Page 110 of 649 ![]() |
![]() View extracted text
Page 110 of Current Catalog by Moeller Electric USA03/033 system pkz 2-sp self-protected combination starters fvnr fvr open type max hp rating 3 phase 200 v hp 230 v hp 480 v hp 575 v hp ready to be mounted and wired in its own enclosure trip modules shown below can be selected later according to desired motor hp and flc and plugged into the disconnect to complete the starter type specify coil voltage and frequency a page 03/034 list price see price list notes full voltage non-reversing starter without trip module 10 15 30 25 pkz2/s-sp full voltage reversing starter without trip module 10 15 30 25 pkz2/s-sp-fvr supplied with factory mounted and wired disconnect and mechanically interlocked contactors trip modules shown below can be selected later according to desired motor hp and flc and plugged into the disconnect to complete the starter trip modules max hp rating 3 phase 200v hp 230v hp 460v hp 575v hp a 1 a adjustable thermal current range adjustable magnetic current range type article no list price see price list with overload function type article no list price see price list trip modules are added to above devices to complete starter in this range select devices in accordance with motor flc 1 1 3 1 1 2 0.4 0.6 1 2 5-8 8 14 14 -22 20 35 35 55 50 80 80 140 130 220 200 350 275 425 350 500 zm-0.6-pkz2 024232 zm-1-pkz2 028979 zm-1.6-pkz2 031352 zm-2.4-pkz2 033725 zm-4-pkz2 036098 zm-6-pkz2 038471 zm-10-pkz2 040844 zm-16-pkz2 043217 zm-25-pkz2 045590 zm-32-pkz2 047963 zm-40-pkz2 050336 zmr-0.6-pkz2 033943 zmr-1-pkz2 033950 zmr-1.6-pkz2 033952 zmr-2.4-pkz2 033955 zmr-4-pkz2 033957 zmr-6-pkz2 033966 zmr-10-pkz2 033967 zmr-16-pkz2 033968 zmr-25-pkz2 033969 zmr-32-pkz2 033973 zmr-40-pkz2 033975 /2 0.6 1 1.0 1.6 1.6 2.4 2.4 4.0 4.0 6.0 6 10 10 16 16 27 24 32 32 42 3 4 1 1 1 2 3 5 7 1 2 10 25 1 2 1 2 3 5 10 20 20 30 1 1 1 2 2 3 5 10 10 notes 1 1 1/2 3 5 7 1/2 10 15 set bimetal trips yellow dial to motor flc ·tripping current 125 of setting ·for motors of service factor 1.0 set dial to 0.9 of motor flc setting ·ambient compensated ·phase failure sensitive ul listed csa certified maximum interrupting ratings 240 v ac 100 ka rms sym 480 y 277 v ac 65 ka rms sym 600 y 347 v ac 42 ka rms sym up to 27 a suitable for maximum 600 v ac power distribution system when the voltage between any phase to ground does not exceed 347 v up to 42 a suitable for maximum 480 v ac power distribution system when the voltage between any phase to ground does not exceed 277 v magnetic contactors magnetic starters[close] |
Page 110 of 649 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |