Page 185 of 649 ![]() |
![]() View extracted text
Page 185 of Current Catalog by Moeller Electric USA04/020 z thermal overload relays technical data ze z00 z1 z1-75 z5 k3 z5 k4 04/021 z thermal overload relays technical data z5 ff250 zw7 zev zev-xsw-25 zev-xsw-65 zev-xsw-145 zev-xsw-820 thermal overload relays thermistor tripping units ambient temperature storage temperature temperature compensation dimensions mounting position weight open enclosed min max °c °c page page kg kg g/ms mechanical shock resistance half-sinusoidal shock degree of protection protection against direct contact from the front when actuated by a perpendicular test finger iec 536 main contacts rated impulse withstand voltage uimp overvoltage category/pollution degree rated insulation voltage ui rated operational voltage ue ul/csa safe isolation to iec 536 between the main contacts and the auxiliary contacts as well as between the main contacts current setting short-circuit protection max fuse current heat loss 3 current paths lower value of the setting range maximum setting terminal capacity solid flexible without ferrule flexible with ferrule stranded flexible with cable lug stranded with cable lug solid or stranded flat conductor3 busbar terminal screws pozidriv screwdriver standard screwdriver hexagon socket head wrench hexagon head wrench tightening torque notes 1 ul,csa iec/en 60 947 vde 0660 damp heat constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 -25/501 -25/501 -25/501 -25/401 -25/401 -25/401 continuous 04/024 04/024 04/024 04/019 04/019 04/019 0.07 0.13 0.21 0.34 10/10 10/10 10/10 ip20 ip00 ip00 finger and back-of-hand proof -25/501 -25/401 04/024 04/019 1.3 sk3 1.44 kk3 10/10 ip00 -25/501 -25/401 04/024 04/019 1.41 sk4 1.64 kk4 10/10 ip00 ul csa iec/en 60 947 vde 0660 damp heat constant to iec 60 068-2-3 damp heat cyclical to iec 60 068-2-30 -25/501 -25/501 -25 602 -25/401 -25/401 -25/402 40/80 continuous 04/027 04/027 04/026 04/019 as required as required 1.55 0.8 0.25 10/10 10/10 15/10 ip00 ip00 ip20 with terminal finger and back-of-hand proof cover 8000 iii/3 1000 1000/600 440 50 250 04/006 6000 iii/3 690 690/600 440 40 540 5003 1 8204 -25 601 -25/401 40/80 04/026 as required 0.2 -25 601 -25/401 40/80 04/026 as required 0.4 -25 601 -25/401 40/80 04/026 as required 0.5 -25 601 -25/401 40/80 04/026 as required 0.3 v v ac v ac v ac a page 6000 iii/3 690 690/600 300 0.1 12 04/004 6000 iii/3 690 690/600 440 0.1 24 04/004 6000 iii/3 690 690/600 440 6 75 04/006 8000 iii/3 1000 1000/600 440 25 100 04/006 8000 iii/3 1000 1000/600 440 35 142 04/006 1 25 265 10 145 8000 iii/3 1000 1000/600 40 820 for overload relay in conjunction with transformers as required for contactor 3 10 27 mm w w mm2 mm2 mm2 mm2 mm2 mm2 awg mm mm size mm mm mm nm 2 2.5 6 2 2 0.75 2.5 0.5 1.5 2.5 6 2 2 1 6 1 6 3 7 7.5 10 2 1 162 1 25 2 1 102 14 2 m6 2 1 6 3.5 16 28 16 50 50 50 2 6 9 m8 4 6 16 28 16 70 70 70 2/0 6 16 m10 5 10 16 28 95 120 250 mcm 6 16 0.8 20 3 m8 25 13 10 14 1 2 sw sw 18 14 m3.5 2 0.8 5.5 1.2 814 m4 2 1 6 1.8 0.8 0.8 operating range to iec/en 60 947 ptb 5 °c to +50 °c when using two conductors use equal cross-sections 3 z5 ff250 secure using box terminal operating range to iec/en 60 947 ptb -5 °c to +50 °c limited legibility of the lcd display at -15 °c 3 with zev between busbar and sensor 4 setting range dependent on current sensor thermal overload relays thermistor tripping units general technical data standards climatic proofing[close] |
Page 185 of 649 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |