Page 409 of 649 ![]() |
![]() View extracted text
Page 409 of Current Catalog by Moeller Electric USA08/008 08/009 system pkz 0 magnetic motor protector combinations type pkzm 0 se00 ul/csa short-circuit current rating rms sym 600 v ac ka magnetic motor protector combination 1 ul/csa group installations iec/en 60 947-4-1 type 1 coordination level 50 600 l ul csa iec ce system pkz 0 magnetic motor protector combinations type pkzm 0 se00 type article no list price see price list notes 6 ul csa iec ce manual motor protectors motor protector combinations 4 5 3 aaaa 200 v hp 230 v hp 460 v hp 575 v hp coil voltages shown in for other coil voltages a page 08/043 600 0,1 0,16 0,16 0,25 2,2 3,5 5,6 8,8 14 22 35 56 88 140 ½ 1 1½ 2 ½ 1 1½ 3 ½ ¾ 1 2 3 7½ ½ 1 1½ 3 5 10 in this range select motor protector in accordance with the motor nameplate full load current a1 13 21 0,25 0,4 0,4 0,63 a2 14 22 pkzm0-0,16/se00-11120v60hz 050283 pkzm0-0,25/se00-11120v60hz 050651 pkzm0-0,4/se00-11120v60hz 052338 pkzm0-0,63/se00-11120v60hz 053007 pkzm0-1/se00-11120v60hz 053346 pkzm0-1,6/se00-11120v60hz 053436 pkzm0-2,5/se00-11120v60hz 053445 pkzm0-4/se00-11120v60hz 053454 pkzm0-6,3/se00-11120v60hz 053463 pkzm0-10/se00-11120v60hz 058790 the pkzm 0 se00 and pkzm 0 s00 are motor protector combinations made up of pkzm 0 manual motor protectors and se00 magnetic contactors these motor protector combinations are ul listed and csa certified as assemblies which provide motor controller functions and running overload protection group motor applications pkzm0 se00 motor protector combinations are ul listed and csa certified for group applications as per the intent of nec 430-53 and cec part 1 rule 28-206 this eliminates the need for individual motor branch circuit overcurrent protective devices for each motor thus greatly reducing the cost and space requirements of industrial control panels and assemblies in group installations involving a number of pkzm0 motor protectors the maximum rating of the group branch circuit overcurrent protective device is based on the lowest backup overcurrent rating marked on each motor in the group combined with applicable nec/cec installation rules pkzm0 se00 motor protector combinations are in conformity with type 1 co-ordination levels at up to 500 v ac per iec/en 60 947-4-1 pkzm0 s00 motor protector combinations are in conformity with type 2 co-ordination levels at up to 500 v ac per iec/en 60 9474-1 further during ul/csa short-circuit testing of this combination no heater burn-out or contact welding occurred 3 t 0,63 1 1 1,6 1,6 2,5 2,5 4 4 6,3 22 150 125 6,3 10 accessories 3 standard auxiliary contact 4 standard auxiliary contact for high capacity motor protector combination 5 trip-indicating auxiliary contact 6 shunt trip undervoltage trip additional accessories suppressors for ac features page 08/010 08/010 08/012 08/012 08/017 08/014 magnetic motor protector combination with high capacity contactor ul/csa group installations iec/en 60 947-4-1 type 2 coordination level 50 600 l 600 0,1 0,16 0,16 0,25 2,2 3,5 5,6 8,8 14 22 35 56 88 140 ½ 1 1½ 2 ½ 1 1½ 3 ½ ¾ 1 2 3 7½ ½ 1 1½ 3 5 10 in this range select motor protector in accordance with the motor nameplate full load current a1 13 21 0,25 0,4 0,4 0,63 a2 14 22 pkzm0-0,16/s00-11120v60hz 044517 pkzm0-0,25/s00-11120v60hz 044526 pkzm0-0,4/s00-11120v60hz 044535 pkzm0-0,63/s00-11120v60hz 044544 pkzm0-1/s00-11120v60hz 044553 pkzm0-1,6/s00-11120v60hz 044562 pkzm0-2,5/s00-11120v60hz 044571 pkzm0-4/s00-11120v60hz 044580 pkzm0-6,3/s00-11120v60hz 044589 pkzm0-10/s00-11120v60hz 044598 · ratings 11a 600 v ac 7½ hp 460 v 10 hp 575 v max · phase failure sensitive and ambient compensated · adjustable thermal trips set to motor flc or nameplate currrent · fixed instantaneous magnetic trip response · open or door mounted handle padlockable with 3 position indication on/off/tripped · finger-safe construction · assembled on clip plate for 35 mm din rail or panel mounting dc operated versions come standard with built-in surge suppressors coil voltage 12 v dc 24vdc 48 v dc 60 v dc 110 v dc 220 v dc circuit diagram t 0,63 1 1 1,6 1,6 2,5 2,5 4 4 6,3 22 150 125 6,3 10 notes 1 world market device iec q ul/csa manual motor protectors motor protector combinations max listed branch circuit protective fuse max listed branch circuit protective breaker adjustable thermal range response curul/csa 3-phase hp ratings rent of magnetic for single phase rating and iec kw trips ratings see pages 08/054 and 08/056[close] |
Page 409 of 649 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |