Catalog: Current Catalog
Company/Brand: Moeller Electric USA
|
| | 02/044 dil er dil r industrial control relays technical data dil er ... dil e dil r dil industrial control relays electronic timing relays ... 50 hz and dual-voltage coil 50 hz 60 hz pick-up pick-up pick-up pick-up x uc x uc x uc ... 0,7 1,3 0,8 1,1 0,85 1,1 0,85 1,1 pull-in sealing dual-frequency coil v 50/60 ... hz at 50 hz v 50/60 hz at 60 hz pull-in sealing pull-in sealing pull-in ...
|
| | tp timer modules v latching modules vs interface modules technical data tpe 11 dil tpd ... 2 dil ets 4-vs 3 unlatching unlatching pick-up unlatching x uc x uc x uc x uc ... ,8 1,1 0,75 1,25 0,85 1,2 pull-in sealing pull-in sealing va/w va/w w ... repetition accuracy time deviation in relation to ambient temperature based ... dc or three-phase bridge rectifier industrial control relays electronic timing relays ...
|
| | voltage tolerance ac operated 50/60 hz pick-up dc operated when taken directly from ... mains or transformer 1000 va pick-up power consumption ac operated 50/60 hz ... pull-in sealing dc operated pull-in sealing duty factor max operating ... 01 u 0,025 0,1 70 4 501 ms ms etr 4-51 industrial control relays electronic timing relays ...
|
| | with ie to ac-3/400 v magnet systems pick-up and drop-out values ac operated single- ... hz v 50/60 hz at 60 hz dc operated 2 pull-in sealing duty factor switching times at ... 8 8 4 3 2,5 2,5 2,5 1,5 0,3 3,5 0,7 pick-up pick-up pick-up x uc x uc x uc 0,8 1, ... 0,8 1,1 0,85 1,1 0,85 1,1 pull-in sealing pick-up sealing pick-up sealing ...
|
| | 22 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 pick-up pull-in sealing x us w ms ms df 0,85 ... protectors motor protector combinations pick-up drop-out pick-up drop-out pull-in ... sealing pull-in sealing pull-in sealing x us x us x us x us va/w va/w ...
|
| | nhi nhi-e agm nhi s hi 10 8 1 fault in 1 e150 for nhi-e pkz0 1 for nhi-e pkz0 ... -time operation 5 s power consumption pull-in ac sealing ac pull-in dc sealing dc ... undervoltage trips pick-up voltage drop-out voltage power ... consumption pull-in ac sealing ac fault probability hf ... x us va va w w x us x us va va please inquire 10 0,75 2,5 18 14 42 480 24 250 ... tripping time of the motor protector in relation to the response current the ... specific characteristics for each individual setting range are available on request ... theses characteristics in 55 x 75 mm format are self-adhesive and ... for this application the data has been independently verified by the german ptb testing ...
|