Page 57 of 649 ![]() |
![]() View extracted text
Page 57 of Current Catalog by Moeller Electric USA02/012 02/013 dil r industrial control relays basic relay modules contacts ul/csa general use 600v ac max ul/csa pilot duty rating ul csa iec ce ac operated type article no dil r industrial control relays basic relay modules dc operated type article no price see price list 1 ul csa iec ce price see price list notes industrial control relays electronic timing relays n.o normally open n.c normally closed a circuit symbol a 600 p 300 contact code number and version2 40e 31e 22e coil voltages shown in for other coil voltages see page 02/030 dilr40120v60hz 043753 dilr31120v60hz 043765 dilr22120v60hz 043777 coil voltages shown in for other coil voltages see page 02/030 dilr40-g 24vdc 048537 dilr31-g 24vdc 048532 dilr22-g 24vdc 048526 contact numbers to en 50 011 terminal markings coils to en 50 005 dil r 40 supplied without front plate page 02/025 accessories 1 interface module other accessories version e combinations correspond to en 50 011 and are to be preferred other combinations correspond to en 50 005 page 02/024 02/024 basic relays with positively driven contacts1 4 n.o 15 3 n.o 2 n.o 1 n.c 2 n.c a1 13 23 33 43 a2 14 24 34 44 a1 13 21 33 43 a2 14 22 34 44 a1 13 21 31 43 a2 14 22 32 44 auxiliary contact modules with positively driven 2-pole 2 n.c 15 contacts1 a 600 p 300 51 61 42e 33 24 02dil 098145 11dil 010345 20dil 012718 04dil 015091 13dil 017464 22dil 019837 31dil 010752 40dil 022210 02dil 098145 11dil 010345 20dil 012718 04dil 015091 13dil 017464 22dil 019837 31dil 010752 40dil 022210 52 62 contact code number the contact code number provides useful information of the relay it refers to the total number of n.o contacts 1st digit and n.c contacts 2nd digit found on the device adding both digits will result in the total number of contacts example dilr40 04dil 4 n.o 4 n.c contacts for a total of eight contacts some contact combinations are preferred when used in configurations conforming to european norms en standards these are denoted by the letter e in the contact code number and are in accordance with din en 50 011 all other combinations without the letter e are in accordance with din en 50 005 in the example above the combination of dilr40 04dil yields a relay with type e configuration 44e 1 n.o 1 n.c 53 61 51e 42 33 54 62 2 n.o 53 63 60e 51 42 54 64 4-pole 4 n.c 15 a 600 p 300 51 61 71 81 44e 35 26 52 62 72 82 1 n.o 3 n.c 53 61 71 81 53e 44 35 54 62 72 82 2 n.o 2 n.c 53 61 71 83 62e 53 44 54 62 72 84 3 n.o 1 n.c 53 61 73 83 71e 62 53 54 62 74 84 4 n.o 53 63 73 83 80e 71 62 54 64 74 84 pneumatic timer module convertible time ranges of 0.2 30 s and 20 180 s on-delayed 1 n.o 1 n.c 10 a 300 55 67 56 68 51 42 33 tpe11dil 002279 tpe11dil 002279 version e combinations correspond to en 50 011 and are to be preferred other combinations correspond to en 50 005 off-delayed 1 n.o 1 n.c 10 a 300 65 57 51 42 33 tpd11dil 002280 tpd11dil 002280 66 58 mechanical latching module e1 40e 31e 22e vdil120v60hz 043822 v-gdil24vdc 048562 maximum impulse duration for dc energization 200ms e2 notes 1 2 positively driven contacts zh 1/457 specification standard n.o and n.c contacts can never be closed simultaneously by definition overlapping contacts i.e em early make and lb late break cannot be positively driven refer to explanation in notes column industrial control relays electronic timing relays[close] |
Page 57 of 649 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Moeller Electric USA. |