Page 489 of 649 ![]() |
![]() View extracted text
Page 489 of Current Catalog by Moeller Electric USA09/044 circuit breakers disconnect switches molded case switches molded case circuit breakers and switches undervoltage trips and ground fault modules for type nzm10 na rated actuating voltage us v undervoltage trips undelayed response electrically trip the device open under power loss when supply voltage drops below 35 70 of rated trip coil value and can be used for control interlocking purposes e.g to disconnect the main switch in emergency-stop circuits they are rated for continuous duty undervoltage trips cannot be mounted together with shunt trips type suffix article no when ordered with basic device list price see price list type article no when ordered separately 1 list price see price list d1 ac 24 48 60 110 120 125 130 208 215 220 240 380 415 440 480 500 600 d2 +u-nzm1024vac 036665 +u-nzm1048vac 036667 +u-nzm1060vac 036669 +u-nzm10110-120vac 036671 +u-nzm10125-130vac 036673 +u-nzm10208-215vac 036675 +u-nzm10220-240vac 036677 +u-nzm10380-415vac 036679 +u-nzm10440-480vac 036681 +u-nzm10500vac 036683 +u-nzm10600vac 036686 +u-nzm1024vdc 036689 +u-nzm1048vdc 036691 +u-nzm1060vdc 036693 +u-nzm10110-120vdc 036695 +u-nzm10125-130vdc 036697 +u-nzm10208-215vdc 036699 +u-nzm10220-240vdc 036701 u-nzm1024vac 036666 u-nzm1048vac 036668 u-nzm1060vac 036670 u-nzm10110-120vac 036672 u-nzm10125-130vac 036674 u-nzm10208-215vac 036676 u-nzm10220-240vac 036678 u-nzm10380-415vac 036680 u-nzm10440-480vac 036682 u-nzm10500vac 036684 u-nzm10600vac 036685 u-nzm1024vdc 036690 u-nzm1048vdc 036692 u-nzm1060vdc 036694 u-nzm10110-120vdc 036696 u-nzm10125-130vdc 036698 u-nzm10208-215vdc 036700 u-nzm10220-240vdc 036702 d1 dc 24 48 60 110 120 125 130 208 215 220 240 d2 ground fault trip module no outside power source required ground fault trip current adjustable in steps in 80 100 130 160 200 240 280 320 360 400 a with adjustable delay time tv 0 60 150 200 300 500 750 1000 ms 6.13 6.21 i n 6.14 6.22 module is attached directly to the circuit breaker ground fault trip current is signalled directly to the electronic circuitry module is mounted separately ground fault trip current is signalled directly to a shunt or undervoltage trip via auxiliary contacts notes 1 +tv-nzm10 095126 accessories are field installable tv-nzm10 034811 tv-nzm10/e 034813[close] |
Page 489 of 649 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |