 0.4 0.6 0.8 1 2 3 4 5 6 8 10 normal switching duty s00 se00 ... processing machines starting up to 6 x motor rated current stopping 1 x motor ... 100 ac-3 extreme switching duty ac-4/400v a kw 11.4 5.5 8.8 4 3 6.8 rated ... operational current e 50 60 hz 2.2 1.5 1.1 0.75 0.55 0.37 0.25 5.2 3.6 2. ... 65 1.86 1.42 1.05 0.81 0.01 0.02 0.03 0.04 0.06 0.1 ... 0.2 0.3 0.4 0.6 1 2 3 4 component lifespan millions of ... and processing machines starting 6 x motor rated current stopping 6 x motor ... rated current 100 ac-4 rated output of three-phase motors 50 ...


 

pkzm0 se00 pkzm0 s00 minutes 10 5 2 1 40 20 10 5 2 1 200 pkzm0 t ... milliseconds 50 20 5 2 1.5 2 6 3 4 8 10 x rated operational current 15 20 30 let- ... energy values manual motor protectors 2 pkzm0 pkm0 [ka hal 4 3 2 1 0.8 0.6 0. ... 4 0.3 0.2 2 cc ·i 6.3 a 4.0 a [a s 6 4 3 2 1.5 4 10 8 6 4 3 2 f-w ave 6 25 a ... 20 a 16 a 10 a dt 10 8 5 pkzm 0 25 a 20 a 16 a 2 1 st 10 a 6.3 a 2.5 a 1.6 a 4. ... 08 0.06 0.04 0.03 0.02 0.015 0.01 1 1.5 2 3 4 6 8 10 15 20 u e 400 v 0.63 a 1.5 ... 3 10 8 6 4 3 2.5 a 1.6 a 0.4 a 2 1.5 10 e 400 v 2 1 1.5 2 3 4 0.25 a 30 ... 40 60 80 100 i cc eff 1.0 a 6 8 10 15 20 30 40 60 80 100 ccrms [ka [ka let- ...


 

08/058 pkz 2 motor protectors selection guidelines ... module normal switching duty ac-3/400v kw 18.5 15 11 7.5 5.5 4 3 2.2 1.5 1.1 0 ... .75 0.55 0.37 0.25 a 35 28.5 22.1 15.4 11.4 8.8 6.8 5.2 3.6 2.65 1.86 1.42 1. ... 05 0.81 0.1 0.2 se1a pkz2 squirrel-cage motors ... stopping normal switching duty 0.4 0.6 0.8 1 2 3 4 5 6 8 10 component ... machines electrical starting up to 6 x motor rated current characteristics ... stopping 1 x motor rated current utilization ... 50 60 hz extreme switching duty ac-4/400v kw 18.5 15 11 7.5 5.5 4 3 2.2 1.5 1.1 0 ... .75 0.55 0.37 0.25 a 35 28.5 22.1 15.4 11.4 8.8 6.8 5.2 3.6 2.65 1.86 1.42 1. ... 05 0.81 0.01 0.02 0.03 0.04 0.06 0.1 0.2 0.3 0.4 0.6 1 2 3 45 component lifespan ...


 

min max min max °c °c °c ul 508 csa c 22.2 no 14 iec/en 60 947 vde 0660 gl lr dnv ... ezu damp heat constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 70 -25 55 -25 40 pkzm 0 pkzm 0/se 00 mounting position ... -sinusoidal shock10 ms to iec 60 068-2-27 altitude terminal capacity iec solid ... protector combination from above ip 20 ip 00 finger and back-of-hand proof ... motor protector 25 motor protector combination 8 2000 1 x ... 1 ­ 6 2 x 1 ­ 2,5 1 x 1 ­ 4 2 x 1 ­ 2,5 14 ­ 10 1,8 1,0 6000 iii/3 690 25 or ... thermal trip dial setting 40 ­ 60 motor protector 6 main contacts ... manual motor protector type 100 ac-3/400 v motor protector combination 9,5 ops ... high capacity magnetic contactor 0,1 x 106 5,0 x 106 refer to utilization ...


 

iec kw ratings ac-3 ac-3 kw rating at 220 v 230 v 240 v kw 0.06 0.09 0.12 0.25 0. ... 37 0.75 1.1 2.2 4 5.5 5.5 0.06 0.09 0.12 0.25 0.37 0.75 1 ... .1 2.2 380 v 400 v 415 v kw 0.06 0.09 0.12 0.25 0.55 0.75 1.5 ... 2.2 4 7.5 9 12.5 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 4 440 v kw 0.06 0.12 ... 0.18 0.25 0.55 1.1 1.5 3 4 9 11 12.5 0.06 0.12 0.18 0.25 0.55 1.1 ... 1.5 3 4 500 v kw 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 9 12.5 15 0.06 0. ... 12 0.25 0.37 0.75 1.1 2.2 3 4 660 v 690 v kw 0.06 0.12 0.18 0.25 0.55 ... 1.1 1.5 3 4 7.5 12.5 15 22 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 ...


 

current ie ac-15 a600 q300 nhi s agm 220 ­ 240 v 380 ­ 415 v 440 ­ 500 v 24 v 60 ... v 110 v 220 v mechanical aaaaaaa ops 3,5 2 1 2 1,5 ... 1 0,25 nhi nhi-e agm nhi s hi nhi nhi-e agm ... 1 for nhi-e pkz0 0,5 for nhi-e pkz0 0,1 x 106 0,01 x 106 5 x 106 0,05 x 106 0,1 x ... 106 5 x 103 1 x 106 108 operations lifespan electrical ... ops control circuit reliability at ue 24 v dc umin 17 v lmin 5,4 ma positively ... driven contacts to zh 1/457 short-circuit rating without welding ... fuse terminal capacity 1 conductor or 2 conductors iec/en solid or flexible ... u e terminal capacity 1 conductor or 2 conductors iec/en solid or flexible ... /ez a a gl/gg mm2 awg v ac v dc mm2 awg x us x us va va w w x us x us va va ...


 

08/060 pkz 2 manual motor protectors technical data ... min max min max °c °c °c ul 508 csa c 22.2 no 14 iec/en 60 947 vde 0660 gl lr dnv ... meei damp heat constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 - ... 25 70 -25 60 -25 40 90 ° pkz 2 pkz 2 s pkz 2 cl pkz 2 s mounting position 90 ... ° 30° pkz 2 90° 90° s cl pkz 2 pkz 2 cl ° 90 s cl direction of incoming ... shock resistance half-sinsoidal shock 20 ms to iec 60 068-227 altitude terminal ... g m mm2 mm2 awg nm nm as required ip 20 motor protector 30 2000 motor protector ... combination 8 1 x 1 ­ 16 or 2 x 1 ­ 6 1 x 1,5 ­ 10 or 2 x 1,5 ­ 6 14 ­ ... ,8 1,0 v v ac a hz w ops 6000 iii/3 690 40 50 ­ 60 motor protector 14 motor ...


 

08/064 pkz 2 manual motor protectors technical data ... maximum rated current type b 3.1/2-pkz2 type b3.1/3-pkz2 bus connector incoming ... 600 85 100 v ac a awg nm 600 100 14 0 4.5 pkz2/zmr s motor protector trip curve ... ranges at an ambiant temperature of 20°c starting from cold the tripping time of ... request these characterstics inn 55 x 75 mm format are self-adhesive and can ... laboratory ptb certificate no 3.53/388.299 tripping characteristcs on request ... setting range a 0,4 ­ 0,6 0,6 ­ 1,0 1,0 ­ 1,6 1,6 ­ 2,4 2,4 ... ­ 4,0 4,0 ­ 6,0 6,0 ­ 10 10 ­ 16 16 ­ 25 25 ­ 32 32 ­ 40 tripping characteristic ... to awa no 128-881-1 128-881-2 128-881-3 128-881-4 128-881-5 128-881-6 ... -881-8 128-881-9 128-881-10 128-881-11 2h 20 minutes 10 5 2 1 40 secondes 20 10 5 ...


 

sequence when installed in position 1.1 2 contact sequence when installed in ... position 1.2 1 1.13 2 +ek10 051082 ek10 027039 two ek type ... as those indicated by voltage trips 4.13 +ek10 051082 ek10 027039 one ek type ... molded case switch for trip indication 4.14 4.11 +ek01 051083 ek01 031785 4.12 ... as follows nhi rhi vhi a avhi u 2 x ek 1 x ek ...


 

ul489 and csa certified csa c22.2 no 5-02 as branch circuit breakers ... time of instantaneous trip 5 ­ 10 x in current rating current limiting ... expected instantaneous trip is 5 to 10 x rating of device in applications ... c ­ designed for inductive loads 1 pole 2 poles 3 poles rated current in a 0.5 1 ... 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 type faz-co,5/1-na faz-c1/1 ... /1-na faz-c40/1-na price type faz-c0,5/2-na faz-c1/2-na faz-c1,5/2-na faz-c2/2-na ... faz-c3/2-na faz-c4/2-na faz-c5/2-na faz-c6/2-na faz-c7/2-na price type faz- ... 3-na faz-c7/3-na price see green faz-c8/2-na pages faz-c10/2-na faz-c13/2-na faz-c15 ... /2-na faz-c16/2-na faz-c20/2-na faz-c25/2-na faz-c30/2-na faz-c32/2-na faz-c35/2-na ...


 

ul489 and csa certified csa c22.2 no 5-02 as branch circuit breakers ... time of instantaneous trip 10 ­ 20 x in current rating current limiting ... expected instantaneous trip is 10 to 20 x rating of device in the high ... for highly inductive loads 1 pole 2 poles 3 poles rated current in a 0.5 1 ... 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 type faz-d0,5/1-na faz-d1/1 ... /1-na faz-d40/1-na price type faz-d0,5/2-na faz-d1/2-na faz-d1,5/2-na faz-d2/2-na ... faz-d3/2-na faz-d4/2-na faz-d5/2-na faz-d6/2-na faz-d7/2-na price type faz- ... 3-na faz-d7/3-na price see green faz-d8/2-na pages faz-d10/2-na faz-d13/2-na faz-d15 ... /2-na faz-d16/2-na faz-d20/2-na faz-d25/2-na faz-d30/2-na faz-d32/2-na faz-d35/2-na ...


 

ul489 and csa certified csa c22.2 no 5-02 as branch circuit breakers ... time of instantaneous trip 5 ­ 10 x in current rating interrupting capacity ... expected instantaneous trip is 5 to 10 x rating of device in applications ... c ­ designed for inductive loads 1 pole 2 poles 3 poles rated current in a 0.5 1 ... 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 type faz-co,5/1-rt faz-c1/1 ... /1-rt faz-c40/1-rt price type faz-c0,5/2-rt faz-c1/2-rt faz-c1,5/2-rt faz-c2/2-rt ... faz-c3/2-rt faz-c4/2-rt faz-c5/2-rt faz-c6/2-rt faz-c7/2-rt price type faz- ... ring-tongue connectors see green faz-c8/2-rt pages faz-c10/2-rt faz-c13/2-rt faz-c15 ... /2-rt faz-c16/2-rt faz-c20/2-rt faz-c25/2-rt faz-c30/2-rt faz-c32/2-rt faz-c35/2-rt ...


 

ul489 and csa certified csa c22.2 no 5-02 as branch circuit breakers ... time of instantaneous trip 10 ­ 20 x in current rating interrupting capacity ... expected instantaneous trip is 10 to 20 x rating of device in the high ... for highly inductive loads 1 pole 2 poles 3 poles rated current in a 0.5 1 ... 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 type faz-d0,5/1-rt faz-d1/1 ... /1-rt faz-d40/1-rt price type faz-d0,5/2-rt faz-d1/2-rt faz-d1,5/2-rt faz-d2/2-rt ... faz-d3/2-rt faz-d4/2-rt faz-d5/2-rt faz-d6/2-rt faz-d7/2-rt price type faz- ... ring-tongue connectors see green faz-d8/2-rt pages faz-d10/2-rt faz-d13/2-rt faz-d15 ... /2-rt faz-d16/2-rt faz-d20/2-rt faz-d25/2-rt faz-d30/2-rt faz-d32/2-rt faz-d35/2-rt ...


 

time of instantaneous trip 3 ­ 5 x in current rating ul recognized and csa ... is desired instantaneous trip is 3 to 5 x continuous rating of device in ... rated current in a 6 8 10 12 13 15 16 20 25 32 40 50 63 type faz-b6/1n faz-b8/1n ... see green pages 7200 3600 t [s 1.13 1.45 1200 600 300 120 60 30 10 5 2 1 0.5 0.2 ... speci ed non-tripping current int 1.13 x in for t 1 h speci ed tripping current ... it 1.45 x in for t 1 h 2.55 x in t 1 ­ 60 s in 32 a t 1 ­ 120 s ... in 32 a type b 3 x in t 0.1 s type b 5 x in t 0.1 s ... type c 5 x in t 0.1 s type c 10 x in t 0.1 s type d 10 x in t 0.1 s ... type d 20 x in t 0.1 sbcd in north america these ... nec national electrical code article 240 and cec canadian electrical code part ...


 

time of instantaneous trip 5 ­10 x in current rating ul recognized and csa ... expected instantaneous trip is 5 to 10 x rating of device in applications ... c ­ designed for inductive loads 1 pole 2 poles 3 poles 4 poles rated current in ... a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 faz-c1/1 type faz-c0,5/1 faz-c1,6 ... -c40/1 faz-c50/1 faz-c63/1 price faz-c1/2 type faz-c0,5/2 faz-c1,6/2 faz-c2/2 faz ... -c3/2 faz-c4/2 faz-c6/2 price faz-c1/3 type faz-c0,5/3 faz-c1,6 ... faz-c3/3 faz-c4/3 faz-c6/3 price faz-c1/4 type faz-c0,5/4 faz-c1,6/4 faz-c2/4 faz ... -c3/4 faz-c4/4 faz-c6/4 price faz-c8/2 see green faz-c10/2 pages faz-c13/2 faz ... -c16/2 faz-c20/2 faz-c25/2 faz-c32/2 faz-c40/2 faz-c50/2 faz-c63/2 faz-c8/3 ...


 

time of instantaneous trip 5 ­10 x in current rating ul recognized and csa ... expected instantaneous trip is 5 to 10 x rating of device in applications ... neutral rated current in a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 type ... s 7200 3600 1200 600 300 120 60 30 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0. ... 002 0.001 0.0005 1 1.13 1.45 faz-c8/3n see green faz-c10/3n pages ... speci ed non-tripping current int 1.13 x in for t 1 h speci ed tripping current ... it 1.45 x in for t 1 h 2.55 x in t 1 ­ 60 s in 32 a t 1 ­ 120 s ... in 32 a type b 3 x in t 0.1 s type b 5 x in t 0.1 s ... type c 5 x in t 0.1 s type c 10 x in t 0.1 s type d 10 x in t 0.1 s ...


 

response time of instantaneous trip 10 ­20 x in current rating ul recognized and ... expected inst