Catalog: Current Catalog
Company/Brand: Moeller Electric USA
price of a circuit breaker in Current Catalog by Moeller Electric USA
relays thermistor tripping units circuit diagram amps ze overload relays ul ... 6 2 4 6 n.o n.c for use with max 600 v ac a max 600 v ac 2 a 97 95 1 1 dilem 1 1 ... ze-12 3 014752 1 when using dilem and ze a distance of at least 5 mm should ... relays mounted side by side 2 max 480v ac for type ze 3 ul/csa only short-circuit ... protection the maximum admissible fuse for the contactor must be observed ... -10 069670 z00-16 072043 z00-24 074416 accessories 1 contactors 2 bases accessories page ... relays thermistor tripping units adjustable setting range motor full load current ... auxiliary contacts short-circuit protection by fuses by circuit breaker ...

trip response from 2 to 10 seconds ambient compensated bi-metallic overload ... sensitive to iec/en 60947 manual automatic reset button built-in no and nc ... auxiliary contact direct mount ze thermal ... relays for dilem miniature contactors auxiliary contacts adjustable setting range 0.1 ... 1.6 2.4 2.4 4 46 69 9 12 short-circuit protection max 600v ac fuses a 1 1 1 1 ... nc 1 1 1 1 1 1 1 1 1 1 1 for use with circuit breaker a 15 15 15 15 15 15 15 15 15 15 ... ze-1,6 ze-2,4 ze-4 ze-6 ze-9 ze-12 type article number 014263 014285 014300 014333 ... 014479 014518 014565 014708 014752 price see green pages when using dilem and ze ... a distance of at least 5mm should be maintained between ...

trip response from 2 to 10 seconds ambient compensated bi-metallic overload ... sensitive to iec/en 60947 manual automatic reset button built-in no and nc ... auxiliary contact direct mount zb thermal ... relays for dilm7 dilm32 contactors auxiliary contacts overload relay adjustable ... 6 6 10 10 16 16 24 24 32 short-circuit protection max 600v ac for use with ... fuses a 1 1 1 1 3 dilm7 dilm12 diulm7 ... 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 circuit breaker a 25 25 25 25 25 25 25 25 25 25 ... zb32-6 zb32-10 zb32-16 zb32-24 zb32-32 article number 278431 278432 278433 278434 ... 278450 278451 278452 278453 278454 price see green pages observe the maximum ... permissible fuse of the contactor with direct device ...

trip response from 2 to 10 seconds ambient compensated bi-metallic overload ... sensitive to iec/en 60947 manual automatic reset button built-in no and nc ... auxiliary contact direct mount zb thermal ... relays for dilm40 dilm150 contactors auxiliary contacts overload relay adjustable ... 70 70 100 95 125 120 142 short-circuit protection max 600v ac for use with ... fuses a 40 60 dilm40 to dilm65 diulm40 to ... 1 1 1 1 1 1 nc 1 1 1 1 1 1 1 1 1 1 1 1 circuit breaker a 40 60 90 125 150 150 125 200 ... zb65-65 zb150-35 zb150-50 zb150-70 type article number 278455 278456 278457 278458 ... 278462 278463 278464 278465 278466 price see green pages zb150-100 zb150-125 ... observe the maximum permissible fuse of the contactor with direct device ...

trip response from 2 to 10 seconds ambient compensated bi-metallic overload ... sensitive to iec/en 60947 manual automatic reset button built-in no and nc ... auxiliary contact direct or separate mount z5 ... relays for dilm185 dilm250 contactors auxiliary contacts overload relay adjustable ... 125 120 160 160 220 200 250 short-circuit protection max 600v ac for use with ... fuses a 250 400 class j dilm185 to dilm250 ... class l no 1 1 1 1 1 1 nc 1 1 1 1 1 1 circuit breaker a 250 400 500 600 800 600 type ... z5-160/ff250 z5-220/ff250 z5-250/ff250 article number 210070 210071 210072 210073 ... 210074 210075 price see green pages observe the maximum ... permissible fuse of the contactor with direct device ...

manual motor protectors ul/csa short-circuit current rating 600 v ac max listed ... branch circuit protective fuse a max listed branch circuit protective ... breaker a 600 adjustable response current thermal range of ... pkz0 manual motor protectors type article no list price see price list notes ul ... combinations for single phase rating and iec kw ratings see pages 08/054 and 08/ ... 056 a 0,1 0,16 0,16 0,25 a 2,2 3,5 5,6 8,8 14 22 35 56 88 140 224 ... in this range select motor protector in accordance with the motor nameplate full load ... 8 manual motor protectors 1 type 1 and 2 coordination 50 600 l t 0,25 0,4 ...

type pkzm 0 se00 ul/csa short-circuit current rating rms sym 600 v ac ka ... combinations type pkzm 0 se00 type article no list price see price list notes 6 ul ... motor protector combinations 4 5 3 aaaa 200 v hp 230 v hp 460 v hp 575 v hp ... shown in for other coil voltages a page 08/043 600 0,1 0,16 0,16 0,25 ... in this range select motor protector in accordance with the motor nameplate full load ... current a1 13 21 0,25 0,4 0,4 0,63 a2 14 22 pkzm0-0,16/se00-11120v60h z ... /se00-11120v60hz 058790 the pkzm 0 se00 and pkzm 0 s00 are motor protector ... combinations made up of pkzm 0 manual motor protectors and ... these motor protector combinations are ul listed and csa certified as ...

pkz 0 motor protectors mvs mounting and wiring accessory kits for motor starter ... combinations for use with type article no list price see price list mvs kits ... mvs-d11 031166 includes mounting plate and finger-safe wiring harness to ... accommodate fvnr motor starter combinations ... consisting of pkzm 0 motor protectors and dil m magnetic contactors in various ... csa certified for group installations and high fault short circuit current ... ratings shown at bottom of this page in association with moeller electric components ... wide with continuous top-hat rail top and bottom top-hat rail adapter for motor ... top-hat rail extension for top-hat rail adapter all mvs-c electromechanical link ...

08/026 08/027 manual motor protectors and magnetic motor protector combinations ... csa iec ce manual motor protectors and magnetic motor protector combinations ... system pkz 2 type article no coil voltages shown in for other ... coil voltages a page 08/047 5 ul csa iec ce manual ... combinations for single phase ratings and iec kw rating a page 08/065 200 v hp ... 230 v hp 460 v hp 575 v hp see price list 3 9 7 480 v ac 600 v ac 6 aaaa ... in this range select motor protector in accordance with the ½ motor nameplate full load ... /zm-32/s120v60hz 063550 the pkz2/zm is a 3-phase thermal magnetic motor ... protective device incorporating adjustable bimetal trips for motor overload ...

09/010 circuit breakers disconnect switches molded case ... csa iec en 60 947-2 ce inverse time circuit breakers 150a 600v ac thermal-magnetic ... type nzm 7 na inverse time circuit breakers 150a 600v ac thermal-magnetic type nzm7 ... ce normal interrupting capacity 25 ka at 480 v 50/60 hz 14 ka at 600 v 50/60 hz ... list price see price list ka at 480 v 50/60 hz 22 ka at 600 v 50/60 hz ... fuseless current-limiting circuit breaker type article no list price see price ... list notes continuous current rating iu a fixed thermal setting magnetic trip ... setting for instantaneous response a ul/csa interrupting ratings ac 60hz ka ...

09/012 circuit breakers disconnect switches molded case ... csa iec en 60 947-2 ce inverse time circuit breakers 150a 600v ac thermal-magnetic ... capacity continuous current rating iu a adjustable thermal setting magnetic ... trip setting for instantaneous response a ul/csa interrupting ratings ac 60hz ka ... 600v molded case switches 200a 600v ac ul csa iec en 60 947-3 ce 25 ka at ... 480 v 50/60 hz 14 ka at 600 v 50/60 hz type article no list ... price see price list ampere rating type article no notes list price see price list 4 a ... wire terminals for cable connection a with adjustable thermal setting and ...

09/014 circuit breakers disconnect switches molded case ... switches 09/013 molded case circuit breakers and switches auxiliary contacts for ... nzm7 na contact sequence type suffix article no when ordering with basic device list ... price see price list molded case circuit breakers and switches auxiliary ... contacts for type nzm7 na type article no when ordering separately 1 list ... price see price list nhi standard auxiliary contact simultaneous switching with the ... signalling interlocking or switching auxiliary contacts such as a control circuit 1 ... contacts can be snap-mounted into the circuit breaker or molded case switch 1.14 1.11 ...

09/016 circuit breakers disconnect switches molded case ... switches 09/017 molded case circuit breakers and switches shunt trips for type nzm7 ... na contact diagram rated actuating voltageus type suffix article no when ... ordering with basic device list price see price list molded case circuit ... breakers and switches shunt trips for type nzm7 na ... type article no when ordering separately 1 list ... price see price list v shunt trip shunt trips are ... to electrically trip the device from a remote location the a nzm 7 series is ... with undervoltage trips without auxiliary contacts c1 ac/dc 2 12 24 48 60 110 ... 215 220 240 380 415 440 480 c2 +a-nzm712v 027640 +a-nzm724v 027641 +a-nzm748v ...

09/018 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and switches undervoltage trips for type ... nzm7 na contact diagram rated actuating voltage us v undervoltage trip ... when supply voltage drops below 35 70 of rated trip coil value and can be used ... the main switch in emergency-stop circuits they are rated for continuous duty ... together with shunt trips type suffix article no when ordered with basic device list ... price see price list type article no when ordered separately 1 list price ... see price list d1 ac 24 48 60 110 120 125 130 208 215 ... 120 125 notes 1 undervoltage trips are field-installable auxiliary contacts ...

09/020 circuit breakers disconnect switches molded case ... switches 09/021 molded case circuit breakers and switches remote control drive for ... type nzm7 na rated actuating voltage us v remote control drive ... operates the nzm 7 circuit breaker or molded case switch electrically from ... a remote location switching times on ... 100ms off 100ms local manual operation of the switch possible ac/dc ac/dc dc dc ... 027632 +r-nzm748-60v 027633 type suffix article no when ordered with basic device list ... price see price list molded case circuit breakers and switches remote control ... drive for type nzm7 na type article no when ordered separately 1 list price ...

09/022 circuit breakers disconnect switches molded case ... switches 09/023 molded case circuit breakers and switches accessories for type nzm7 ... na type suffix article no when ordered with basic device list ... price see price list molded case circuit breakers and switches accessories for ... type nzm7 na type article no when ordered separately list price ... see price list insulating frame for door cutout ... fits around the cutout area of the panel door through which the toggle ... mechanism on the front of the switch protrudes degree of ... rotary drive mechanism converts on and off switching from a toggle motion to a ...

09/024 circuit breakers disconnect switches molded case ... switches 09/025 molded case circuit breakers and switches accessories for type nzm7 ... na type suffix article no when ordered with basic device side ... wall operator enables actuation of the switch from its left or right side ... as opposed to the front for operation on ... the left +swa-nzm7-l 054520 list price see price list molded case circuit ... breakers and switches accessories for type nzm7 na type article no when ... ordered separately list price see price list swa-nzm7-l 054519 the swa shifts ... the rotary movement of the switch by 90° and permits the ... rotary handle to mount and actuate the switch from the side of the control ...

09/026 circuit breakers disconnect switches molded case ... switches 09/027 molded case circuit breakers and switches accessories for type nzm7 ... na type suffix article no when ordered with basic device list ... price see price list molded case circuit breakers and switches accessories for ... type nzm7 na type article no when ordered separately list price ... see price list mechanical interlock for ... interlocking two type nzm7 circuit breakers or molded-case switches of the same ... mechansim for simultaneous operation of 2 molded case switches mounted side by ... side using a rotary drive k 2-p7 054517 extension ... with shunt or undervoltage trip not for circuit breaker kv 2-nzm7 200468 clip plate ...

09/036 circuit breakers disconnect switches molded case ... switches 09/037 inverse time circuit breakers 600 a 600 v ac solid state trip type ... ce normal interrupting capacity 42 ka at 480 v 50/60 hz 35 ka at 600 v 50/60 hz ... type article no list price see price list inverse time circuit breakers 600 ... a 600 v ac solid state trip type nzm 10 na medium ... interrupting capacity 65 ka at 480 v 50/60 hz 42 ka at 600 v 50/60 hz ... type article no list price see price list ul csa iec/en 60 947-2 ce notes ... long time response current setting ir a nzm 10 zmva na with fixed long time ... 300 350 400 500 600 nzm 10 zmv na with adjustable long time response settings with short- ...

09/038 circuit breakers disconnect switches molded case ... switches molded case circuit breakers instantaneous trip type 600a nzm10 zm ... frame continuous rating current rating a solid state instantaneous trip circuit ... breakers 600v ac ul/csa normal level short-circuit ... rating type article no list price se price list notes ul recognized ul 489 and csa ... c22.2 nr 5.1 instantaneous trip type circuit breaker with an adjustable trip ... function per nec and cec they provide motor short circuit ... protection as part of a listed combination motor controller ... motor overload protection short-circuit interrupting ratings are therefore ...

09/040 circuit breakers disconnect switches molded case ... switches 09/041 inverse time circuit breaker components 600 a 600 vac type nzm 10 na ... modules nzm10 inverse time molded case circuit breakers are made up of a switch block ... and a protective trip module switch blocks ... and trip modules can be ordered separately ... and combined per the charts and columns shown here to suit any ... particular application refer to chart at bottom of opposite page for resulting ... long time response current setting ir a adjustable instantaneous pick-up ... csa iec en 60 947-2 ce inverse time circuit breaker components 600 a 600 v ac type ...

09/042 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and switches auxiliary contacts signalling ... nzm10 na contact diagram type suffix article no when ordered with basic device nhi ... standard auxiliary contact switching simultaneously with ... signalling interlocking or switching auxiliary circuits such as a control circuit 1.13 ... 1.21 1.43 1.31 list price see price list type article no when ordered ... separately 1 list price see price list +nhi-nzm10 034798 nhi-nzm10 034943 ... 1.14 1.22 1.44 1.32 vhi early-make auxiliary contact typically used for powering up ... the undervoltage trip prior to closing of main contacts and for control circuit ...

09/044 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and switches undervoltage trips and ground ... fault modules for type nzm10 na rated actuating voltage us v undervoltage trips ... when supply voltage drops below 35 70 of rated trip coil value and can be used ... the main switch in emergency-stop circuits they are rated for continuous duty ... together with shunt trips type suffix article no when ordered with basic device list ... price see price list type article no when ordered separately 1 list price ... see price list d1 ac 24 48 60 110 120 125 130 208 215 ... required ground fault trip current adjustable in steps in 80 100 130 160 200 240 280 ...

09/045 molded case circuit breakers and switches remote control drives and ... accessories for type nzm10 na rated actuating voltage us v remote control drive to be ... mounted on top of circuit breakers and molded case switches switching times on ... 60 ms off 30 ms manual switching possible type ... suffix article no when ordering with basic device type ... article no when ordering separately 1 list ... price see price list l1l 0 i h1 71 72 75 70 r-nzm 10 ... 0 s h1 70 71 72 75 r-nzm 10 74 nl l2 ac 110 220 +r-nzm10110-120vac 027622 +r- ... r-nzm 10 74 nl l2 3-wire control with automatic reset to the off position after the ... pushbutton operator for manual on-off switching of encapsulated nzm10 ...

09/046 circuit breakers disconnect switches molded case ... switches 09/047 molded case circuit breakers and switches accessories for type nzm10 ... na type suffix article no when ordered with basic device ... toggle switch interlock permits the off position of the toggle operator to be ... from the enclosure provides degree of protection ip 40 +rt-nzm10 094927 list ... price see price list molded case circuit breakers and switches accessories for ... nzm10 na type article no when ordered separately 1 list price ... see price list svb-nzm10 034948 rt-nzm10 034828 ... affixed from the rear with screws can be ... rotary drive mechanism converts on and off switching from a vertical togle ...

09/051 molded case circuit breakers and switches terminals for type nzm10 na ... current conductor cross-section range and material type suffix article no when ... ordered with basic device 1 list price see price list type article no ... separately for field mounting list price see price list a terminals supplied as ... · 1 set of 3 terminals when ordered with basic ... supplied with terminal cover 500 2 x awg 3/0 250 kcmil cu only +k2x120-nzm10-o ... supplied with 3 terminal covers h-nzm10 and an insulating plate onto which the ... circuit breaker is mounted 600 2 x awg 2 500 kcmil cu/al +k2x240ip-nzm10-o ... with 1 terminal cover type h-nzm10 and an insulating plate onto which the circuit ...

09/052 circuit breakers disconnect switches molded case ... switches molded case circuit breakers instantaneous trip type nzmh4 obi ... type article no continuous current rating a ... instantaneous trip circuit breakers frame rated at 18a line and load field- ... terminals for cable connection supplied as standard accessories handles ... accessories adjustable magnetic trip range a list price see ... price list notes ul csa page 09/056 09/054 ... up to 480v ac ul/csa 2.1 3.7 6.6 10 12 15 18 6 12 11 ... 005472 type nzmh4 obi molded case circuit breakers are ul recognized ul 489 and ... 22.2 nr 5.1 instantaneous trip type circuit breakers with an adjustable magnetic ...

disconnect switches type nzmh4 cna adjustable adjustable thermal range magnetic trip ... for motor over range load protection a nzm4 cna motor disconnect switch frame ... rated at 80a line and load fieldwiring terminals for cable ... connection supplied as standard a motor rating type article no ul csa ... iec en 60 947-2 list price see price list notes 200v hp 230v hp 460v hp 575v ... hp accessories handles accessories page 09/056 09/054 4-6 6 10 10 16 16 ... 062163 nzmh4 cna disconnect switches are ul recognized ul 508 and csa certified ... 22.2 nr 14 as 3 pole hp rated manual motor ... trips for motor overload protection an adjustable dial on the front of the switch can be ...

09/054 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches auxiliary contacts ... open n.c normally closed n.o standard auxiliary contacts 2 n.c 2 +nhi22-nzm4/6-na ... 082860 combination possibilities of auxiliary contacts nhi vhi ahi rhi ... 1 +vhi-nzmh4-na 082864 type suffix article no when ordering with basic device list ... price see price list notes vhi ahi and rhi are supplied as 1 n.o and 1 n.c ... contact set but can be field modified as 2 n.o or 2 n.c early-make auxiliary ... contacts 1 handle-operated early-make auxiliary contacts 1 1 +ahi-nzmh4-na 082865 trip- ...

09/057 molded case circuit breakers and disconnect switches accessories for ... nzmh4 color of handle for use with type suffix article ... no when ordering with basic device type article no when ordering separately 1 list ... price see price list handle for open or panel mounted ... for cover/door interlocking degree of protection ul/nema 3r 12 ip 55 door ... handle for front mounting in doors and covers can be locked in the off ... interlocking supplied standard set in off position can be field modified for ... on position 3 distinct handle positions off tripped on gray black for emergency- ... mm extends shaft length by 266 mm can also be used with mechanical interlock red- ...

circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches auxiliary contacts ... for type nzmh4 type suffix article no when ordered with basic device ... provides shock hazard protection in the area of the field wiring power terminals can ... be used at top or bottom one cover per side ... requirement on the supply side of main disconnect switches to provide ... protection against accidental contact with line side feed +h-nzmh4 ... clip for mounting nzmh4 devices on a din rail rail conforming to the ... en 50 022 +c-nzmh4 058364 notes 1 type article no when ordered separately1 list price ... see price list h-nzmh4 014880 c-nzmh4 034534 ...

09/061 molded case circuit breakers instantaneous trip 125a type nzmh6b ... zm6 obi continuous current rating a standard interrupting rating up to 600v ... ac frame rated at 125a line and load field-wiring terminals for cable ... connection supplied as standard adjustable magnetic trip range a accessories ... handles accessories page 09/066 09/064 type without handle ... article no list price see price list notes 0.6 1.2 2.1 3.7 6.6 6.6 12 ... fault interrupting rating up to 600v ac frame rated at 125a line and load field ... terminals for cable connection supplied as standard 2.6 5 4-8 6 -12 10 20 16 32 ...

09/062 circuit breakers disconnect switches molded case ... switches type nzm h6b zm6 cna adjustable thermal trip range adjustable magnetic ... trip range maximum hp rating 3 phase at type without handle article no 200v ... hp hp hp ul csa iec en 60 947-2 list price see price list notes a a standard short ... circuit rating frame rated at 125a line and load field-wiring ... terminals for cable connection supplied as standard 15 25 160 320 25 40 40 63 ... 260 500 400 800 600 1200 1000 2000 accessories handles accessories page 09/066 09/064 ... -cna 048207 nzm6b-160/zm6-125-2000-cn a 067191 with optional lower magnetic ...

09/063 motor disconnect switches 150 a type n6 cna continuous current rating a ... ul/csa short circuit withstand rating at 600v ac 10 ka rms sym frame rated at ... 150a line and load field-wiring terminals for cable ... connection supplied as standard 63 100 150 20 30 40 25 40 60 ... -cna 095656 maximum hp rating 3 phase at 200v 230v 460v 575v hp hp hp hp type ... without handle article no list price see price list ul csa iec en 60 947- ... 3 notes accessories handles accessories page 09/066 09/064 n6 cna disconnect ... switches are ul recognized ul 508 and csa certified c22.2 nr 14 as 3 pole hp ... rated non-automatic manual motor disconnects without any ...

09/064 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches auxiliary contacts ... n.c normally closed n.o n.c standard auxiliary contacts 2 2 type suffix article no ... when ordering with basic device list price see price list notes +nhi22-nzm4/6-na ... 082860 combination possibilities of auxiliary contacts nhi vhi ahi rhi ... indicate incompatibility early-make auxiliary contacts 2 form c change over contacts ... +vhi002-nzm6-na 082861 auxiliary contacts must be ordered with the ... device handle-operated early-make auxiliary contacts 2 form c change over contacts ...

09/066 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches accessories for ... nzmh6b color of handle for use with type suffix article ... no when ordering with basic device type article no when ordering separately 1 list ... price see price list handle for open or panel mounted ... 064370 h6u 093191 h6u-sw 034176 degree of protection ul/nema 3r 12 ip 55 door ... handle for front mounting in doors and covers can be locked in the off ... interlocking supplied standard set in off position can be field modified for ... on position 3 distinct handle positions off tripped on gray black for emergency- ...

09/071 molded case circuit breakers instantaneous trip 250a type nzmh9 zm9 ... obi continuous current rating a standard interrupting rating up to 600v ... ac frame rated at 250a line and load fieldwiring terminals for cable ... connection supplied as standard adjustable magnetic trip range 1 a accessories ... handles accessories page 09/076 09/074 type without handle ... article no list price see price list notes 63 100 160 200 250 400 800 ... fault interrupting rating up to 600v ac frame rated at 250a line and load ... terminals for cable connection supplied as standard nzm9-250/zm9 obi-cna and nzmh9 ...

09/072 circuit breakers disconnect switches molded case ... magnetic trip maximum hp rating 3 phase at type without handle ul csa iec en 60 ... 947-2 list price notes article no a a 200v 230v 460v 575v hp hp hp hp see ... price list standard short circuit rating frame rated at 250a line and ... terminals for cable connection supplied as standard 63 100 600 1200 100 160 160 ... 250 1000 2000 1600 2400 1600 2400 accessories handles accessories page 09/076 09/074 ... /zm9-250-2000-cna 047683 nzm9 zm9 cna and nzmh9 zm9 cna disconnect switches are ... ul recognized ul 508 and csa certified c22.2 nr 14 3-pole hp ...

09/073 motor disconnect switches 250 a type n9 cna continuous current rating ... maximum hp rating 3 phase at type without handle article no list ... price see price list notes ul csa iec en 60 947-3 a ... ul/csa short circuit rating at 600v ac 10 ka rms sym frame rated at 250a line ... and load field-wiring terminals for cable ... connection supplied as standard 200v 230v 460v 575v hp hp hp ... hp accessories handles accessories page 09/076 09/074 250 60 75 150 200 n9 ... -cna 031587 n9 cna disconnect switches are ul recognized ul 508 and csa certified ... c22.2 nr 14 as 3 pole hp rated non-automatic manual motor disconnects without any ...

09/074 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches auxiliary contacts ... open n.c normally closed type suffix article no when ordering with basic device list ... price see price list notes n.o standard auxiliary ... -nzm9 091579 combination possibilities of auxiliary contacts nhi vhi ahi rhi ... indicate incompatibility early-make auxiliary contacts 2 form c change over contacts ... auxiliary contacts must be ordered with the ... -nzm9 093952 handle-operated early-make auxiliary contacts 2 form c change over contacts ... +ahi002-nzm9 044120 trip-indicating auxiliary contacts 2 form c change over contacts ...

09/075 molded case circuit breakers and disconnect switches voltage trips motor ... rated control voltage type suffix article no to be ordered with device only list ... price see price list notes v/hz shunt trips 100 ... continuous duty rating 53 51 if desired automatic disconnection of the shunt trip coil ... can be achieved by using the nhi auxiliary contact in series with the coil shunt ... together with undervoltage trips ac 120/60 208/60 240/60 480/60 600/60 dc ... -delayed continuous duty rating 52 51 +a-nzm9120v60hz 057267 +a-nzm9208v60hz 057750 +a- ... nzm9240v60hz 057982 +a-nzm9480v60hz 059333 +a-nzm9600v60hz 059641 +a- ... nzm924vdc 060081 shunt trips are typically used to electrically trip the ...

09/076 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches accessories for ... nzmh9 color of handle for use with type suffix article ... no when ordering with basic device type article no when ordering separately 1 list ... price see price list handle for open or panel mounted ... 065009 h9u 017256 h9u-sw 034175 degree of protection ul/nema 3r 12 ip 55 door ... handle for front mounting in doors and covers can be locked in the off ... interlocking supplied standard set in off position can be field modified for ... on position 3 distinct handle positions off tripped on gray black for emergency- ...

09/081 motor disconnect switches 1200 a type n12 cna continuous current rating ... maximum hp rating 3 phase at 200v 230v 460v hp hp hp 575v hp type ... without handle article no a frame rated at 1200a line and load fieldwiring ... terminals for cable connection supplied as standard 1 600 800 1000 1200 200 250 ... 081517 2 ul csa iec en 60 947-3 list price see price list notes accessories ... handles accessories page 09/084 09/082 n12 cna disconnect ... switches are ul recognized ul 508 and csa certified c22.2 nr 14 as 3 pole hp ... rated non-automatic manual motor disconnects without any ... overload or short circuit tripping elements their switching ...

09/082 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches auxiliary contacts ... open n.c normally closed n.o standard auxiliary contacts 1 2 n.c 2 +nhi22-nzm12 013272 ... type suffix article no when ordering with basic device list ... price see price list notes combination possibilities of ... auxiliary contacts:1 nhi vhi ahi rhi n12 nzm12 f f ... standard equipment 1 early-make auxiliary contacts 2 1 +vhi21-nzm12 015645 handle ... -operated early-make auxiliary contacts 2 1 +ahi21-nzm12 018018 nhi22- ... nzm12 auxiliary contact comes standard with all ...

09/083 molded case circuit breakers and disconnect switches voltage trips motor ... suffix to be ordered with device only article no list price see price list notes v/hz ... trips 53 51 100 continuous duty rating ac 120/60 208/60 240/60 480/60 600/60 +a- ... nzm12120v60hz 050365 +a-nzm12208v60hz 050482 +a-nzm12240v60hz 050810 +a- ... nzm12480v60hz 051098 +a-nzm12600v60hz 052204 +a-nzm1224vdc 052324 shunt trips ... are typically used to electrically trip the ... device from a remote location automatic disconnection of the shunt trip can be ... achieved by using the nhi auxiliary contact ahead in series with the shunt ... operation requires coil clearing auxiliary contact +nhi22-nzm12 u 51 ac 120/60 ...

09/084 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and disconnect switches accessories for ... nzm12 color of handle for use with type suffix article ... no when ordered with basic device type article no when ordered separately 1 list price ... see price list handle for open or panel mounted ... h12u 052850 h12u-sw 034173 degree of protection ul/nema 3r 12 ip 55 door ... handle for front mounting in doors and covers can be locked in the off ... interlocking supplied standard set in off position can be field modified for ... on position 3 distinct handle positions off tripped on gray black for emergency- ... only one extension shaft permitted can also be used with mechanical interlock nzm12 ...

09/086 circuit breakers disconnect switches molded case ... switches molded case circuit breakers and switches accessories for nzm12 type ... suffix article no when ordered with basic device ... provides shock hazard protection in the area of the field wiring power terminals can ... be used at top or bottom one cover per side ... requirement on the supply side of main disconnect switches to provide ... protection against accidental contact with line side feed +h-nzm12 ... 065510 test unit for nzm12 circuit breakers supply terminal voltage can be selected ... verify that the long time instantaneous and short time delayed tripping ... characteristics of the circuit breaker are operating as per preset values various ...

faz branch circuit breakers trip characteristic c ul approved ... ul489 and csa certified csa c22.2 no 5-02 as ... branch circuit breakers interrupting capacity 10ka ul/csa 15ka ... trip characteristic c response time of instantaneous trip 5 10 x in current ... type c characteristics suitable for applications where medium levels of inrush current ... are expected instantaneous trip is 5 to 10 ... x rating of device in applications include small transformers lighting ... pilot devices control circuits and coils medium magnetic trip point trip ... 1 pole 2 poles 3 poles rated current in a 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 ...

faz branch circuit breakers trip characteristic d ul approved ... ul489 and csa certified csa c22.2 no 5-02 as ... branch circuit breakers interrupting capacity 10ka ul/csa 15ka ... trip characteristic d response time of instantaneous trip 10 20 x in current ... type d characteristics suitable for applications where high levels of inrush current are ... instantaneous trip is 10 to 20 x rating of device in the high magnetic trip point ... nuisance tripping in high inductive applications such as motors transformers and power ... 1 pole 2 poles 3 poles rated current in a 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 ... faz-d32/1-na faz-d35/1-na faz-d40/1-na price type faz-d0,5/2-na faz-d1/2-na faz-d1,5 ...

faz branch circuit breakers ring tongue trip characteristic c ... ul approved ul489 and csa certified csa c22.2 no 5-02 as ... branch circuit breakers connections for ring-tongue terminals ... trip characteristic c response time of instantaneous trip 5 10 x in current ... type c characteristics suitable for applications where medium levels of inrush current ... are expected instantaneous trip is 5 to 10 ... x rating of device in applications include small transformers lighting ... pilot devices control circuits and coils medium magnetic trip point trip ... 1 pole 2 poles 3 poles rated current in a 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 ... faz-c32/1-rt faz-c35/1-rt faz-c40/1-rt price type faz-c0,5/2-rt faz-c1/2-rt faz-c1,5 ...

faz branch circuit breakers ring tongue trip characteristic d ... ul approved ul489 and csa certified csa c22.2 no 5-02 as ... branch circuit breakers connections for ring-tongue terminals ... trip characteristic d response time of instantaneous trip 10 20 x in current ... type d characteristics suitable for applications where high levels of inrush current are ... instantaneous trip is 10 to 20 x rating of device in the high magnetic trip point ... nuisance tripping in high inductive applications such as motors transformers and power ... 1 pole 2 poles 3 poles rated current in a 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 ... faz-d32/1-rt faz-d35/1-rt faz-d40/1-rt price type faz-d0,5/2-rt faz-d1/2-rt faz-d1,5 ...

faz branch circuit breakers accessories bus bar system bus bar number of poles ... per device 1 number of terminals 6 12 18 6 rated operational ... current a 80 a type z-sv/ul-16/1p-1te/6 z-sv/ul-16/1p- ... -sv/ul-16/1p-1te/18 z-sv/ul-16/2p-2te/6 price 2 12 18 6 80a z-sv/ul-16/2p-2te/12 z-sv ... contact your moeller representative for availability incoming supply terminals terminal ... description type price extension terminal accommodates ... conductors up to 25 mm2 awg 4 finger-safe connection z-ek-35/ul ... for conductors up to 50 mm2 awg 1/0 finger-safe connection to z-sv/ul ... contact your moeller representative for availability www.moellerusa.net www.moeller.ca ...

slightly inductive loads response time of instantaneous trip 3 5 x in current ... rating ul recognized and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 ... type b characteristics suitable for applications where protection against low level ... short circuit faults in control wiring is desired ... trip is 3 to 5 x continuous rating of device in applications include plc ... wiring business equipment lighting appliances and some motors low magnetic trip point ... poles 3 poles 4 poles rated current in a 6 8 10 12 13 15 16 20 25 32 40 50 63 ... faz-b6/1 faz-b8/1 type price faz-b6/2 faz-b8/2 type price faz-b6/3 ...

slightly inductive loads response time of instantaneous trip 3 5 x in current ... rating ul recognized and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 ... type b characteristics suitable for applications where protection against low level ... short circuit faults in control wiring is desired ... trip is 3 to 5 x continuous rating of device in applications include plc ... wiring business equipment lighting appliances and some motors low magnetic trip point ... 3 poles neutral rated current in a 6 8 10 12 13 15 16 20 25 32 40 50 63 ... b32/1n faz-b40/1n faz-b50/1n faz-b63/1n price type faz-b6/3n faz-b8/3n faz-b10/3n faz ...

for inductive loads response time of instantaneous trip 5 10 x in current ... rating ul recognized and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 ... type c characteristics suitable for applications where medium levels of inrush current ... are expected instantaneous trip is 5 to 10 ... x rating of device in applications include small transformers lighting ... pilot devices control circuits and coils medium magnetic trip point trip ... poles 3 poles 4 poles rated current in a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 ... faz-c32/1 faz-c40/1 faz-c50/1 faz-c63/1 price faz-c1/2 type faz-c0,5/2 faz-c1,6/2 faz ...

for inductive loads response time of instantaneous trip 5 10 x in current ... rating ul recognized and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 ... type c characteristics suitable for applications where medium levels of inrush current ... are expected instantaneous trip is 5 to 10 ... x rating of device in applications include small transformers lighting ... pilot devices control circuits and coils medium magnetic trip point trip ... 3 poles neutral rated current in a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 ... c32/1n faz-c40/1n faz-c50/1n faz-c63/1n price type faz-c0,5/3n faz-c1/3n faz-c1,6/3n ...

highly inductive loads response time of instantaneous trip 10 20 x in current ... rating ul recognized and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 ... type d characteristics suitable for applications where high levels of inrush current are ... instantaneous trip is 10 to 20 x rating of device in the high magnetic trip point ... nuisance tripping in high inductive applications such as motors transformers and power ... poles 3 poles 4 poles rated current in a 6 8 10 13 16 20 25 32 40 faz-d6/1 faz- ... d8/1 type price faz-d6/2 faz-d8/2 type price faz-d6/3 faz-d8/3 type price faz-d6/4 ...

highly inductive loads response time of instantaneous trip 10 20 x in current ... rating ul recognized and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 ... type d characteristics suitable for applications where high levels of inrush current are ... instantaneous trip is 10 to 20 x rating of device in the high magnetic trip point ... nuisance tripping in high inductive applications such as motors transformers and power ... loads 3 poles neutral rated current in a 6 8 10 13 16 20 25 32 40 type faz-d6/3n ... d20/3n faz-d25/3n faz-d32/3n faz-d40/3n price see green pages 7200 3600 t [s 1.13 1. ...

k designed for motors transformers and upstream electronics response time of ... 8 12 x in current rating ul recognized and csa certified as supplementary ... protectors for international and domestic use conform to iec en60898 ... type k characteristics suitable for applications where high levels of inrush current are ... trip is 8 to 12 x continuous rating of device in the high magnetic trip point ... is ideal for motors and transformers the narrow range compared ... the type d curve makes it ideal for applications where nuisance tripping is not an issue ... k designed for motors transformers and upstream electronics 1 pole 2 poles 3 ... poles 4 poles rated current in a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 ...

k designed for motors transformers and upstream electronics response time of ... 8 12 x in current rating ul recognized and csa certified as supplementary ... protectors for international and domestic use conform to iec en60898 ... type k characteristics suitable for applications where high levels of inrush current are ... trip is 8 to 12 x continuous rating of device in the high magnetic trip point ... is ideal for motors and transformers the narrow range compared ... the type d curve makes it ideal for applications where nuisance tripping is not an issue ... k designed for motors transformers and upstream electronics 3 poles neutral ...

z designed for protection of electronic devices response time of ... 2 3 x in current rating ul recognized and csa certified as supplementary ... protectors for international and domestic use conform to iec en60898 ... type z characteristics suitable for applications where semiconductors and other ... components that fail open are used instantaneous trip is 2 to 3 x ... continuous rating of device in the short thermal delay and ... low magnetic trip point are ideal for applications where devices and components have low ... surge and short circuit tolerances trip characteristic z ... designed for protection of electronic devices 1 pole 2 poles 3 ...

s designed for control circuits with high inrush response time of ... 17 x in current rating ul recognized and csa certified as supplementary ... protectors for international and domestic use conform to iec en60898 ... type s characteristics suitable for applications with highly inductive loads especially ... in control circuits with coils and light filaments instantaneous response ... between 13 to 17 x rating of device in trip characteristic s ... designed for control circuits with high inrush 1 pole 2 poles rated ... current in a 1 2 3 4 6 10 16 20 25 32 40 faz-s1/1 ... -s2/1 faz-s3/1 faz-s4/1 faz-s6/1 type price faz-s1/2 faz-s2/2 faz-s3/2 faz-s4/2 ...

eemac ratings voltage ratings nema and eemac standards recognize that ... industrial control is normally applied to the point of power utilization and ... the nema standard industrial control and systems 1993 includes the following ... nema eemac sizes motor starters are sometimes referred to by their nema/ ... the nema standard industrial controls and systems -1993 ics 2-321.20 lists the ... for these sizes for non-plugging and non-jogging duty general information ... voltage ratings for industrial control apparatus are based on utilization voltages and ... shall be as follows a b c alternating current 60 hertz multiphase 115 200 ...